Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 13(3)2023 Feb 03.
Article in English | MEDLINE | ID: mdl-36766676

ABSTRACT

Background-There are conflicting data in the international literature on the risks of abnormal fetal growth in fetuses presenting an isolated single umbilical artery (SUA), and the pathophysiology of this complication is poorly understood. Objective-To evaluate if changes in diameter of the remaining umbilical artery in fetuses presenting an isolated SUA are associated with different fetal growth patterns. Study design-This was a two-center prospective longitudinal observational study including 164 fetuses diagnosed with a SUA at the 20-22-week detailed ultrasound examination and 200 control fetuses with a three-vessel cord. In all cases, the diameters of the cord vessels were measured in a transverse view of the central portion of the umbilical cord, and the number of cord vessels was confirmed at delivery. Logistic regression and nonparametric receiver operating characteristic (ROC) analysis were carried out to evaluate the association of the umbilical artery diameter in a single artery with small for-gestational age (SGA) and with fetal growth restriction (FGR). The impact of artery dimension was adjusted for maternal BMI, parity, ethnicity, side of the remaining umbilical artery and umbilical resistance index (RI) in the regression model. Results-A significantly (p < 0.001) larger mean diameter was found for the remaining artery in fetuses with SUA compared with controls (3.0 ± 0.9 vs. 2.5 ± 0.6 mm). After controlling for BMI and parity, we found no difference in umbilical resistance and side of the remaining umbilical artery between the SUA and control groups. A remaining umbilical artery diameter of >3.1 mm was found to be associated with a lower risk of FGR, but this association failed to be statistical significant (OR = 0.60, 95% CI = 0.33-1.09, p value = 0.089). We also found that the mean vein-to-artery area ratio was significantly (p < 0.001) increased in the SUA group as compared with the controls (2.4 ± 1.8 vs. 1.8 ± 0.9; mean difference = 0.6; Cohen's d = 0.46). Conclusion-In most fetuses with isolate SUA, the remaining artery diameter at 20-22 weeks is significantly larger than in controls. When there are no changes in the diameter and, in particular, if it remains <3.1 mm, the risk of abnormal fetal growth is higher, and measurements of the diameter of the remaining artery could be used to identify fetuses at risk of FGR later in pregnancy.

2.
J Matern Fetal Neonatal Med ; 35(22): 4299-4305, 2022 Nov.
Article in English | MEDLINE | ID: mdl-33203263

ABSTRACT

INTRODUCTION: Coarctation of the aorta (CoA) is common and can lead to neonatal emergency. Despite its burden, antenatal detection of this condition remains inaccurate. OBJECTIVE: To evaluate the diagnostic performance of fetal echocardiography and to design a scoring system for risk stratification of CoA in suspected cases. DESIGN: A retrospective cohort study. SETTING: S. Orsola Hospital, Bologna, Italy. POPULATION: About 140 fetuses referred for suspected CoA to our tertiary center in a 9-year period. METHODS: The following parameters were systematically obtained at fetal echocardiography: ventricular disproportion, great vessels asymmetry, transverse aortic arch hypoplasia, flow turbulence, and Z-scores of the ascending aorta and of the aortic isthmus. Associated anomalies were recorded, if present. When CoA was not confirmed at birth, neonates were followed up for 12 months to identify also a tardive onset of this condition. MAIN OUTCOME MEASURES: The primary outcome was the presence of COA after birth. RESULTS: 108 fetuses were eligible for the purpose of the study. CoA was confirmed postnatally in 55 neonates (50.9%). Arch hypoplasia yielded the highest correlation with CoA. The affected neonates presented also significantly lower Z scores of the ascending aorta and of the aortic isthmus. Earlier gestational age at referral was positively correlated with neonatal CoA. An odds ratio-based multiparametric model was designed to build a scoring system (AUC 0.89). CONCLUSION: In our cohort, no single ultrasound parameter was sufficiently accurate to predict postnatal CoA. The scoring system permitted a better identification of the affected fetuses.


Subject(s)
Aortic Coarctation , Aorta , Aortic Coarctation/diagnostic imaging , Echocardiography , Female , Humans , Infant, Newborn , Pregnancy , Retrospective Studies , Ultrasonography, Prenatal
3.
Diagnostics (Basel) ; 11(11)2021 Nov 02.
Article in English | MEDLINE | ID: mdl-34829373

ABSTRACT

INTRODUCTION: The objective of this randomized controlled study was to demonstrate whether acoustic stimulation in utero is associated with fetal reactivity which is documentable by cardiotocography. MATERIALS AND METHODS: A monocentric randomized controlled trial was performed at a single university tertiary hospital between September 2016 and July 2017. This study was registered as a randomized clinical trial on clinicaltrail.gov (registration number NCT04622059). Unselected pregnancies at term of gestation were consecutively recruited for the purpose of this study. After 10 min of normal cardiotocography without accelerations (non-stress-test with a basal frequency between 110 and 150 beats/min, normal variability between 6 and 15 b/min, no accelerations, and no fetal movements), fetuses were randomized at a 1:1 ratio to either of the two groups. Fetuses in group A (n = 105) received acoustic stimulation after 10 min from the beginning of the CTG, whereas fetuses in group B received no stimulation (n = 105). The outcome variables investigated were the lapse of time between the beginning of the CTG and the occurrence of the first acceleration, and the lapse of time between the beginning of the CTG and the first fetal movement noticed. RESULTS: The lapse of time between the beginning of the CTG and the occurrence of the first acceleration was significantly shorter in the group with acoustic stimulation compared to the other group (14.87 ± 5.01 vs. 21.90 ± 6.94 min, p-value < 0.001 log-rank test). Similarly, the lapse of time between the beginning of the CTG and the occurrence of the first fetal movement was significantly shorter in group A compared to group B (17.77 ± 7.62 vs. 23.28 ± 7.61 min, p-value < 0.001, log-rank test). Fetal cardiac acceleration and the occurrence of a fetal movement during the first 20 min of the CTG were more frequently recorded in group A compared to group B (respectively, 15% vs. 5% and 20% vs. 8%). CONCLUSION: This RCT showed an early fetal reaction following auditive stimulus, documentable by cardiotocography. Further research is needed to investigate a possible role of acoustic stimulation in utero for the prenatal diagnosis of congenital hypoacusis.

4.
Diagnostics (Basel) ; 11(5)2021 May 12.
Article in English | MEDLINE | ID: mdl-34065897

ABSTRACT

BACKGROUND: developmental dysplasia of the hip has an incidence of 3-5 out of 1000 children. Currently, only postnatal screening is available. OBJECTIVE: to test the feasibility of a method based on Graf technique application at antenatal ultrasound in assessing the normal development of the hip in unselected term fetuses. METHODS: a prospective cohort study in a single university tertiary hospital from January 2017 to January 2020. Single uncomplicated term pregnancies (37-40 weeks) attending our center for routine ultrasound were consecutively recruited for the purpose of the study. A 3D volume acquisition was launched on the coxofemoral joint of the fetus by a single expert operator, and offline analysis was then performed in the multiplanar mode by two operators (blinded to each other analysis) in order to measure the alpha and beta angles according to our modified Graf technique. Intra- and inter-observer variations were calculated. Reference charts for normal values of both angles were produced. Postnatal ultrasound was then performed to measure the Graf angles in newborns, confirming a normal development of the hip. RESULTS: in the study period, 433 uncomplicated term pregnancies underwent 3D ultrasound for the assessment of the fetal hip. One case was subsequently excluded because of confirmed postnatal diagnosis of developmental dysplasia of the hip. The measurement of our modified Graf angles was feasible at prenatal ultrasound with a good reproducibility. The inter-rater and intra-rater reliability of both angles was substantial. Reference charts for normal values of both angles were produced. CONCLUSIONS: the evaluation of the coxofemoral joint in fetuses at term of gestation has never been attempted before. The Graf technique application, currently employed at postnatal ultrasound, may also be adapted to prenatal ultrasound with a substantial reproducibility. However, there was no evidence of a linear relationship between prenatal and postnatal alpha angles and beta angles. Further research is needed to establish if developmental dysplasia of the hip could be diagnosed antenatally.

5.
Am J Obstet Gynecol MFM ; 3(5): 100379, 2021 09.
Article in English | MEDLINE | ID: mdl-33965655

ABSTRACT

BACKGROUND: Hypoxia caused by inadequate intracardiac mixing owing to a restrictive foramen ovale is a potentially life-threatening complication in neonates with dextro-transposition of the great arteries. An urgent balloon atrial septostomy is a procedure of choice in such cases, but dependent on the availability of a 24-hour interventional cardiology facility. The prenatal identification of predictors for an urgent balloon atrial septostomy at birth would help in optimizing the management of these neonates, minimizing the risk of hypoxic damage. OBJECTIVE: This study aimed to predict with prenatal echocardiography the need of urgent balloon atrial septostomy in neonates with dextro-transposition of the great arteries. STUDY DESIGN: This was a retrospective cohort study of patients with a prenatal diagnosis of transposition of the great arteries that were delivered in our center between 2010 and 2019, for whom fetal ultrasound echocardiograms obtained at less than 3 weeks before delivery were available. The following parameters were systematically obtained at fetal echocardiography: size and appearance of the foramen ovale, septum primum excursion (foramen ovale flap angle at the maximal excursion), diameters of the atria, and size of the ductus arteriosus. Balloon atrial septostomy was defined as urgent if performed within 12 hours from birth in neonates with restrictive foramen ovale. Neonatal follow-up was obtained through medical records analysis. RESULTS: From November 2007 to April 2019, 160 fetuses with complete transposition of the great arteries were referred to our echocardiography laboratory and 60 of these were included in the analysis; 27 underwent urgent balloon atrial septostomy, 11 elective balloon atrial septostomy, and 22 no balloon atrial septostomy. The size of the foramen ovale was the best predictor of an urgent balloon atrial septostomy. A measurement of >6.5 mm had a sensitivity of 100% and a false positive rate of 45%. CONCLUSION: Fetal echocardiography predicts the need of an urgent balloon atrial septostomy in fetuses with dextro-transposition of the great arteries although with a limited precision. In our experience, a measurement of the foramen ovale within 3 weeks of delivery had the greatest accuracy.


Subject(s)
Foramen Ovale , Transposition of Great Vessels , Arteries , Female , Foramen Ovale/diagnostic imaging , Humans , Infant, Newborn , Pregnancy , Retrospective Studies , Transposition of Great Vessels/diagnostic imaging , Ultrasonography, Prenatal
SELECTION OF CITATIONS
SEARCH DETAIL
...