Heart Lung Circ ; 24(6): 611-3, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25697385

ABSTRACT

OBJECTIVE: We report the successful transplantation of a heart following an out-of-body time of 611 minutes into a recipient with dilated cardiomyopathy and left ventricular assist device implant. PATIENTS: Our patient was urgently waiting for a cardiac transplant whilst receiving LVAD support. Recurrent VF and repeated AICD shocks necessitated this action. RESULTS: Although requiring ECMO and inotropic support in the first 17 hours post-transplant, the patient was discharged from hospital on day 15 post-transplant with normal cardiac function. CONCLUSION: We report some of the salient points of the process and discuss the utility of this technology to an Australian transplant unit.


Subject(s)
Cardiomyopathy, Dilated/surgery , Heart Transplantation/methods , Organ Preservation/instrumentation , Tissue and Organ Procurement/methods , Adult , Cardiomyopathy, Dilated/diagnosis , Equipment Design , Heart-Assist Devices , Humans , Male , Organ Preservation/methods , Time Factors , Treatment Outcome