Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 150
Filter
1.
Article in English | MEDLINE | ID: mdl-38837555

ABSTRACT

INTRODUCTION: Previous studies assessing the volume of radiological studies rarely considered the corresponding number of images. We aimed to quantify the increases in study and image numbers per radiologist in a tertiary healthcare network to better understand the demands on imaging services. METHODS: Using the Picture Archiving and Communication System (PACS), the number of images per study was obtained for all diagnostic studies reported by in-house radiologists at a tertiary healthcare network in Melbourne, Australia, between January 2009 and December 2022. Payroll data was used to obtain the numbers of full-time equivalent radiologists. RESULTS: Across all modalities, there were 4,462,702 diagnostic studies and 1,116,311,209 images. The number of monthly studies increased from 17,235 to 35,152 (104%) over the study period. The number of monthly images increased from 1,120,832 to 13,353,056 (1091%), with computed tomography (CT) showing the greatest absolute increase of 9,395,653 images per month (1476%). There was no increase in the monthly studies per full-time equivalent radiologist; however, the number of monthly image slices per radiologist increased 399%, from 48,781 to 243,518 (Kendall Tau correlation coefficient 0.830, P-value < 0.0001). CONCLUSION: The number of monthly images per radiologist increased substantially from 2009 to 2022, despite a relatively constant number of monthly studies per radiologist. Our study suggests that using the number of studies as an isolated fundamental data set underestimates the true radiologist's workload. We propose that the increased volume of images examined by individual radiologists may more appropriately reflect true work demand and may add more weight to future workforce planning.

2.
Emerg Radiol ; 31(1): 17-23, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38049601

ABSTRACT

PURPOSE: Primary epiploic appendagitis (PEA) is not an uncommon cause of abdominal pain. The systemic inflammatory response syndrome (SIRS) criteria have high sensitivity for early detection of inflammation and infection. To date, there is limited data about the association between SIRS and PEA. The aims of this retrospective study were to evaluate the prevalence of SIRS response and its clinical relevance in patients diagnosed with PEA within a large tertiary hospital network. METHODS: A retrospective study was performed on all consecutive adult patients who presented to four major emergency departments with CT-confirmed PEA from 01 January 2022 to 27 March 2023. The fulfilment of SIRS criteria, hospital admission rate and treatments provided were analysed for these patients. RESULTS: Seventy-three patients had CT-confirmed PEA. Seventeen patients (23.2%) with PEA were SIRS positive. The hospital admission rate in the SIRS group trended higher than the non-SIRS group (odds ratio of 2.51, 95% CI (0.75, 8.39)). The odds of having an associated radiological comorbidity unrelated to PEA were 18.7 times higher in the SIRS positive group. Fifty-seven (78%) patients were discharged home, and 16 (22%) patients were admitted into hospital. Nearly all patients were treated conservatively (98.6%). CONCLUSION: PEA patients with SIRS response trend towards a higher hospital admission rate and are significantly more likely to have other radiological comorbidities than non-SIRS patients. It is important to look for other pathological conditions in a SIRS positive patient with a CT-diagnosis of PEA.


Subject(s)
Systemic Inflammatory Response Syndrome , Tomography, X-Ray Computed , Adult , Humans , Prevalence , Retrospective Studies , Systemic Inflammatory Response Syndrome/diagnostic imaging , Systemic Inflammatory Response Syndrome/epidemiology , Diagnosis, Differential
3.
J Med Imaging Radiat Oncol ; 68(1): 87-93, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37694592

ABSTRACT

INTRODUCTION: Primary aldosteronism (PA) causes 10-15% of cases of hypertension, and it is increasingly recognised as being under-diagnosed. An interventional radiology procedure, adrenal vein sampling (AVS), is a necessary and important diagnostic procedure for complete workup of PA. There is an anticipated increase in demand for AVS as detection of PA improves. This study aims to describe the current landscape of AVS in Australia and New Zealand (NZ). METHODS: Two surveys exploring AVS methodology and performance were conducted of (i) Endocrinology Unit Heads and (ii) interventional radiologists who perform AVS, at public hospitals with Endocrinology Units across Australia and NZ. RESULTS: Responses were received from 48/53 Endocrinology Unit Heads (91%) and 35 radiologists from 26 sites (87% of AVS sites). AVS was provided at 28/48 Endocrinology sites (58%) across Australia and NZ. In Australia, sites were concentrated in Victoria, New South Wales and Queensland with none in the Northern Territory; in NZ, sites were more evenly distributed across the North and South Islands. AVS was performed by 1-2 dedicated radiologists at 24 sites, 2-3 radiologists at two sites and a rotating roster of radiologists at two sites. Responses to both surveys revealed significant variation in AVS methodology and interpretation of AVS results. CONCLUSION: There is significant heterogeneity in the availability of AVS, the procedural details and the interpretation of results across Australia and NZ, which potentially impacts the quality of patient care and ability to scale up AVS capacity to meet increasing demand.


Subject(s)
Adrenal Glands , Hyperaldosteronism , Humans , Hyperaldosteronism/diagnostic imaging , Hyperaldosteronism/etiology , New Zealand , New South Wales , Victoria , Retrospective Studies
5.
Emerg Radiol ; 30(4): 425-433, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37289287

ABSTRACT

INTRODUCTION: Computed tomography pulmonary angiography (CTPA) is the gold standard test to investigate pulmonary embolism (PE). This technique carries significant radiation risk in young females because of radiosensitive breast and thyroid tissues. A high-pitched CT technique offers significant radiation dose reduction (RDR) and minimises breathing artefact. The addition of CT tube tin-filtration may offer further RDR. The aim of this retrospective study was to assess RDR and image quality (IQ) of high-pitch tin-filtered (HPTF)-CTPA against conventional-CTPA. METHODS: Retrospective review of consecutive adult females age < 50 years undergoing high pitch tin filtration (HPTF) and standard pitch no tin filtration (SPNF) during a 3-year period beginning in November 2017. CTs in both groups were compared for radiation dose, pulmonary arteries contrast density (Hounsfield units (HU)) and movement artefact. Findings of both groups were compared with the Student's T-test and Mann-Whitney U test, where p < 0.05 being considered significant. Diagnostic quality was also recorded. RESULTS: Ten female patients (mean age 33, 6/10 pregnant) in HPTF group and 10 female patients (mean age 36, 1/10 pregnant) in SPNF group were included. The HPTF group achieved 93% RDR (dose length product: 25.15 mGy.cm vs 337.10 mGy.cm, p < 0.01). There was significant contrast density difference between the two groups in the main, left or right pulmonary arteries (322.72 HU, 311.85 HU and 319.41 HU in HPTF group vs 418.60 HU, 405.10 HU and 415.96 HU in SPNF group respectively, p = 0.03, p = 0.03 and p = 0.04). 8/10 HPTF group and 10/10 in the control group were > 250 HU in all three vessels; the remaining 2 HPTF CTPA were > 210HU. All CT scans in both groups were of diagnostic quality and none exhibited movement artefact. CONCLUSION: This study was the first to demonstrate significant RDR with the HPTF technique whilst maintaining IQ in patients undergoing chest CTPA. This technique is particularly beneficial in young females and pregnant females with suspected PE.


Subject(s)
Pulmonary Embolism , Tin , Adult , Humans , Female , Middle Aged , Retrospective Studies , Drug Tapering , Radiation Dosage , Pulmonary Embolism/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Tomography, X-Ray Computed/methods , Angiography/methods , Computed Tomography Angiography/methods
6.
J Med Imaging Radiat Oncol ; 67(6): 612-618, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37277645

ABSTRACT

INTRODUCTION: Cadaveric studies suggest an increasing prevalence of the persistent median artery (PMA) over a prolonged timeframe. The aim of this retrospective cross-sectional study was to evaluate the PMA prevalence in haemodialysis patients who had computed tomographic fistulograms (CTFs), and if present, their calibres and origins. METHODS: All consecutive adult patients referred for an upper limb CTFs for assessment of arteriovenous fistula (AVF) dysfunction from 2006 to 2021 were included. Patients whose CTF did not include the forearm were excluded. PMA was identified as an artery running alongside the median nerve between flexor digitorum superficialis and flexor digitorum profundus. Patient demographics, presence of PMA including size and origin were recorded. RESULTS: A PMA was found in 91/170 (53.5%) CTFs (7:3 male-to-female ratio, mean age 71-years). When stratified by age, prevalence increased with decreasing age; 51% in >70-year-olds, 54% in 50-70-year-olds and 67% in <50-year-olds. The average PMA diameter was 2.2 mm proximally and 1.8 mm distally. No stenosis was observed in the PMAs. CONCLUSION: The PMA prevalence appears to increase with decreasing age and is a frequently encountered anatomical variant. Radiologists assessing forearm vasculature need to be aware of this anatomical variant and potentially include it in their future reports. Further research into the PMA may make its potential use as arterial conduits for AVF, potential donor grafts for coronary artery bypass surgery or additional vascular access options possible. Whether the reducing prevalence with age reflects an overall increasing prevalence is yet to be determined.


Subject(s)
Angiography , Arteriovenous Fistula , Adult , Humans , Female , Male , Aged , Cross-Sectional Studies , Retrospective Studies , Radiography , Arteries , Arteriovenous Fistula/diagnostic imaging , Treatment Outcome
8.
PLoS One ; 18(1): e0279927, 2023.
Article in English | MEDLINE | ID: mdl-36652423

ABSTRACT

Changes to the voice are prevalent and occur early in Parkinson's disease. Correlates of these voice changes on four-dimensional laryngeal computed-tomography imaging, such as the inter-arytenoid distance, are promising biomarkers of the disease's presence and severity. However, manual measurement of the inter-arytenoid distance is a laborious process, limiting its feasibility in large-scale research and clinical settings. Automated methods of measurement provide a solution. Here, we present a machine-learning module which determines the inter-arytenoid distance in an automated manner. We obtained automated inter-arytenoid distance readings on imaging from participants with Parkinson's disease as well as healthy controls, and then validated these against manually derived estimates. On a modified Bland-Altman analysis, we found a mean bias of 1.52 mm (95% limits of agreement -1.7 to 4.7 mm) between the automated and manual techniques, which improves to a mean bias of 0.52 mm (95% limits of agreement -1.9 to 2.9 mm) when variability due to differences in slice selection between the automated and manual methods are removed. Our results demonstrate that estimates of the inter-arytenoid distance with our automated machine-learning module are accurate, and represents a promising tool to be utilized in future work studying the laryngeal changes in Parkinson's disease.


Subject(s)
Arytenoid Cartilage , Larynx , Parkinson Disease , Humans , Arytenoid Cartilage/diagnostic imaging , Larynx/diagnostic imaging , Parkinson Disease/diagnostic imaging , Tomography, X-Ray Computed
9.
NEJM Evid ; 2(1): EVIDoa2200183, 2023 Jan.
Article in English | MEDLINE | ID: mdl-38320086

ABSTRACT

BACKGROUND: Vocal cord dysfunction/inducible laryngeal obstruction (VCD/ILO) is characterized by breathlessness and often mimics or accompanies severe asthma. The disorder occurs intermittently, and the diagnosis is established by using laryngoscopy. Dynamic computed tomography (CT) imaging of the larynx at low-radiation doses has the potential to provide an alternative method to make the diagnosis of VCD/ILO. METHODS: We report two case series: in series A, laryngoscopy (diagnostic standard) and CT imaging of the larynx were each performed within 1 hour of each other (n=31), and in series B, the procedures were performed on separate days 4 to 6 weeks apart (n=72). Diagnosis of VCD/ILO by laryngoscopy used conventional criteria, and diagnosis by CT imaging was based on vocal cord narrowing in excess of a validated normal threshold. In each series, we evaluated the accuracy of CT imaging of the larynx to establish a diagnosis of VCD/ILO compared with laryngoscopy. RESULTS: In series A, the sensitivity of CT imaging of the larynx was 53.8%, and specificity was 88.9%; in series B, the sensitivity of CT imaging of the larynx was 76.2%, and specificity was 93.3%. At a disease prevalence of 30% (which was known to be the case in our clinic), the positive predictive value was 67.5% in series A and 83% in series B. Negative predictive values were 81.8% and 90.1% in series A and B, respectively, and false-positive rates were 11.1% and 6.7%. CONCLUSIONS: When the population prevalence was assumed to be 30%, low-dose CT imaging of the larynx detected VCD/ILO with negative predictive values greater than 80% in both series settings and agreed with each other within 9 percentage points. Positive predictive values for laryngeal CT imaging varied substantially between the settings of the two case series. (Supported by Monash Lung and Sleep Institute and Grant APP ID 1198362 and others.)


Subject(s)
Larynx , Vocal Cord Dysfunction , Humans , Vocal Cords , Vocal Cord Dysfunction/diagnosis , Laryngoscopy , Tomography, X-Ray Computed
10.
Macromolecules ; 56(24): 10111-10118, 2023 Dec 26.
Article in English | MEDLINE | ID: mdl-38161326

ABSTRACT

An experimental study and kinetic model analysis of the initiated chemical vapor deposition (iCVD) of polymer thin films have been performed at saturated monomer vapor conditions. Previous iCVD kinetic studies have focused on subsaturated monomer conditions where polymer deposition kinetics is known to be limited by monomer adsorption. However, iCVD kinetics at saturated conditions have so far not been systematically investigated, and it remains unclear whether the adsorption-limited phenomenon would still apply at saturation, given the abundance of monomer for reaction. To probe this question, a series of depositions of poly(vinylpyrrolidone) (PVP) thin films as a model system were performed by iCVD at substrate temperatures from 10 to 25 °C at both fully saturated (100%) and subsaturated (50%) conditions. While the deposition rates at subsaturated conditions exhibit the expected adsorption-limited behavior, the deposition rates at saturated conditions unexpectedly show two distinct deposition regimes with reaction time: an initial adsorption-limited regime followed by a kinetically limited steady-state regime. In the steady-state regime, the deposition kinetics is found to be thermally activated by raising substrate temperature with an overall activation energy of +86 kJ/mol, which agrees reasonably well with the experimentally determined value of +89 kJ/mol in the literature for bulk PVP polymerization and a mechanistically derived value of +91 kJ/mol based on the bulk free radical polymerization mechanism of PVP. These findings open new operating windows for iCVD polymerization and thin-film growth in which fast polymer deposition can be achieved without substrate cooling that can greatly simplify the iCVD scale-up to roll-to-roll processing and enable iCVD polymerization of highly volatile monomers relevant for diverse applications in biomedicine, smart wearables, and renewable energy.

12.
J Med Imaging Radiat Oncol ; 66(8): 1089-1096, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36125112

ABSTRACT

Granulomatosis with polyangiitis (GPA) is a multisystemic autoimmune small vessel vasculitis predominantly affecting the respiratory and renal systems. Other systems such as the central nervous system, orbital, cardiac and gastrointestinal systems may also be involved to a lesser degree. Although there are no imaging features that are pathognomonic for GPA, there are known radiological patterns suggestive of the disease and imaging plays an important role in diagnosis, assessment and monitoring of disease activity. This is more evident when combined with clinical features, biochemical values and histopathology results. This pictorial review aims to present both common and uncommon radiological features of GPA.


Subject(s)
Granulomatosis with Polyangiitis , Humans , Granulomatosis with Polyangiitis/diagnostic imaging , Diagnostic Imaging , Respiratory System
13.
Respirology ; 27(8): 581-599, 2022 08.
Article in English | MEDLINE | ID: mdl-35758539

ABSTRACT

Interventional radiology (IR) is a rapidly expanding medical subspecialty and refers to a range of image-guided procedural techniques. The image guidance allows real-time visualization and precision placement of a needle, catheter, wire and device to deep body structures through small incisions. Advantages include reduced risks, faster recovery and shorter hospital stays, lower costs and less patient discomfort. The range of chest interventional procedures keeps on expanding due to improved imaging facilities, better percutaneous assess devices and advancing ablation and embolization techniques. These advances permit procedures to be undertaken safely, simultaneously and effectively, hence escalating the role of IR in the treatment of chest disorders. This review article aims to cover the latest developments in some image-guided techniques of the chest, including thermal ablation therapy of lung malignancy, targeted therapy of pulmonary embolism, angioplasty and stenting of mediastinal venous/superior vena cava occlusion, pulmonary arteriovenous malformation treatment and bronchial artery embolization for haemoptysis.


Subject(s)
Arteriovenous Fistula , Embolization, Therapeutic , Humans , Pulmonary Artery , Stents , Vena Cava, Superior
14.
Emerg Radiol ; 29(5): 809-817, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35612644

ABSTRACT

PURPOSE: Portable chest radiographs (CXRs) continue to be a vital diagnostic tool for emergency and critical care medicine. The scatter correction algorithm (SCA) is a post-processing algorithm aiming to reduce scatter within portable images. This study aimed to assess whether the SCA improved image quality (IQ) in portable CXRs. METHODS: Objective and subjective IQ assessments were undertaken on both phantom and clinical images, respectively. For objective analysis, attenuators were placed on the anterior surface of the patient's thorax to simulate pathologies present within uniform regions of the phantom's lung and heart. Phantom CXRs were acquired with three different tube-current-times (mAs). Phantom images were processed with different SCA strengths. Contrast to noise ratios (CNR) within the attenuator were determined for each algorithm strength and compared to non-SCA images. For subjective analysis, two independent radiologists graded 30 clinical images with and without the SCA activated. The images were graded for IQ in different anatomical structures and overall diagnostic confidence. RESULTS: Objectively, most strengths of the SCA improved the CNR in both regions. However, a detrimental effect was recorded for some algorithm strengths in regions of high contrast. Subjectively, both observers recorded the SCA significantly improved IQ in clinical CXRs in all anatomical regions. Observers indicated the greatest improvement in the lung and hilar regions, and least improvement in the chest wall and bone. All images with and without the SCA were deemed diagnostic. CONCLUSION: This study shows the potential radiation dose neutral IQ improvement when using an SCA in clinical patient CXRs.


Subject(s)
Algorithms , Thorax , Humans , Phantoms, Imaging , Radiography , Radiography, Thoracic/methods
17.
BMJ Case Rep ; 15(2)2022 Feb 10.
Article in English | MEDLINE | ID: mdl-35144961

ABSTRACT

A 62-year-old man presented with acute abdominal and flank pain, oligoanuria and severe acute kidney injury. Unenhanced CT imaging did not detect urolithiasis or hydronephrosis. There was an early blood pressure surge followed by an intense inflammatory response, with a rise in peripheral blood leucocytes and C reactive protein. His urinalysis was bland but the serum lactate dehydrogenase was markedly elevated. CT angiograms demonstrated multiple pulmonary emboli and bilateral renal artery thromboembolism, with occlusion of the left main renal artery. Despite an 88-hour delay from pain onset, catheter-directed thrombolysis and thromboaspiration of both renal arteries were successfully performed, allowing the patient to recover enough kidney function to cease haemodialysis. A patent foramen ovale with right-to-left shunting was discovered, and paradoxical embolism was suspected as the cause of renal infarction. The benefit of catheter-directed reperfusion after prolonged bilateral renal ischaemia is not easily predicted by the severity or duration of acute kidney injury alone.


Subject(s)
Acute Kidney Injury , Embolism, Paradoxical , Foramen Ovale, Patent , Pulmonary Embolism , Thromboembolism , Acute Kidney Injury/etiology , Acute Kidney Injury/therapy , Catheters , Humans , Kidney/diagnostic imaging , Male , Middle Aged
18.
Respirology ; 27(1): 56-65, 2022 01.
Article in English | MEDLINE | ID: mdl-34693587

ABSTRACT

BACKGROUND AND OBJECTIVE: Right ventricular (RV) volumes are crucial outcome determinants in pulmonary diseases. Little is known about the associations of RV volumes during hospitalized acute exacerbations of chronic obstructive pulmonary disease (AECOPD). We aimed to ascertain associations of RV end-diastolic volume indexed to body surface area (RVEDVI) during hospitalized AECOPD and its relationship with mortality in long-term follow-up. METHODS: This is a prospective observational cohort study (December 2013-November 2019, ACTRN12617001562369) using dynamic retrospective ECG-gated computed tomography during hospitalized AECOPD. RVEDVI was defined as normal or high using Framingham Offspring Cohort values. Cox regression determined the prognostic relevance of RVEDVI for death. RESULTS: A total of 148 participants (70 ± 10 years [mean ± SD], 88 [59%] men) were included, of whom 75 (51%) had high RVEDVI. This was associated with more frequent hospital admissions in the 12 months before admission (52/75 [69%] vs. 38/73 [52%], p = 0.04) and higher breathlessness (modified Medical Research Council score, 2.9 ± 1.3 vs. 2.4 ± 1.2, p = 0.007). During follow-up, high RVEDVI was associated with greater mortality (log-rank p = 0.001). In univariable Cox regression, increasing RVEDVI was associated with higher mortality (hazard ratio [HR]: 1.02 per ml/m2 ; 95% CI: 1.01, 1.03; p = 0.001). In multivariable Cox regression, RVEDVI was independently associated with mortality (HR: 1.01 per ml/m2 ; 95% CI: 1.00, 1.03; p = 0.050) at a borderline significance level. Adding RVEDVI to three COPD mortality prediction systems improved model fit (pooled chi-square test [BODE: p = 0.05, ADO: p = 0.04, DOSE: p = 0.02]). CONCLUSION: In patients with hospitalized AECOPD, higher RV end-diastolic volume was associated with worse acute clinical parameters and greater mortality.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Tetralogy of Fallot , Humans , Male , Prospective Studies , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Retrospective Studies , Stroke Volume
19.
J Med Imaging Radiat Oncol ; 66(3): 351-356, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34415110

ABSTRACT

INTRODUCTION: Venous air embolization (VAE) from IV lines is a risk with IV contrast administration. The incidence of VAE ranges from 7% to 23%. While life-threatening VAE is rare, there is the potential risk of serious cerebrovascular events from paradoxical systemic air embolization (SAE) in patients with congenital intracardiac shunts. CT coronary angiogram (CTCA) hypothetically carries a higher risk of VAE as it requires dual injections as compared to single bolus dose contrast used in CT chest (CTC). The aim of this study was to assess the risk of VAE using CTCA as compared to conventional CTC. The incidence of cardiac shunts and their association with paradoxical SAE were also investigated. METHODS: A retrospective study was conducted at a tertiary hospital. Adult patients undergoing CTCA and CTC over a 6-month period in 2017 were included. Images were reviewed on PACS for the presence of VAE. Electronic medical records were interrogated for evidence of neurological sequelae or requiring neurological imaging (CTB/MRIB) within 1 month of the initial imaging. RESULTS: 508 patients were included, 408 underwent CTCA and 100 underwent CTC. The VAE incidence in CTCA was 24% (94 patients) and 10% in the CTC (10 patients). This was statistically significant. Among the CTCA group, 36% (108 patients) had an intracardiac shunt. No statistically significant difference in VAE incidence was identified in CTCA patients with shunts vs without shunts. There was no incidence of SAE in both groups. CONCLUSION: VAE is more common with CTCA than conventional CTC. There were no cases of paradoxical SAE found.


Subject(s)
Embolism, Air , Adult , Computed Tomography Angiography , Coronary Angiography , Embolism, Air/diagnostic imaging , Embolism, Air/epidemiology , Embolism, Air/etiology , Humans , Incidence , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...