Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Transplant Direct ; 10(7): e1664, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38953041

ABSTRACT

Background: Ex situ machine perfusion is increasingly used to preserve and assess donor livers before transplantation. Compared with traditional static cold storage (SCS), machine perfusion exposes livers to an additional risk of microbial contamination. However, information on the risk of microbial transmission during machine perfusion is lacking. Methods: All livers that underwent either hypothermic oxygenated machine perfusion (HOPE) or normothermic machine perfusion (NMP) in our center between September 2021 and September 2023, and during which samples were taken from SCS fluid and/or machine perfusion solution for microbiological examination, were included in this retrospective, observational clinical study. Microbial transmission was examined from SCS fluid to machine perfusion solution fluid and, subsequently, to recipients of these livers. Results: A total of 90 cases of liver machine perfusion were included: 59 HOPE and 31 NMP. SCS preservation fluid cultures before HOPE or NMP were positive for at least 1 microorganism in 52% of the cases. After HOPE, there were no cases of positive machine perfusion fluid or evidence of microbial transmission to the recipients. After NMP, in 1 (3%) patient Escherichia coli was grown from abdominal drain fluid, the same bacterial strain that was also grown from the SCS preservation fluid before NMP. This E coli was resistant to the antibiotics that are routinely added to the NMP perfusion fluid. Conclusions: The risk of microbial transmission after machine perfusion is very low but not absent. We recommend routine sampling of machine perfusion fluid at the end of the procedure for microbiological analysis.

3.
EClinicalMedicine ; 68: 102411, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38235423

ABSTRACT

Background: Liver transplantation is traditionally performed around the clock to minimize organ ischemic time. However, the prospect of prolonging preservation times holds the potential to streamline logistics and transform liver transplantation into a semi-elective procedure, reducing the need for nighttime surgeries. Dual hypothermic oxygenated machine perfusion (DHOPE) of donor livers for 1-2 h mitigates ischemia-reperfusion injury and improves transplant outcomes. Preclinical studies have shown that DHOPE can safely extend the preservation of donor livers for up to 24 h. Methods: We conducted an IDEAL stage 2 prospective clinical trial comparing prolonged (≥4 h) DHOPE to conventional (1-2 h) DHOPE for brain-dead donor livers, enabling transplantation the following morning. Liver allocation to each group was based on donor hepatectomy end times. The primary safety endpoint was a composite of all serious adverse events (SAE) within 30 days after transplantation. The primary feasibility endpoint was defined as the number of patients assigned and successfully receiving a prolonged DHOPE-perfused liver graft. Trial registration at: WHO International Clinical Trial Registry Platform, number NL8740. Findings: Between November 1, 2020 and July 16, 2022, 24 patients were enrolled. The median preservation time was 14.5 h (interquartile range [IQR], 13.9-15.5) for the prolonged group (n = 12) and 7.9 h (IQR, 7.6-8.6) for the control group (n = 12; p = 0.01). In each group, three patients (25%; 95% CI 3.9-46%, p = 1) experienced a SAE. Markers of ischemia-reperfusion injury and oxidative stress in both perfusate and recipients were consistently low and showed no notable discrepancies between the two groups. All patients assigned to either the prolonged group or control group successfully received a liver graft perfused with either prolonged DHOPE or control DHOPE, respectively. Interpretation: This first-in-human clinical trial demonstrates the safety and feasibility of DHOPE in prolonging the preservation time of donor livers to enable daytime transplantation. The ability to extend the preservation window to up to 20 h using hypothermic oxygenated machine preservation at a 10 °C temperature has the potential to reshape the landscape of liver transplantation. Funding: University Medical Center Groningen, the Netherlands.

4.
Transplant Direct ; 10(2): e1568, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38274473

ABSTRACT

Background: Normothermic machine perfusion (NMP) is used to preserve and test donor livers before transplantation. During NMP, the liver is metabolically active and produces waste products, which are released into the perfusate. In this study, we describe our simplified and inexpensive setup that integrates continuous renal replacement therapy (CRRT) with NMP for up to 7 d. We also investigated if the ultrafiltrate could be used for monitoring perfusate concentrations of small molecules such as glucose and lactate. Methods: Perfusate composition (urea, osmolarity, sodium, potassium, chloride, calcium, magnesium, phosphate, glucose, and lactate) was analyzed from 56 human NMP procedures without CRRT. Next, in 6 discarded human donor livers, CRRT was performed during NMP by integrating a small dialysis filter (0.2 m2) into the circuit to achieve continuous ultrafiltration combined with continuous fluid substitution for up to 7 d. Results: Within a few hours of NMP without CRRT, a linear increase in osmolarity and concentrations of urea and phosphate to supraphysiological levels was observed. After integration of CRRT into the NMP circuit, the composition of the perfusate was corrected to physiological values within 12 h, and this homeostasis was maintained during NMP for up to 7 d. Glucose and lactate levels, as measured in the CRRT ultrafiltrate, were strongly correlated with perfusate levels (r = 0.997, P < 0.001 and r = 0.999, P < 0.001, respectively). Conclusions: The integration of CRRT into the NMP system corrected the composition of the perfusate to near-physiological values, which could be maintained for up to 7 d. The ultrafiltrate can serve as an alternative to the perfusate to monitor concentrations of small molecules without potentially compromising sterility.

5.
Nat Commun ; 14(1): 7880, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38036513

ABSTRACT

Normothermic machine perfusion (NMP) after static cold storage is increasingly used for preservation and assessment of human donor livers prior to transplantation. Biliary viability assessment during NMP reduces the risk of post-transplant biliary complications. However, understanding of molecular changes in the biliary system during NMP remains incomplete. We performed an in-depth, unbiased proteomics analysis of bile collected during sequential hypothermic machine perfusion, rewarming and NMP of 55 human donor livers. Longitudinal analysis during NMP reveals proteins reflective of cellular damage at early stages, followed by upregulation of secretory and immune response processes. Livers with bile chemistry acceptable for transplantation reveal protein patterns implicated in regenerative processes, including cellular proliferation, compared to livers with inadequate bile chemistry. These findings are reinforced by detection of regenerative gene transcripts in liver tissue before machine perfusion. Our comprehensive bile proteomics and liver transcriptomics data sets provide the potential to further evaluate molecular mechanisms during NMP and refine viability assessment criteria.


Subject(s)
Biliary Tract , Liver Transplantation , Humans , Bile/metabolism , Proteome/metabolism , Living Donors , Liver , Perfusion
6.
Thromb Res ; 228: 64-71, 2023 08.
Article in English | MEDLINE | ID: mdl-37290373

ABSTRACT

BACKGROUND: Normothermic machine perfusion (NMP) of donor livers allows for new diagnostic and therapeutic strategies. As the liver produces most of the haemostatic proteins, coagulation assays such as the International Normalised Ratio (INR) performed in perfusate may be useful to assess hepatocellular function of donor livers undergoing NMP. However, high concentrations of heparin and low levels of fibrinogen may affect coagulation assays. METHODS: Thirty donor livers that underwent NMP were retrospectively included in this study, of which 18 were subsequently transplanted. We measured INRs in perfusate in presence or absence of exogenously added fibrinogen and/or polybrene. Additionally, we prospectively included 14 donor livers that underwent NMP (of which 11 were transplanted) and measured INR using both a laboratory coagulation analyser and a point-of-care device. RESULTS: In untreated perfusate samples, the INR was above the detection limit in all donor livers. Addition of both fibrinogen and polybrene was required for adequate INR assessment. INRs decreased over time and detectable perfusate INR values were found in 17/18 donor livers at the end of NMP. INR results were similar between the coagulation analyser and the point-of-care device, but did not correlate with established hepatocellular viability criteria. CONCLUSIONS: Most of the donor livers that were transplanted showed a detectable perfusate INR at the end of NMP, but samples require processing to allow for INR measurements using laboratory coagulation analysers. Point-of-care devices bypass this need for processing. The INR does not correlate with established viability criteria and might therefore have additional predictive value.


Subject(s)
Liver Transplantation , Humans , Liver Transplantation/methods , International Normalized Ratio , Hexadimethrine Bromide/metabolism , Retrospective Studies , Organ Preservation/methods , Living Donors , Liver/metabolism , Perfusion/methods , Blood Coagulation Factors/metabolism , Fibrinogen/metabolism
7.
Transplantation ; 107(11): 2377-2383, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37291723

ABSTRACT

BACKGROUND: Normothermic machine perfusion (NMP) is used for the viability assessment of high-risk donor livers before transplantation. The production of hemostatic proteins is one of the major synthetic functions of the liver. The objective of this study was to measure the concentration and functionality of hemostatic proteins concentration in the NMP perfusate of human donor livers. METHODS: Thirty-six livers that underwent NMP for viability assessment were included in this study. Perfusate samples taken during NMP (start, 150 min, and 300 min) were used for the measurement of antigen and activity levels of hemostatic proteins (factors II, VII, and X; fibrinogen; plasminogen; antithrombin; tissue plasminogen activator; von Willebrand factor; and proteins induced by vitamin K absence). The antigen levels were correlated with hepatocellular function according to previously proposed individual hepatocellular viability criteria: lactate clearance and perfusate pH. RESULTS: Antigen levels of hemostatic proteins reached subphysiological levels in the NMP perfusate. Hemostatic proteins that were produced during NMP were at least partially active. All livers produced all hemostatic proteins tested within 150 min of NMP. Hemostatic protein concentrations did not significantly correlate with perfusate lactate and perfusate pH after 150 min of NMP. CONCLUSIONS: All livers produce functional hemostatic proteins during NMP. The generation of a functional hemostatic system in NMP perfusate confirms the need for adequate anticoagulation of the perfusate to avoid generation of (micro)thrombi that may harm the graft.

8.
Transplantation ; 107(6): e161-e172, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36721302

ABSTRACT

BACKGROUND: End-ischemic ex situ normothermic machine perfusion (NMP) enables assessment of donor livers prior to transplantation. The objective of this study was to provide support for bile composition as a marker of biliary viability and to investigate whether bile ducts of high-risk human donor livers already undergo repair during NMP. METHODS: Forty-two livers that were initially declined for transplantation were included in our NMP clinical trial. After NMP, livers were either secondary declined (n = 17) or accepted for transplantation (n = 25) based on the chemical composition of bile and perfusate samples. Bile duct biopsies were taken before and after NMP and assessed using an established histological injury severity scoring system and a comprehensive immunohistochemical assessment focusing on peribiliary glands (PBGs), vascular damage, and regeneration. RESULTS: Bile ducts of livers that were transplanted after viability testing during NMP showed better preservation of PBGs, (micro)vasculature, and increased cholangiocyte proliferation, compared with declined livers. Biliary bicarbonate, glucose, and pH were confirmed as accurate biomarkers of bile duct vitality. In addition, we found evidence of PBG-based progenitor cell differentiation toward mature cholangiocytes during NMP. CONCLUSIONS: Favorable bile chemistry during NMP correlates well with better-preserved biliary microvasculature and PBGs, with a preserved capacity for biliary regeneration. During NMP, biliary tree progenitor cells start to differentiate toward mature cholangiocytes, facilitating restoration of the ischemically damaged surface epithelium.


Subject(s)
Bile Duct Diseases , Liver Transplantation , Humans , Living Donors , Liver/pathology , Bile Ducts/metabolism , Perfusion , Bile Duct Diseases/pathology , Organ Preservation
9.
J Hepatol ; 77(3): 825-836, 2022 09.
Article in English | MEDLINE | ID: mdl-35533801

ABSTRACT

Liver transplantation has become an immense success; nevertheless, far more recipients are registered on waiting lists than there are available donor livers for transplantation. High-risk, extended criteria donor livers are increasingly used to reduce the discrepancy between organ demand and supply. Especially for high-risk livers, dynamic preservation using machine perfusion can decrease post-transplantation complications and may increase donor liver utilisation by improving graft quality and enabling viability testing before transplantation. To further increase the availability of donor livers suitable for transplantation, new strategies are required that make it possible to use organs that are initially too damaged to be transplanted. With the current progress in experimental liver transplantation research, (long-term) normothermic machine perfusion may be used in the future as a dynamic platform for regenerative medicine approaches, enabling repair and regeneration of injured donor livers. Currently explored therapeutics such as defatting cocktails, RNA interference, senolytics, and stem cell therapy may assist in the repair and/or regeneration of injured livers before transplantation. This review will provide a forecast of the future utility of normothermic machine perfusion in decreasing the imbalance between donor liver demand and supply by enabling the repair and regeneration of damaged donor livers.


Subject(s)
Liver Transplantation , Organ Preservation , Humans , Liver , Living Donors , Perfusion
10.
Am J Transplant ; 22(6): 1658-1670, 2022 06.
Article in English | MEDLINE | ID: mdl-35286759

ABSTRACT

Ex situ normothermic machine perfusion (NMP) is increasingly used for viability assessment of high-risk donor livers, whereas dual hypothermic oxygenated machine perfusion (DHOPE) reduces ischemia-reperfusion injury. We aimed to resuscitate and test the viability of initially-discarded, high-risk donor livers using sequential DHOPE and NMP with two different oxygen carriers: an artificial hemoglobin-based oxygen carrier (HBOC) or red blood cells (RBC). In a prospective observational cohort study of 54 livers that underwent DHOPE-NMP, the first 18 procedures were performed with a HBOC-based perfusion solution and the subsequent 36 procedures were performed with an RBC-based perfusion solution for the NMP phase. All but one livers were derived from extended criteria donation after circulatory death donors, with a median donor risk index of 2.84 (IQR 2.52-3.11). After functional assessment during NMP, 34 livers (63% utilization), met the viability criteria and were transplanted. One-year graft and patient survival were 94% and 100%, respectively. Post-transplant cholangiopathy occurred in 1 patient (3%). There were no significant differences in utilization rate and post-transplant outcomes between the HBOC and RBC group. Ex situ machine perfusion using sequential DHOPE-NMP for resuscitation and viability assessment of high-risk donor livers results in excellent transplant outcomes, irrespective of the oxygen carrier used.


Subject(s)
Liver Transplantation , Hemoglobins , Humans , Liver , Liver Transplantation/methods , Living Donors , Organ Preservation/methods , Oxygen , Perfusion/methods , Prospective Studies
11.
Am J Physiol Gastrointest Liver Physiol ; 322(2): G183-G200, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34756122

ABSTRACT

Although short-term machine perfusion (≤24 h) allows for resuscitation and viability assessment of high-risk donor livers, the donor organ shortage might be further remedied by long-term perfusion machines. Extended preservation of injured donor livers may allow reconditioning, repairing, and regeneration. This review summarizes the necessary requirements and challenges for long-term liver machine preservation, which requires integrating multiple core physiological functions to mimic the physiological environment inside the body. A pump simulates the heart in the perfusion system, including automatically controlled adjustment of flow and pressure settings. Oxygenation and ventilation are required to account for the absence of the lungs combined with continuous blood gas analysis. To avoid pressure necrosis and achieve heterogenic tissue perfusion during preservation, diaphragm movement should be simulated. An artificial kidney is required to remove waste products and control the perfusion solution's composition. The perfusate requires an oxygen carrier, but will also be challenged by coagulation and activation of the immune system. The role of the pancreas can be mimicked through closed-loop control of glucose concentrations by automatic injection of insulin or glucagon. Nutrients and bile salts, generally transported from the intestine to the liver, have to be supplemented when preserving livers long term. Especially for long-term perfusion, the container should allow maintenance of sterility. In summary, the main challenge to develop a long-term perfusion machine is to maintain the liver's homeostasis in a sterile, carefully controlled environment. Long-term machine preservation of human livers may allow organ regeneration and repair, thereby ultimately solving the shortage of donor livers.


Subject(s)
Liver Transplantation , Liver , Organ Preservation , Time Factors , Homeostasis/physiology , Humans , Liver/metabolism , Liver Transplantation/methods , Organ Preservation/methods , Organ Preservation Solutions , Perfusion
12.
Int J Mol Sci ; 22(1)2020 Dec 28.
Article in English | MEDLINE | ID: mdl-33379394

ABSTRACT

Oxygenated ex situ machine perfusion of donor livers is an alternative for static cold preservation that can be performed at temperatures from 0 °C to 37 °C. Organ metabolism depends on oxygen to produce adenosine triphosphate and temperatures below 37 °C reduce the metabolic rate and oxygen requirements. The transport and delivery of oxygen in machine perfusion are key determinants in preserving organ viability and cellular function. Oxygen delivery is more challenging than carbon dioxide removal, and oxygenation of the perfusion fluid is temperature dependent. The maximal oxygen content of water-based solutions is inversely related to the temperature, while cellular oxygen demand correlates positively with temperature. Machine perfusion above 20 °C will therefore require an oxygen carrier to enable sufficient oxygen delivery to the liver. Human red blood cells are the most physiological oxygen carriers. Alternative artificial oxygen transporters are hemoglobin-based oxygen carriers, perfluorocarbons, and an extracellular oxygen carrier derived from a marine invertebrate. We describe the principles of oxygen transport, delivery, and consumption in machine perfusion for donor livers using different oxygen carrier-based perfusion solutions and we discuss the properties, advantages, and disadvantages of these carriers and their use.


Subject(s)
Erythrocytes/metabolism , Liver/metabolism , Oxygen/metabolism , Perfusion , Animals , Humans , Temperature , Tissue Donors
13.
J Clin Anesth ; 39: 89-95, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28494917

ABSTRACT

STUDY OBJECTIVE: The present study aimed to validate the Nexfin® monitor and to assess the accuracy compared to classical sphygmomanometry (Riva-Rocci/Korotkoff (RRK)) blood pressure (BP) measurements in patients with obesity scheduled for bariatric surgery. DESIGN: Validation study. SETTING: Outpatient clinic for bariatric surgery. PATIENTS: 33 patients scheduled for bariatric surgery. MEASUREMENTS: The validation process was done according to the protocols developed by the European Society of Hypertension from 2010. The Nexfin® monitor (Edwards Lifesciences/BMEYE B.V., Amsterdam, The Netherlands) calculates beat-to-beat blood pressure from finger pulse wave analysis. Measurements of systolic and diastolic BP were obtained using classical sphygmomanometry and the Nexfin® alternatingly. MAIN RESULTS: In total 99 pairs of BP measurements were used. The device failed pass phase 1 as 65 systolic readings fell within 5mmHg (73 required). And 61, 76 and 90 diastolic readings fell within 5, 10 and 15mmHg respectively. Finally, it failed to pass phase 2 as 23 patients for systolic and 25 for diastolic had at least 2/3 of their comparisons falling within 5mmHg (24 required) but 10 subjects for systolic and 8 for diastolic had all three comparisons more than 5mmHg different from the RRK readings (zero allowed). Mean differences were 7.8±6.9mmHg for SBP and 8.0±7.2mmHg for DBP. CONCLUSION: Using the revised protocol, the Nexfin® device was not able to pass validation. However using the original protocol, the Nexfin® device passed phase 1 and 2.1 of the validation process and failed to pass phase 2.2.


Subject(s)
Bariatric Surgery/methods , Blood Pressure Determination/methods , Blood Pressure , Obesity/surgery , Adult , Blood Pressure Determination/instrumentation , Humans , Middle Aged , Netherlands , Reproducibility of Results , Sphygmomanometers
14.
Obes Surg ; 27(7): 1835-1841, 2017 07.
Article in English | MEDLINE | ID: mdl-28138898

ABSTRACT

BACKGROUND: Compared to healthy individuals, obese have significantly higher systolic and diastolic blood pressure, mean arterial pressure, heart rate, and cardiac output. The aim of this study was to evaluate cardiovascular hemodynamic changes before and 3 months after bariatric surgery. METHODS: Patients scheduled for bariatric surgery between the 29th of September 2016 and 24th of March 2016 were included and compared with 24 healthy individuals. Hemodynamic measurements were performed preoperatively and 3 months after surgery, using the Nexfin® non-invasive continuous hemodynamic monitoring device (Edwards Lifesciences/BMEYE B.V., Amsterdam, the Netherlands). RESULTS: Eighty subjects were included in this study, respectively, 56 obese patients scheduled for bariatric surgery and 24 healthy individuals. Baseline hemodynamic measurements showed significant differences in cardiac output (6.5 ± 1.6 versus 5.7 ± 1.6 l/min, p = 0.046), mean arterial pressure (107 ± 19 versus 89 ± 11 mmHg, p = 0.001), systolic (134 ± 24 versus 116 ± 18 mmHg, p = 0.001) and diastolic blood pressure (89 ± 17 versus 74 ± 10 mmHg, p = 0.001), and heart rate (87 ± 12 versus 76 ± 14 bpm, p = 0.02) between obese and healthy subjects. Three months after surgery, significant changes occurred in mean arterial pressure (89 ± 17 mmHg, p = 0.001), systolic (117 ± 24 mmHg, p = 0.001) and diastolic blood pressure (71 ± 15 mmHg, p = 0.001), stroke volume (82.2 ± 22.4 ml, p = 0.03), and heart rate (79 ± 17 bpm, p = 0.02) CONCLUSIONS: Three months after bariatric surgery, significant improvements occur in hemodynamic variables except cardiac output and cardiac index, in the patient group.


Subject(s)
Hemodynamics/physiology , Monitoring, Physiologic/instrumentation , Obesity, Morbid/physiopathology , Weight Loss/physiology , Adult , Arterial Pressure/physiology , Bariatric Surgery/methods , Blood Pressure/physiology , Cardiac Output/physiology , Comorbidity , Female , Heart Rate/physiology , Humans , Male , Middle Aged , Monitoring, Ambulatory/instrumentation , Obesity, Morbid/surgery , Pilot Projects , Preoperative Care/instrumentation
15.
Respir Med ; 117: 73-80, 2016 08.
Article in English | MEDLINE | ID: mdl-27492516

ABSTRACT

Obesity is an increasing problem worldwide. The number of people with obesity doubled since the 1980's to affect an estimated 671 million people worldwide. Obese patients in general have an altered respiratory physiology and can have an impaired lung function, which leads to an increased risk of developing pulmonary complications during anaesthesia and after bariatric surgery (approximately 8%). Therefore the respiratory management of the bariatric surgical patient provides a number of challenges. This review will focus on the perioperative respiratory care in bariatric surgical patients discussing respiratory physiology in the obese and perioperative respiratory care in bariatric surgery. Finally the value of preoperative pulmonary function testing and preoperative OSAS screening will be discussed.


Subject(s)
Anesthesia/adverse effects , Bariatric Surgery/adverse effects , Lung/physiopathology , Obesity/therapy , Perioperative Care , Respiratory Physiological Phenomena/drug effects , Respiratory Therapy/methods , Bariatric Surgery/methods , Female , Humans , Male , Obesity/complications , Obesity/epidemiology , Obesity/surgery , Postoperative Complications/prevention & control , Respiratory Function Tests/methods , Tuberculosis, Pulmonary/chemically induced
SELECTION OF CITATIONS
SEARCH DETAIL
...