Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 157
Filter
1.
J Clin Med ; 13(5)2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38592019

ABSTRACT

Background: Few data exist on the comparative long-term outcomes of severe aortic stenosis (AS) patients with different flow-gradient patterns undergoing transcatheter aortic valve implantation (TAVI). This study sought to evaluate the impact of the pre-TAVI flow-gradient pattern on long-term clinical outcomes after TAVI and assess changes in the left ventricular ejection fraction (LVEF) of different subtypes of AS patients following TAVI. Methods: Consecutive patients with severe AS undergoing TAVI in our institution were screened and prospectively enrolled. Patients were divided into four subgroups according to pre-TAVI flow/gradient pattern: (i) low flow-low gradient (LF-LG): stroke volume indexed (SVi) ≤ 35 mL/m2 and mean gradient (MG) < 40 mmHg); (ii) normal flow-low gradient (NF-LG): SVi > 35 mL/m2 and MG < 40 mmHg; (iii) low flow-high gradient (LF-HG): Svi 35 mL/m2 and MG ≥ 40 mmHg and (iv) normal flow-high gradient (NF-HG): SVi > 35 mL/m2 and MG ≥ 40 mmHg. Transthoracic echocardiography was repeated at 1-year follow-up. Clinical follow-up was obtained at 12 months, and yearly thereafter until 5-year follow-up was complete for all patients. Results: A total of 272 patients with complete echocardiographic and clinical follow-up were included in our analysis. Their mean age was 80 ± 7 years and the majority of patients (N = 138, 50.8%) were women. 62 patients (22.8% of the study population) were distributed in the LF-LG group, 98 patients (36%) were LF-HG patients, 95 patients (34.9%) were NF-HG, and 17 patients (6.3%) were NF-LG. There was a greater prevalence of comorbidities among LF-LG AS patients. One-year all-cause mortality differed significantly between the four subgroups of AS patients (log-rank p: 0.022) and was more prevalent among LF-LG patients (25.8%) compared to LF-HG (11.3%), NF-HG (6.3%) and NF-LG patients (18.8%). At 5-year follow-up, global mortality remained persistently higher among LF-LG patients (64.5%) compared to LF-HG (47.9%), NF-HG (42.9%), and NF-LG patients (58.8%) (log-rank p: 0.029). At multivariable Cox hazard regression analysis, baseline SVi (HR: 0.951, 95% C.I.; 0.918-0.984), the presence of at least moderate tricuspid regurgitation at baseline (HR: 3.091, 95% C.I: 1.645-5.809) and at least moderate paravalvular leak (PVL) post-TAVI (HR: 1.456, 95% C.I.: 1.106-1.792) were significant independent predictors of late global mortality. LF-LG patients and LF-HG patients exhibited a significant increase in LVEF at 1-year follow-up. A lower LVEF (p < 0.001) and a lower Svi (p < 0.001) at baseline were associated with LVEF improvement at 1-year. Conclusions: Patients with LF-LG AS have acceptable 1-year outcomes with significant improvement in LVEF at 1-year follow-up, but exhibit exceedingly high 5-year mortality following TAVI. The presence of low transvalvular flow and at least moderate tricuspid regurgitation at baseline and significant paravalvular leak post-TAVI were associated with poorer long-term outcomes in the entire cohort of AS patients. The presence of a low LVEF or a low SVi predicts LVEF improvement at 1-year.

3.
JACC Case Rep ; 26: 102065, 2023 Nov 15.
Article in English | MEDLINE | ID: mdl-38094179

ABSTRACT

Suicide left ventricle after transcatheter aortic valve replacement is a well described phenomenon associated with increased morbidity and mortality. Prompt actions should be implemented to prevent this situation, and the alarm signs should be recognized. We present a case report of successful recognition, prevention and treatment of this complication. (Level of Difficulty: Intermediate.).

4.
Life (Basel) ; 13(6)2023 May 24.
Article in English | MEDLINE | ID: mdl-37374017

ABSTRACT

BACKGROUND: The presence of an electrocardiographic (ECG) strain pattern-among other ECG features-has been shown to be predictive of adverse cardiovascular outcomes in asymptomatic patients with aortic stenosis. However, data evaluating its impact on symptomatic patients undergoing TAVI are scarce. Therefore, we tried to investigate the prognostic impact of baseline ECG strain pattern on clinical outcomes after TAVI. METHODS: A sub-group of patients of the randomized DIRECT (Pre-dilatation in Transcatheter Aortic Valve Implantation Trial) trial with severe aortic stenosis who underwent TAVI with a self-expanding valve in one single center were consecutively enrolled. Patients were categorized into two groups according to the presence of ECG strain. Left ventricular strain was defined as the presence of ≥1 mm convex ST-segment depression with asymmetrical T-wave inversion in leads V5 to V6 on the baseline 12-lead ECG. Patients were excluded if they had paced rhythm or left bundle branch block at baseline. Multivariate Cox proportional hazard regression models were generated to assess the impact on outcomes. The primary clinical endpoint was all-cause mortality at 1 year after TAVI. RESULTS: Of the 119 patients screened, 5 patients were excluded due to left bundle branch block. Among the 114 included patients (mean age: 80.8 ± 7), 37 patients (32.5%) had strain pattern on pre-TAVI ECG, while 77 patients (67.5%) did not exhibit an ECG strain pattern. No differences in baseline characteristics were found between the two groups. At 1 year, seven patients reached the primary clinical endpoint, with patients in the strain group demonstrating significantly higher mortality in Kaplan-Meier plots compared to patients without left ventricular strain (five vs. two, log-rank p = 0.022). There was no difference between the strain and no strain group regarding the performance of pre-dilatation (21 vs. 33, chi-square p = 0.164). In the multivariate analysis, left ventricular strain was found to be an independent predictor of all-cause mortality after TAVI [Exp(B): 12.2, 95% Confidence Intervals (CI): 1.4-101.9]. CONCLUSION: Left ventricular ECG strain is an independent predictor of all-cause mortality after TAVI. Thus, baseline ECG characteristics may aid in risk-stratifying patients scheduled for TAVI.

5.
World J Cardiol ; 15(2): 45-55, 2023 Feb 26.
Article in English | MEDLINE | ID: mdl-36911750

ABSTRACT

Mechanical automated compression devices are being used in cardiopulmonary resuscitation instead of manual, "hands-on", rescuer-delivered chest compressions. The -theoretical- advantages include high-quality non-stop compressions, thus freeing the rescuer performing the compressions and additionally the ability of the rescuer to stand reasonably away from a potentially "hazardous" victim, or from hazardous and/or difficult resuscitation conditions. Such circumstances involve cardiopulmonary resuscitation (CPR) in the Cardiac Catheterization Laboratory, especially directly under the fluoroscopy panel, where radiation is well known to cause detrimental effects to the rescuer, and CPR during/after land or air transportation of cardiac arrest victims. Lastly, CPR in a coronavirus disease 2019 patient/ward, where the danger of contamination and further serious illness of the health provider is very existent. The scope of this review is to review and present literature and current guidelines regarding the use of mechanical compressions in these "hostile" and dangerous settings, while comparing them to manual compressions.

7.
J Cardiovasc Dev Dis ; 11(1)2023 Dec 22.
Article in English | MEDLINE | ID: mdl-38248874

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has been established as a safe and efficacious treatment for patients with severe symptomatic aortic stenosis (AS). Despite being initially developed and indicated for high-surgical-risk patients, it is now offered to low-risk populations based on the results of large randomized controlled trials. The most common access sites in the vast majority of patients undergoing TAVI are the common femoral arteries; however, 10-20% of the patients treated with TAVI require an alternative access route, mainly due to peripheral atherosclerotic disease or complex anatomy. Hence, to achieve successful delivery and implantation of the valve, several arterial approaches have been studied, including transcarotid (TCr), axillary/subclavian (A/Sc), transapical (TAp), transaortic (TAo), suprasternal-brachiocephalic (S-B), and transcaval (TCv). This review aims to concisely summarize the most recent literature data and current guidelines as well as evaluate the various access routes for TAVI, focusing on the indications, the various special patient groups, and the advantages and disadvantages of each technique, as well as their adverse events.

9.
J Card Surg ; 37(10): 3376-3377, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35949139

ABSTRACT

We describe a patient with symptomatic severe mitral regurgitation, due to a failed 33-mm Epic (St. Jude Medical, St. Paul, MN) bioprosthetic heart valve surgically implanted 10-year before. For this specific purpose, we implanted a novel balloon-expandable transcatheter heart valve, the MyVal (Meril Life Science, Vapi, India). To the best of our knowledge, this is the second case describing the implantation of MyVal in a degenerative, surgically placed bioprosthesis.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Mitral Valve/surgery , Prosthesis Design , Prosthesis Failure , Treatment Outcome
10.
Open Access Emerg Med ; 14: 63-75, 2022.
Article in English | MEDLINE | ID: mdl-35210874

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the level of established knowledge regarding cardiopulmonary resuscitation (CPR) during the pre-vaccine Covid-19 pandemic era of certified Basic Life Support (BLS) providers, as well as their attitude towards CPR and their willingness to provide CPR. METHODS: Certified BLS providers from courses held in Athens, Greece, were asked to complete an electronic survey regarding their knowledge of and stance towards performing CPR on victims with confirmed or suspected Covid-19 infection. Their insight on BLS courses was also assessed. Answers were collected during June 2020. RESULTS: Out of 5513 certified providers, 25.53% completed the survey. The majority (83.36%) would provide CPR to a cardiac arrest victim with possible or confirmed Covid-19 infection. Regarding the use of an automated external defibrillator, most respondents anticipated that it is equally safe as in the pre-Covid-19 period (58.24%). A more elementary level of education (p = 0.04) made rescuers more willing to provide CPR. Access to the European Resuscitation Council (ERC) or to the Greek National Public Health Organization (NPHO) guidelines was not correlated to the attitude towards resuscitation. Time since the last BLS seminar had no impact on the rescuers' attitude (p = 0.72). All responders agreed that training in CPR during Covid-19 remains necessary. CONCLUSION: Certified BLS providers maintained their willingness to perform CPR in cardiac arrest victims even during the pre-vaccine, dangerous Covid-19 pandemic period. Knowledge regarding Covid-19 CPR was satisfactory; however, continuous training, focused on the revised algorithms, was considered essential.

13.
Am J Cardiovasc Dis ; 11(3): 360-367, 2021.
Article in English | MEDLINE | ID: mdl-34322305

ABSTRACT

BACKGROUND: Carotid artery temperature heterogeneity (ΔΤ) measured by microwave radiometry (MWR) has been associated with future cardiovascular events including acute coronary syndromes. The vulnerable plaques of the coronary arterial tree, that can be ideally depicted by intracoronary imaging such as optical coherence tomography (OCT) have anatomical characteristics such as the thin fibrous cap (TCFA), that make them vulnerable to rupture. The scope of the study was to assess the implication of the carotid artery temperature heterogeneity on the culprit coronary plaque morphology in patients presenting with acute myocardial infarction. METHODS: 34 patients presented with an acute myocardial infarction were enrolled in the study. All patients underwent percutaneous coronary intervention (PCI) and OCT for the evaluation of the anatomical characteristics of the culprit lesion. After the completion of the PCI all patients underwent carotid ultrasound and MWR of both carotid arteries and thermal heterogeneity of the carotid arteries was assessed. Blood samples were collected for high sensitivity C-reactive protein (CRP) analysis. RESULTS: Thirty four patients, 21 with STEMI (61.76%) and 13 (38.23%) with NSTEMI, were included in the study. Patients with ruptured plaques had significantly increased hsCRP compared to patients that did not have a ruptured plaque (14.41±4.02 vs 9.9±2.5, P<0.005). Thermal heterogeneity, was significantly increased in ruptured plaques compared to no ruptured ones (1.01±0.31 vs 0.51±0.14°C, P=0.001), and in plaques with TCFA compared to those without a TCFA (0.82±0.37 vs 0.60±0.05°C, P=0.001). Diabetes mellitus, ΔΤ and hsCRP, were entered in the multivariate analysis, from which DM (OR 4.12; 95% CI 0.77-22.07; P=0.07) and ΔΤ (OR for 0.1°C increase 1.43; 95% CI 1.03-1.98; P=0.03) remained in the final analysis, and only ΔΤ was independently associated with the presence of the TCFA. Regarding plaque rupture, STEMI, hsCRP, and ΔT were entered in the multivariate analysis from which hsCRP (OR 1.51; 95% CI 0.99-2.28; P=0.051) and ΔΤ (OR for 0.1°C increase 3.40; 95% CI 1.29-8.96; P=0.013) remained in the final analysis with the ΔT being the only variable.

14.
Clin Microbiol Rev ; 34(4): e0001821, 2021 12 15.
Article in English | MEDLINE | ID: mdl-34319149

ABSTRACT

Cardiopulmonary resuscitation (CPR) is an emergency lifesaving endeavor, performed in either the hospital or outpatient settings, that significantly improves outcomes and survival rates when performed in a timely fashion. As with any other medical procedure, CPR can bear potential risks not only for the patient but also for the rescuer. Among those risks, transmission of an infectious agent has been one of the most compelling triggers of reluctance to perform CPR among providers. The concern for transmission of an infection from the resuscitated subject may impede prompt initiation and implementation of CPR, compromising survival rates and neurological outcomes of the patients. Infections during CPR can be potentially acquired through airborne, droplet, contact, or hematogenous transmission. However, only a few cases of infection transmission have been actually reported globally. In this review, we present the available epidemiological findings on transmission of different pathogens during CPR and data on reluctance of health care workers to perform CPR. We also outline the levels of personal protective equipment and other protective measures according to potential infectious hazards that providers are potentially exposed to during CPR and summarize current guidelines on protection of CPR providers from international societies and stakeholders.


Subject(s)
Cardiopulmonary Resuscitation , Humans
16.
Am J Cardiol ; 147: 80-87, 2021 05 15.
Article in English | MEDLINE | ID: mdl-33621524

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is an established method for treating patients with aortic valve stenosis. We sought to determine the long-term clinical outcomes and performance of a self-expanding bioprosthesis beyond 5 years. Consecutive patients scheduled for TAVI were included in the analysis. Primary end points were all-cause and cardiovascular mortality, structural valve deterioration (SVD) and bioprosthetic valve failure (BVF), based on the VARC-2 criteria and consensus statement by ESC/EAPCI. The study prospectively evaluated 273 patients (80.61 ± 7.00 years old, 47% females) who underwent TAVI with CoreValve/Evolut-R (Medtronic Inc.). The median follow-up duration was 5 years (interquartile range: 2.9 to 6; longest: 8 years). At 1, 5, and 8 years, estimated survival rates were 89.0%, 61.1%, and 56.0%, respectively, while cardiovascular mortality was 8% at the end of follow-up. Regarding valve performance, 5% of patients had early BVF and 1% had late BVF. Concerning SVD, 16 patients (6% of the total population) had moderate SVD (91% had an increase in mean gradient), with no severe SVD cases. Five patients with SVD died during follow-up. Actual analysis of the 8-year cumulative incidence of function of moderate SVD was 5.9% (2.5% to 16.2%). At multivariate analysis, the factor that emerged as an independent predictor for future SVD, was smaller bioprosthetic valve size (HR 0.58, 95% CI 0.41 to 0.82, p = 0.002). Long-term evaluation beyond 5 years after TAVI with a self-expanding bioprosthesis demonstrated low rates of cardiovascular mortality and structural valve deterioration. Valve size was an independent predictor for SVD.


Subject(s)
Aortic Valve Stenosis/surgery , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Cohort Studies , Female , Humans , Male , Prosthesis Failure , Risk Factors , Survival Rate , Time Factors , Treatment Outcome
18.
J Athl Train ; 56(10): 1137-1141, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-33351915

ABSTRACT

Despite the established benefits of regular physical activity in cardiovascular disease prevention, coronary events in the context of atherosclerotic coronary artery disease are the most common cause of exercise-related sudden death. A paradoxical development of an increased coronary calcification burden is likely associated with endurance training even in the absence of any of the traditional cardiovascular risk factors. In this case report, we present a 50-year-old male long-distance runner with excessive subclinical myocardial ischemia.


Subject(s)
Coronary Artery Disease , Running , Male , Humans , Middle Aged , Athletes , Exercise Test , Exercise
19.
Hellenic J Cardiol ; 62(1): 24-28, 2021.
Article in English | MEDLINE | ID: mdl-32949726

ABSTRACT

The unprecedented for modern medicine pandemic caused by the SARS-COV-2 virus ("coronavirus", Covid-19 disease) creates in turn new data on the management and survival of cardiac arrest victims, but mainly on the safety of CardioPulmonary Resuscitation (CPR) providers. The Covid-19 pandemic resulted in losses of thousands of lives, and many more people were hospitalized in simple or in intensive care unit beds, both globally and locally in Greece. More specifically, in victims of cardiac arrest, both in- and out- of hospital, the increased mortality and high contagiousness of the SARS-CoV-2 virus posed new questions, of both medical and moral nature/ to CPR providers. What we all know in resuscitation, that we cannot harm the victim and therefore do the most/best we can, is no longer the everyday reality. What we need to know and incorporate into decision-making in the resuscitation process is the distribution of limited human and material resources, the potentially very poor outcome of patients with Covid-19 and cardiac arrest, and especially that a potential infection of health professionals can lead in the lack of health professionals in the near future. This review tries to incorporate the added skills and precautions for CPR providers in terms of both in- and out- hospital CPR.


Subject(s)
COVID-19 , Cardiopulmonary Resuscitation , Heart Arrest , Occupational Health , COVID-19/mortality , COVID-19/prevention & control , COVID-19/transmission , Cardiopulmonary Resuscitation/ethics , Cardiopulmonary Resuscitation/methods , Cardiopulmonary Resuscitation/standards , Heart Arrest/therapy , Heart Arrest/virology , Humans , Occupational Exposure/prevention & control , Occupational Health/ethics , Occupational Health/standards , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...