Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Esp Enferm Dig ; 109(11): 741-742, 2017 11.
Article in English | MEDLINE | ID: mdl-29082741

ABSTRACT

One of the challenges in coeliac disease is the significant under-diagnosis despite the increasing prevalence and international guidelines for serological screening in appropriate patient cohorts. Several point-of-care tests for coeliac disease have been developed over the past decade with the aim of improving case detection using rapid and convenient testing. Most point-of-care tests, such as Biocard, detect anti-tissue transglutaminase (tTG) IgA antibodies, whereas Simtomax uniquely detects anti-deamidated gliadin peptide (DGP) IgA/IgG antibodies. A recent head-to-head trial in adults comparing two tTG-based point-of-care tests (Biocard and Celiac Quick Test) and Simtomax found that Simtomax was superior to Biocard and Celiac Quick Test, with sensitivities of 92.7%, 72.2% and 77.8%, respectively.


Subject(s)
Celiac Disease , Adult , Child , Gliadin , Humans , Immunoglobulin A , Immunoglobulin G , Peptides , Point-of-Care Systems , Point-of-Care Testing
2.
Curr Opin Gastroenterol ; 33(3): 173-180, 2017 May.
Article in English | MEDLINE | ID: mdl-28177956

ABSTRACT

PURPOSE OF REVIEW: The diagnostic approach in celiac disease is continuously evolving as our understanding of its pathophysiology improves. This review aims to provide a summary of contemporary work that supports optimization of the diagnosis of this common yet underdiagnosed condition. RECENT FINDINGS: The recently updated National Institute of Clinical Excellence and European Society for Pediatric Gastroenterology, Hepatology, and Nutrition guidelines and the contentious biopsy-free diagnostic approach will be discussed. We will review the evidence advocating optimal biopsy techniques such as single bite biopsy and controversial bulb biopsy sampling to increase diagnostic yield. Recent data providing phenotypical characterization and clinical outcomes of celiac subtypes such as potential celiac disease, seronegative celiac disease and ultrashort celiac disease will be covered. We will present emerging evidence on novel case finding strategies with point of care tests. Promising novel markers for celiac disease such as serum intestinal fatty acid binding protein and in-vitro gluten challenge will be included. SUMMARY: Recent work has demonstrated the clinical significance of the celiac disease subtypes, emphasizing the importance of careful diagnosis and recognition. There is a move toward a less invasive and perhaps more cost-effective diagnostic approach in celiac disease, but duodenal biopsy remains the gold standard at present for all adults and the majority of pediatric patients.


Subject(s)
Celiac Disease/diagnosis , Biomarkers/blood , Biopsy , Celiac Disease/diet therapy , Celiac Disease/pathology , Diet, Gluten-Free , Duodenoscopy , Duodenum/pathology , Histocompatibility Testing , Humans , Mass Screening/methods , Point-of-Care Testing , Practice Guidelines as Topic
4.
BMC Gastroenterol ; 16: 115, 2016 Sep 15.
Article in English | MEDLINE | ID: mdl-27628523

ABSTRACT

BACKGROUND: International guidelines recommend coeliac serology in iron deficiency anaemia, and duodenal biopsy for those tested positive to detect coeliac disease. However, pre-endoscopy serology is often unavailable, thus committing endoscopists to take routine duodenal biopsies. Some endoscopists consider duodenal biopsy mandatory in anaemia to exclude other pathologies. We hypothesise that using a point of care test at endoscopy could fill this gap, by providing rapid results to target anaemic patients who require biopsies, and save costs by biopsy avoidance. We therefore assessed three key aspects to this hypothesis: 1) the availability of pre-endoscopy serology in anaemia; 2) the sensitivities and cost effectiveness of pre-endoscopy coeliac screening with Simtomax in anaemia; 3) whether other anaemia-related pathologies could be missed by this targeted-biopsy approach. METHODS: Group 1: pre-endoscopy serology availability was retrospectively analysed in a multicentre cohort of 934 anaemic patients at 4 UK hospitals. Group 2: the sensitivities of Simtomax, endomysial and tissue-transglutaminase antibodies were compared in 133 prospectively recruited patients with iron deficiency anaemia attending for a gastroscopy. The sensitivities were measured against duodenal histology as the reference standard in all patients. The cost effectiveness of Simtomax was calculated based on the number of biopsies that could have been avoided compared to an all-biopsy approach. Group 3: the duodenal histology of 153 patients presenting to a separate iron deficiency anaemia clinic were retrospectively reviewed. RESULTS: In group 1, serology was available in 361 (33.8 %) patients. In group 2, the sensitivity and negative predictive value (NPV) were 100 % and 100 % for Simtomax, 96.2 % and 98.9 % for IgA-TTG, and 84.6 % and 96.4 % for EMA respectively. In group 3, the duodenal histology found no causes for anaemia other than coeliac disease. CONCLUSION: Simtomax had excellent diagnostic accuracy in iron deficiency anaemia and was comparable to conventional serology. Duodenal biopsy did not identify any causes other than coeliac disease for iron deficiency anaemia, suggesting that biopsy avoidance in Simtomax negative anaemic patients is unlikely to miss other anaemia-related pathologies. Due to its 100 % NPV, Simtomax could reduce unnecessary biopsies by 66 % if only those with a positive Simtomax were biopsied, potentially saving £3690/100 gastroscopies. TRIAL REGISTRATION: The group 2 study was retrospectively registered with clinicaltrials.gov. Trial registration date: 13(th) July 2016; TRIAL REGISTRATION NUMBER: NCT02834429 .


Subject(s)
Anemia, Iron-Deficiency/blood , Celiac Disease/diagnosis , Point-of-Care Testing/economics , Point-of-Care Testing/statistics & numerical data , Preoperative Care/methods , Adolescent , Adult , Aged , Aged, 80 and over , Anemia, Iron-Deficiency/etiology , Anemia, Iron-Deficiency/surgery , Biopsy , Celiac Disease/complications , Celiac Disease/surgery , Cost Savings , Duodenum/pathology , Female , Gastroscopy , Gliadin/blood , Humans , Immunoglobulin A/blood , Immunoglobulin G/blood , Male , Middle Aged , Models, Economic , Peptides/blood , Predictive Value of Tests , Preoperative Care/economics , Prospective Studies , Retrospective Studies , Sensitivity and Specificity , Serologic Tests/economics , Serologic Tests/methods , Serologic Tests/statistics & numerical data , United Kingdom , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...