Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Spectrosc ; 63(9): 1081-8, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19796493

ABSTRACT

Laser-induced breakdown spectroscopy (LIBS) is an emerging analytical technique to perform elemental analysis in natural samples independent of their physical state (solid, liquid, or gaseous). Due to its instrumental features, LIBS shows promising potential to perform analysis in situ and in environments at risk. Since the analytical performance of LIBS strongly depends on the choice of experimental conditions, each particular application needs a specific instrumental adjustment. The present study evaluated three LIBS instrumental parameters regarding their influences on signal-to-noise ratio (SNR) of seven elements in soil samples: laser pulse energy, delay time, and integration time gate. A multivariate technique was used due to the significant interaction among the evaluated parameters. Subsequently, to optimize LIBS parameters for each individual element response, a method for multiple response optimization was used. With only one simple screening design, it was possible to obtain a good combination among the studied parameters in order to simultaneously increase the SNR for all analytes. Moreover, the analysis of individual response for elements is helpful to understand their physical behavior in the plasma and also how they are embedded in the sample matrix.

2.
Anal Chim Acta ; 575(2): 230-5, 2006 Aug 11.
Article in English | MEDLINE | ID: mdl-17723596

ABSTRACT

A microscopic laser-induced breakdown spectrometer was used to evaluate the analytical matrix effect commonly observed in the analysis of geological materials. Samples were analyzed in either the powder or pressed pellet forms. Calibration curves of a number of iron and aluminum compounds showed a linear relationship between the elemental concentration and peak intensity. A direct determination of elemental content can thus be made from extrapolation on these calibration curves. To investigate matrix effects, synthetic model samples were prepared from various iron and aluminum compounds spiked with SiO2 and CaCO3. The addition of these matrices had a pronounced analytical effect on those compounds prepared as pressed pellets. However, results indicated the absence of matrix effects when the samples were presented to the laser as loose powders on tape and results were compared to certified values, indicating the reliability of this approach for accurate analysis, provided the sample particle diameters are greater than approximately 100 microm. Finally, the simultaneous analysis of two different elements was demonstrated using powders on tape.

SELECTION OF CITATIONS
SEARCH DETAIL
...