Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Heart Lung Transplant ; 33(4): 422-8, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24388396

ABSTRACT

BACKGROUND: Minimally invasive techniques are desirable to minimize surgical trauma during left ventricular assist device (LVAD) implantation. This is particularly challenging for full-flow support. In this study, a minimally invasive implantation technique was developed for a microaxial rotary pump. The system was evaluated in a chronic sheep model. METHODS: A HeartWare MVAD (HeartWare, Miami Lakes, FL) pump (length, 50 mm; diameter, 21 mm; maximum flow, 7-8 liters/min) was combined with a novel inflow cannula, including a new flow-optimized tip. The device was implanted into sheep (range, 60-80 kg, mean, 71.6 ± 6.8 kg) through a right-sided minithoracotomy. The inflow cannula was inserted through the superior pulmonary vein, passing through the left atrium into the left ventricle. Scheduled implant period was 30 days for 8 sheep and 100 days for 3 sheep. Mean support flow was set to half of the nominal cardiac output. RESULTS: Six of 8 sheep finished the scheduled 30-day investigation period (one failed due to early non-pump-related post-operative bleeding and one due to prototype controller failure). The 3 sheep scheduled for 100 days reached the study end point. Peak pump flows of up to 6.9 liters/min were achieved. At necropsy, no signs of mitral valve lesions or thrombus formation around the cannula, the tip, or the insertion site were observed, except for valve leaflet erosion in 1 animal, where the cannula had been entangled in the sub-valvular chords due to lack of ultrasound monitoring. CONCLUSIONS: The minimally invasive implantation technique using the HeartWare MVAD pump, together with a new cannula, provided excellent results in a chronic animal model.


Subject(s)
Heart-Assist Devices , Miniaturization , Minimally Invasive Surgical Procedures , Prosthesis Design , Animals , Catheters , Equipment Failure Analysis , Female , Heart Atria/pathology , Heart Atria/surgery , Hemodynamics/physiology , Humans , Materials Testing , Mitral Valve/pathology , Mitral Valve/surgery , Sheep , Thoracotomy
2.
J Thorac Cardiovasc Surg ; 142(3): 668-74, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21320708

ABSTRACT

BACKGROUND: Left ventricular assist devices are increasingly used to treat patients with advanced and otherwise refractory heart failure as bridge to transplant or destination therapy. We evaluated a new miniaturized left ventricular assist device that requires minimal surgery for implantation, potentially allowing implantation in earlier stage heart failure. METHODS: HeartWare (Miami Lakes, Fla) developed transapical miniaturized ventricular assist device. Acute (n = 4), 1-week (n = 2), and 30-day (n = 4) bovine model experiments evaluated hemodynamic efficacy and biocompatibility of the device, which was implanted through small left thoracotomy with single insertion at apex of left ventricle without cardiopulmonary bypass. The device outflow cannula was positioned across the aortic valve. The international normalized ratio was maintained between 2.0 and 2.5 with warfarin. Hemodynamic, echocardiographic, fluoroscopic, hematologic, and blood chemistry measurements were evaluated. RESULTS: The device was successfully implanted through the left ventricular apex in all 10 animals. The device was operated at 15,000 ± 1000 rpm (power consumption, 3.5-6.0 W). The device maintained normal end-organ perfusion with no significant hemolysis (0-30 mg/dL). There were no pump failures or device-related complications. At autopsy, no abnormalities were seen in endocardium, aortic valve leaflets, or aortic root. There was no evidence of thromboembolism or abnormalities in any peripheral end organs. CONCLUSIONS: We successfully demonstrated feasibility of a novel intraventricular assist device that can be completely implanted through left ventricular apex. This transapical surgical approach eliminates needs for sternotomy, device pocket, cardiopulmonary bypass, ventricular coring, and construction of an outflow graft anastomosis.


Subject(s)
Heart-Assist Devices , Prosthesis Implantation/methods , Animals , Cattle , Equipment Design , Heart Ventricles , Male , Miniaturization , Models, Animal
SELECTION OF CITATIONS
SEARCH DETAIL
...