Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
J Magn Reson Imaging ; 50(1): 193-200, 2019 07.
Article in English | MEDLINE | ID: mdl-30390363

ABSTRACT

BACKGROUND: Few studies directed at assessing the visualization of the walls of unruptured aneurysms have used higher-resolution 3D MRI vessel wall imaging. Prospective longitudinal studies are also needed to screen vessel wall changes in unruptured aneurysms. PURPOSE: To compare the aneurysm wall visualization on pre- and post-3D isotropic T1 -weighted Sampling Perfection with Application-optimized Contrasts by using different flip angle Evolutions (SPACE) images and to explore whether there is a change in wall enhancement at follow up. STUDY TYPE: Prospective. POPULATION: Twenty-nine patients with a total of 35 unruptured intracranial aneurysms. SEQUENCE: 3D T1 -weighted pre- and postcontrast SPACE (0.5 mm isotropic) at 3.0T. ASSESSMENT: The aneurysm wall visibility (0-5 scale) between pre- and postcontrast images as well as the wall enhancement (0-5 scale) between follow-up and baseline studies (6-30 months, average 12.7 months) were compared. Differences in wall visibility and enhancement were also investigated as a function of aneurysm diameter and location. STATISTICAL TEST: The Wilcoxon signed rank paired test was used to compare the wall visibility score between pre- and postcontrast SPACE images, as well as wall enhancement between follow-up and baseline. The Mann-Whitney and Kruskal-Wallis tests were used to investigate the enhancement difference between different diameters and locations. RESULTS: Postcontrast images had significantly higher wall visibility (P = 0.01). A wall enhancement score ≥2 was found in 71% of the aneurysms. Changes in levels of wall enhancement were found in 17% of the aneurysms at follow-up studies, but those changes were small. Wall visibility and enhancement scores of large aneurysms were significantly higher than small ones (P < 0.001). DATA CONCLUSION: 3D T1 -weighted higher resolution SPACE can be used to assess changes in enhancement at follow-up studies. Contrast SPACE image provides better aneurysm wall visibility and improves visualization of the aneurysm wall. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019;50:193-200.


Subject(s)
Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Intracranial Aneurysm/diagnostic imaging , Adult , Aged , Brain/diagnostic imaging , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Prospective Studies
2.
MAGMA ; 31(2): 295-307, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28785850

ABSTRACT

OBJECTIVES: To evaluate an accelerated 4D flow MRI method that provides high temporal resolution in a clinically feasible acquisition time for intracranial velocity imaging. MATERIALS AND METHODS: Accelerated 4D flow MRI was developed by using a pseudo-random variable-density Cartesian undersampling strategy (CIRCUS) with the combination of k-t, parallel imaging and compressed sensing image reconstruction techniques (k-t SPARSE-SENSE). Four-dimensional flow data were acquired on five healthy volunteers and eight patients with intracranial aneurysms using CIRCUS (acceleration factor of R = 4, termed CIRCUS4) and GRAPPA (R = 2, termed GRAPPA2) as the reference method. Images with three times higher temporal resolution (R = 12, CIRCUS12) were also reconstructed from the same acquisition as CIRCUS4. Qualitative and quantitative image assessment was performed on the images acquired with different methods, and complex flow patterns in the aneurysms were identified and compared. RESULTS: Four-dimensional flow MRI with CIRCUS was achieved in 5 min and allowed further improved temporal resolution of <30 ms. Volunteer studies showed similar qualitative and quantitative evaluation obtained with the proposed approach compared to the reference (overall image scores: GRAPPA2 3.2 ± 0.6; CIRCUS4 3.1 ± 0.7; CIRCUS12 3.3 ± 0.4; difference of the peak velocities: -3.83 ± 7.72 cm/s between CIRCUS4 and GRAPPA2, -1.72 ± 8.41 cm/s between CIRCUS12 and GRAPPA2). In patients with intracranial aneurysms, the higher temporal resolution improved capturing of the flow features in intracranial aneurysms (pathline visualization scores: GRAPPA2 2.2 ± 0.2; CIRCUS4 2.5 ± 0.5; CIRCUS12 2.7 ± 0.6). CONCLUSION: The proposed rapid 4D flow MRI with a high temporal resolution is a promising tool for evaluating intracranial aneurysms in a clinically feasible acquisition time.


Subject(s)
Imaging, Three-Dimensional , Intracranial Aneurysm/diagnostic imaging , Magnetic Resonance Imaging , Adult , Blood Flow Velocity , Female , Healthy Volunteers , Humans , Image Enhancement , Image Processing, Computer-Assisted , Magnetic Resonance Angiography , Male , Reproducibility of Results
3.
MAGMA ; 31(3): 457-467, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29209856

ABSTRACT

OBJECTIVE: Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging. MATERIALS AND METHODS: A 3D accelerated T1-weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded. RESULTS: The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR. CONCLUSION: In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T1-weighted SPACE while maintaining good image quality.


Subject(s)
Aneurysm/diagnostic imaging , Atherosclerosis/diagnostic imaging , Brain/blood supply , Brain/diagnostic imaging , Cerebrovascular Circulation , Contrast Media/chemistry , Magnetic Resonance Imaging , Adult , Aged , Algorithms , Cerebrovascular Disorders/diagnostic imaging , Female , Healthy Volunteers , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Male , Middle Aged , Models, Statistical , Poisson Distribution , Reproducibility of Results , Signal-To-Noise Ratio
4.
Magn Reson Med ; 79(4): 1962-1971, 2018 04.
Article in English | MEDLINE | ID: mdl-28745409

ABSTRACT

PURPOSE: To measure the Reynolds stress tensor using 4D flow MRI, and to evaluate its contribution to computed pressure maps. METHODS: A method to assess both velocity and Reynolds stress using 4D flow MRI is presented and evaluated. The Reynolds stress is compared by cross-sectional integrals of the Reynolds stress invariants. Pressure maps are computed using the pressure Poisson equation-both including and neglecting the Reynolds stress. RESULT: Good agreement is seen for Reynolds stress between computational fluid dynamics, simulated MRI, and MRI experiment. The Reynolds stress can significantly influence the computed pressure loss for simulated (eg, -0.52% vs -15.34% error; P < 0.001) and experimental (eg, 306 ± 11 vs 203 ± 6 Pa; P < 0.001) data. A 54% greater pressure loss is seen at the highest experimental flow rate when accounting for Reynolds stress (P < 0.001). CONCLUSION: 4D flow MRI with extended motion-encoding enables quantification of both the velocity and the Reynolds stress tensor. The additional information provided by this method improves the assessment of pressure gradients across a stenosis in the presence of turbulence. Unlike conventional methods, which are only valid if the flow is laminar, the proposed method is valid for both laminar and disturbed flow, a common presentation in diseased vessels. Magn Reson Med 79:1962-1971, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Subject(s)
Magnetic Resonance Imaging/methods , Algorithms , Blood Flow Velocity , Computer Simulation , Constriction, Pathologic/physiopathology , Humans , Hydrodynamics , Imaging, Three-Dimensional , Models, Cardiovascular , Motion , Phantoms, Imaging , Poisson Distribution , Pressure , Reproducibility of Results , Stress, Mechanical
5.
MAGMA ; 29(3): 559-70, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26946509

ABSTRACT

OBJECTIVES: High resolution MRI of the intracranial vessel wall provides important insights in the assessment of intracranial vascular disease. This study aims to refine high resolution 3D MRI techniques for intracranial vessel wall imaging at both 3 and 7 T using customized flip angle train design, and to explore their comparative abilities. MATERIALS AND METHODS: 11 patients with intracranial artery disease (four atherosclerotic plaques, six aneurysms and one reversible cerebral vasoconstriction syndrome) were imaged at 3 and 7 T with a 3D T 1-weighted fast-spin-echo sequence (SPACE) both pre and post Gd contrast injection. Wall to lumen contrast ratio (CRwall-lumen), contrast enhancement ratio (ER) and the sharpness of the vessel wall were quantified. Two experienced radiologists evaluated the image quality on a 0-5 scale. RESULTS: Both 3 and 7 T achieved good image quality with high resolution (nominal 0.5 mm isotropic) and whole brain coverage. The CRwall-lumen and the ER measurements were comparable (p > 0.05). The 7 T images were significantly sharper (sharpness: 2.69 ± 0.50 vs. 1.88 ± 0.53 mm(-1), p < 0.001) with higher image quality (reader 1 score: 3.5 ± 1.1 vs. 2.4 ± 1.1, p = 0.002) compared to 3 T. CONCLUSIONS: 3D T 1-weighted SPACE can be used for intracranial vessel wall evaluation at both 3 and 7 T. 7 T provides significantly better image quality and improves the confidence of diagnosis.


Subject(s)
Aneurysm/diagnostic imaging , Atherosclerosis/diagnostic imaging , Magnetic Resonance Imaging/methods , Adult , Aged , Aneurysm/physiopathology , Atherosclerosis/physiopathology , Brain/blood supply , Computer Simulation , Contrast Media/chemistry , Female , Gadolinium/chemistry , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Radiology/methods , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio
6.
Magn Reson Imaging ; 34(1): 18-25, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26471514

ABSTRACT

INTRODUCTION: The aortic wall and intraluminal thrombus (ILT) have been increasingly studied as potential markers of progressive disease with abdominal aortic aneurysms (AAAs). Our goal was to develop a high resolution, 3D black blood MR technique for AAA wall and ILT imaging within a clinically acceptable scan time. METHODS: Twenty two patients with AAAs (maximal diameter 4.3±1.0cm), along with five healthy volunteers, were imaged at 3T with a 3D T1-weighted fast-spin-echo sequence using variable flip angle trains (SPACE) with a preparation pulse (DANTE) for suppressing blood signal. Volunteers and ten patients were also scanned with SPACE alone for comparison purposes. The signal to noise ratio (SNR) and the aortic wall/ILT to lumen contrast to noise ratio (CNR) were measured. Qualitative image scores (1-4 scale) assessing the inner lumen and outer wall boundaries of AAA were performed by two blinded reviewers. In patients with ILT, the ratio of ILT signal intensity (ILTSI) over psoas muscle SI (MuscleSI) was calculated, and the signal heterogeneity of ILT was quantified as standard deviation (SD) over the mean. RESULTS: All subjects were imaged successfully with an average scan time of 7.8±0.7minutes. The DANTE preparation pulse for blood suppression substantially reduced flow artifacts in SPACE with lower lumen SNR (8.8 vs. 21.4, p<0.001) and improved the wall/ILT to lumen CNR (9.9 vs. 6.3, p<0.001) in patients. Qualitative assessment showed improved visualization of lumen boundaries (73% higher scores on average, p=0.01) and comparable visualization of outer wall boundary (p>0.05). ILT was present in ten patients, with relatively high signal and a wide SD (average ILTSI/MuscleSI 1.42±0.48 (range 0.75-2.11)) and with SD/mean of 27.7%±6.6% (range 19.6%-39.4%). CONCLUSION: High resolution, 3D black blood MRI of AAAs can be achieved in a clinical accepted scan time with reduction of flow artifacts using the DANTE preparation pulse. Signal characteristics of ILT can be quantified and may be used for improved patient-specific risk stratification.


Subject(s)
Aortic Aneurysm, Abdominal/pathology , Aortic Valve Stenosis/pathology , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/methods , Thrombosis/pathology , Aged , Algorithms , Anisotropy , Aortic Aneurysm, Abdominal/complications , Aortic Valve Stenosis/complications , Humans , Image Enhancement/methods , Male , Reproducibility of Results , Sensitivity and Specificity , Thrombosis/complications
7.
Magn Reson Med ; 74(2): 474-81, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25157749

ABSTRACT

PURPOSE: To study temporal and spatial blurring artifacts from k-space view-sharing in time-resolved MR angiography (MRA) and to propose a technique for reducing these artifacts. METHODS: We acquired k-space data sets using a three-dimensional time-resolved MRA view-sharing sequence and retrospectively reformatted them into two reconstruction frameworks: full view-sharing via time-resolved imaging with stochastic trajectories (TWIST) and minimal k-space view-sharing and compressed sensing (CS-TWIST). The two imaging series differed in temporal footprint but not in temporal frame rate. The artifacts from view-sharing were compared qualitatively and quantitatively in nine patients in addition to a phantom experiment. RESULTS: CS-TWIST was able to reduce the imaging temporal footprint by two- to three-fold compared with TWIST, and the overall subjective image quality of CS-TWIST was higher than that for TWIST (P < 0.05). View sharing caused a delay in the visualization of small blood vessels, and the mean transit time of the carotid artery calculated based on TWIST reconstruction was 0.6 s longer than that for CS-TWIST (P < 0.01). In thoracic MRA, the shorter temporal footprint decreased the sensitivity to physiological motion blurring, and vessel sharpness was improved by 8.8% ± 6.0% using CS-TWIST (P < 0.05). CONCLUSION: In time-resolved MRA, the longer temporal footprint due to view-sharing causes spatial and temporal artifacts. CS-TWIST is a promising method for reducing these artifacts.


Subject(s)
Algorithms , Artifacts , Data Compression/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/instrumentation , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Spatio-Temporal Analysis
8.
J Magn Reson Imaging ; 42(3): 698-708, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25483607

ABSTRACT

PURPOSE: To present and assess a procedure for measurement of spinal cord total cross-sectional areas (TCA) and gray matter (GM) areas based on phase-sensitive inversion recovery imaging (PSIR). In vivo assessment of spinal cord GM and white matter (WM) could become pivotal to study various neurological diseases, but it is challenging because of insufficient GM/WM contrast provided by conventional magnetic resonance imaging (MRI). MATERIALS AND METHODS: We acquired 2D PSIR images at 3T at each disc level of the spinal axis in 10 healthy subjects and measured TCA, cord diameters, WM and GM areas, and GM area/TCA ratios. Second, we investigated 32 healthy subjects at four selected levels (C2-C3, C3-C4, T8-T9, T9-T10, total acquisition time <8 min) and generated normative reference values of TCA and GM areas. We assessed test-retest, intra- and interoperator reliability of the acquisition strategy, and measurement steps. RESULTS: The measurement procedure based on 2D PSIR imaging allowed TCA and GM area assessments along the entire spinal cord axis. The tests we performed revealed high test-retest/intraoperator reliability (mean coefficient of variation [COV] at C2-C3: TCA = 0.41%, GM area = 2.75%) and interoperator reliability of the measurements (mean COV on the 4 levels: TCA = 0.44%, GM area = 4.20%; mean intraclass correlation coefficient: TCA = 0.998, GM area = 0.906). CONCLUSION: 2D PSIR allows reliable in vivo assessment of spinal cord TCA, GM, and WM areas in clinically feasible acquisition times. The area measurements presented here are in agreement with previous MRI and postmortem studies.


Subject(s)
Gray Matter/pathology , Magnetic Resonance Imaging , Spinal Cord/pathology , White Matter/pathology , Adult , Aged , Cohort Studies , Cross-Sectional Studies , Female , Healthy Volunteers , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Nervous System Diseases/physiopathology , Reference Values , Reproducibility of Results , Signal-To-Noise Ratio , Time Factors , Whole Body Imaging
9.
Magn Reson Med ; 73(1): 312-7, 2015 Jan.
Article in English | MEDLINE | ID: mdl-24478221

ABSTRACT

PURPOSE: To develop a respiratory self-gating method, adaptive online self-gating (ADIOS), for noncontrast MR angiography (NC MRA) of renal arteries to overcome some limitations of current free-breathing methods. METHODS: A NC MRA pulse sequence for online respiratory self-gating was developed based on three-dimensional balanced steady-state free precession (bSSFP) and slab-selective inversion-recovery. Motion information was derived directly from the slab being imaged for online gating. Scan efficiency was maintained by an automatic adaptive online algorithm. Qualitative and quantitative assessments of image quality were performed and results were compared with conventional diaphragm navigator (NAV). RESULTS: NC MRA imaging was successfully completed in all subjects (n = 15). Similarly good image quality was observed in the proximal-middle renal arteries with ADIOS compared with NAV. Superior image quality was observed in the middle-distal renal arteries in the right kidneys with no NAV-induced artifacts. Maximal visible artery length was significantly longer with ADIOS versus NAV in the right kidneys. NAV setup was completely eliminated and scan time was significantly shorter with ADIOS on average compared with NAV. CONCLUSION: The proposed ADIOS technique for noncontrast MRA provides high-quality visualization of renal arteries with no diaphragm navigator-induced artifacts, simplified setup, and shorter scan time.


Subject(s)
Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Pattern Recognition, Automated/methods , Renal Artery/anatomy & histology , Respiratory-Gated Imaging Techniques/methods , Adult , Algorithms , Contrast Media , Feedback , Humans , Middle Aged , Online Systems , Reproducibility of Results , Respiratory Mechanics , Sensitivity and Specificity , Signal Processing, Computer-Assisted , Subtraction Technique , Young Adult
10.
J Cardiovasc Magn Reson ; 16: 53, 2014 Jul 25.
Article in English | MEDLINE | ID: mdl-25184808

ABSTRACT

BACKGROUND: Multi-contrast weighted imaging is a commonly used cardiovascular magnetic resonance (CMR) protocol for characterization of carotid plaque composition. However, this approach is limited in several aspects including low slice resolution, long scan time, image mis-registration, and complex image interpretation. In this work, a 3D CMR technique, named Multi-contrast Atherosclerosis Characterization (MATCH), was developed to mitigate the above limitations. METHODS: MATCH employs a 3D spoiled segmented fast low angle shot readout to acquire data with three different contrast weightings in an interleaved fashion. The inherently co-registered image sets, hyper T1-weighting, gray blood, and T2-weighting, are used to detect intra-plaque hemorrhage (IPH), calcification (CA), lipid-rich necrotic core (LRNC), and loose-matrix (LM). The MATCH sequence was optimized by computer simulations and testing on four healthy volunteers and then evaluated in a pilot study of six patients with carotid plaque, using the conventional multi-contrast protocol as a reference. RESULTS: On MATCH images, the major plaque components were easy to identify. Spatial co-registration between the three image sets with MATCH was particularly helpful for the reviewer to discern co-existent components in an image and appreciate their spatial relation. Based on Cohen's kappa tests, moderate to excellent agreement in the image-based or artery-based component detection between the two protocols was obtained for LRNC, IPH, CA, and LM, respectively. Compared with the conventional multi-contrast protocol, the MATCH protocol yield significantly higher signal contrast ratio for IPH (3.1±1.3 vs. 0.4±0.3, p<0.001) and CA (1.6±1.5 vs. 0.7±0.6, p=0.012) with respect to the vessel wall. CONCLUSIONS: To the best of our knowledge, the proposed MATCH sequence is the first 3D CMR technique that acquires spatially co-registered multi-contrast image sets in a single scan for characterization of carotid plaque composition. Our pilot clinical study suggests that the MATCH-based protocol may outperform the conventional multi-contrast protocol in several respects. With further technical improvements and large-scale clinical validation, MATCH has the potential to become a CMR method for assessing the risk of plaque disruption in a clinical workup.


Subject(s)
Carotid Arteries/pathology , Carotid Stenosis/diagnosis , Contrast Media , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Plaque, Atherosclerotic , Aged , Algorithms , Carotid Stenosis/pathology , Computer Simulation , Feasibility Studies , Fibrosis , Hemorrhage/diagnosis , Hemorrhage/pathology , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Models, Cardiovascular , Necrosis , Pilot Projects , Predictive Value of Tests , Reproducibility of Results , Signal-To-Noise Ratio , Vascular Calcification/diagnosis , Vascular Calcification/pathology
11.
J Magn Reson Imaging ; 40(3): 674-81, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24214467

ABSTRACT

PURPOSE: To determine whether readout-segmented echo-planar diffusion imaging (RESOLVE) improves separation of malignant versus benign lesions compared to standard single-shot echo-planar imaging (ss-EPI) on BI-RADS 4/5 lesions detected on breast magnetic resonance imaging (MRI). MATERIALS AND METHODS: Consecutive 3T breast MRI studies with BI-RADS 4/5 designation and subsequent biopsy or benign mastectomy were retrospectively identified. Freehand regions of interest (ROIs) were drawn on lesions and also on normal background fibroglandular tissue for comparison. Lesion-to-background contrast was evaluated by normalizing signal intensity of the lesion ROI by the normal background tissue ROI at b = 800. Statistical analysis used the Mann-Whitney/Wilcoxon rank-sum test for unpaired and Wilcoxon signed-rank for paired comparisons. RESULTS: Of 38 lesions in 32 patients, 10 were malignant. Lesion-to-background contrast was higher on RESOLVE than ss-EPI (1.80 ± 0.71 vs. 1.62 ± 0.63, P = 0.03). Mean apparent diffusion coefficient (ADC) was the same or lower on RESOLVE than ss-EPI, and this effect was largest in malignant lesions (RESOLVE 0.90 ± 0.13; ss-EPI 1.00 ± 0.13; median difference -0.10 (95% confidence interval [CI]: -0.17, -0.02) × 10(-3) mm(2) /sec; P = 0.014). By either diffusion method, there was a statistically significant difference between benign and malignant mean ADC (P < 0.001). CONCLUSION: Increased lesion-to-background contrast and improved separation of benign from malignant lesions by RESOLVE compared to standard diffusion suggests that RESOLVE may show promise as an adjunct to clinical breast MRI.


Subject(s)
Breast Neoplasms/pathology , Diffusion Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Biopsy , Contrast Media , Diagnosis, Differential , Echo-Planar Imaging , Female , Gadolinium DTPA , Humans , Image Interpretation, Computer-Assisted , Middle Aged , Retrospective Studies , Sensitivity and Specificity
12.
Magn Reson Med ; 71(5): 1771-83, 2014 May.
Article in English | MEDLINE | ID: mdl-23801456

ABSTRACT

PURPOSE: We propose a compressed-sensing (CS) technique based on magnitude image subtraction for high spatial and temporal resolution dynamic contrast-enhanced MR angiography (CE-MRA). METHODS: Our technique integrates the magnitude difference image into the CS reconstruction to promote subtraction sparsity. Fully sampled Cartesian 3D CE-MRA datasets from 6 volunteers were retrospectively under-sampled and three reconstruction strategies were evaluated: k-space subtraction CS, independent CS, and magnitude subtraction CS. The techniques were compared in image quality (vessel delineation, image artifacts, and noise) and image reconstruction error. Our CS technique was further tested on seven volunteers using a prospectively under-sampled CE-MRA sequence. RESULTS: Compared with k-space subtraction and independent CS, our magnitude subtraction CS provides significantly better vessel delineation and less noise at 4× acceleration, and significantly less reconstruction error at 4× and 8× (P < 0.05 for all). On a 1-4 point image quality scale in vessel delineation, our technique scored 3.8 ± 0.4 at 4×, 2.8 ± 0.4 at 8×, and 2.3 ± 0.6 at 12× acceleration. Using our CS sequence at 12× acceleration, we were able to acquire dynamic CE-MRA with higher spatial and temporal resolution than current clinical TWIST protocol while maintaining comparable image quality (2.8 ± 0.5 vs. 3.0 ± 0.4, P = NS). CONCLUSION: Our technique is promising for dynamic CE-MRA.


Subject(s)
Arteries/physiology , Data Compression/methods , Gadolinium , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/methods , Organometallic Compounds , Subtraction Technique , Algorithms , Arteries/anatomy & histology , Blood Flow Velocity/physiology , Contrast Media , Humans , Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
13.
Magn Reson Imaging ; 30(9): 1257-67, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22770687

ABSTRACT

Three dimensional bilateral imaging is the standard for most clinical breast dynamic contrast-enhanced (DCE) MRI protocols. Because of high spatial resolution (sRes) requirement, the typical 1-2 min temporal resolution (tRes) afforded by a conventional full-k-space-sampling gradient echo (GRE) sequence precludes meaningful and accurate pharmacokinetic analysis of DCE time-course data. The commercially available, GRE-based, k-space undersampling and data sharing TWIST (time-resolved angiography with stochastic trajectories) sequence was used in this study to perform DCE-MRI exams on thirty one patients (with 36 suspicious breast lesions) before their biopsies. The TWIST DCE-MRI was immediately followed by a single-frame conventional GRE acquisition. Blinded from each other, three radiologist readers assessed agreements in multiple lesion morphology categories between the last set of TWIST DCE images and the conventional GRE images. Fleiss' κ test was used to evaluate inter-reader agreement. The TWIST DCE time-course data were subjected to quantitative pharmacokinetic analyses. With a four-channel phased-array breast coil, the TWIST sequence produced DCE images with 20 s or less tRes and ~ 1.0×1.0×1.4 mm(3) sRes. There were no significant differences in signal-to-noise (P=.45) and contrast-to-noise (P=.51) ratios between the TWIST and conventional GRE images. The agreements in morphology evaluations between the two image sets were excellent with the intra-reader agreement ranging from 79% for mass margin to 100% for mammographic density and the inter-reader κ value ranging from 0.54 (P<.0001) for lesion size to 1.00 (P<.0001) for background parenchymal enhancement. Quantitative analyses of the DCE time-course data provided higher breast cancer diagnostic accuracy (91% specificity at 100% sensitivity) than the current clinical practice of morphology and qualitative kinetics assessments. The TWIST sequence may be used in clinical settings to acquire high spatiotemporal resolution breast DCE-MRI images for both precise lesion morphology characterization and accurate pharmacokinetic analysis.


Subject(s)
Breast Neoplasms/pathology , Contrast Media/pharmacology , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Angiography , Biopsy/methods , Breast Neoplasms/diagnosis , Contrast Media/pharmacokinetics , Female , Humans , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Signal-To-Noise Ratio , Stochastic Processes , Time Factors
14.
AJR Am J Roentgenol ; 196(3): 702-11, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21343517

ABSTRACT

OBJECTIVE: The objective of our study was to assess the feasibility and diagnostic performance of time-resolved MR angiography (MRA) in the pretreatment evaluation of peripheral vascular malformations at 1.5 T. SUBJECTS AND METHODS: Twenty-two consecutive patients (15 women and seven men; mean age, 22.1 ± 12.1 years) who were known or suspected to have vascular malformations were studied using time-resolved MRA with interleaved stochastic trajectories and parallel acquisition followed by conventional MRA (n = 12). All studies were performed on a 1.5-T whole-body MR system. Image sets of time-resolved and conventional MRA were independently reviewed by two observers for image quality, level of confidence and presence, location, and classification of vascular malformations. The interobserver agreement was calculated using conventional MRA as the standard of reference. RESULTS: On the basis of time-resolved MRA, nine of the lesions were categorized as high-flow arteriovenous malformations (AVMs), the remaining 13 lesions were categorized as low-flow vascular malformations or hemangiomas. There was no significant difference in the image quality grading scores between the two observers for time-resolved MRA (p = 0.61) and conventional MRA (p = 0.54). The kappa coefficient revealed good agreement (κ = 0.76) between time-resolved MRA and conventional MRA. Both observers visualized fine vascular details with higher confidence in two patients on conventional MRA. The additional functional information regarding feeding artery and flow patterns provided by time-resolved MRA was confirmed by digital subtraction in all nine cases. CONCLUSION: Time-resolved MRA provided the temporal information needed for the appropriate classification of vascular malformations, enabling visualization of both the arterial feeders and draining veins. Furthermore, time-resolved MRA has the potential to be used as an initial and screening diagnostic tool obviating conventional MRA to categorize these lesions and determine their extent to correctly guide treatment.


Subject(s)
Arteriovenous Malformations/diagnosis , Hemangioma/diagnosis , Imaging, Three-Dimensional , Magnetic Resonance Angiography/methods , Peripheral Vascular Diseases/diagnosis , Vascular Neoplasms/diagnosis , Contrast Media/administration & dosage , Feasibility Studies , Female , Humans , Male , Statistics, Nonparametric , Young Adult
15.
J Magn Reson Imaging ; 33(1): 71-6, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21182123

ABSTRACT

PURPOSE: To evaluate the feasibility of low-dose, 3D time-resolved contrast-enhanced magnetic resonance angiography (TR-CEMRA) in the assessment of the supraaortic vessel, and to compare the results with high-resolution contrast-enhanced MRA (HR-CEMRA). MATERIALS AND METHODS: This was an Institutional Review Board-approved retrospective study. Forty-five consecutive patients underwent contrast-enhanced 3D TR-CEMRA and 3D HR-CEMRA for evaluation of neurovascular disease at 3.0 T. Gadobutrol was administered at a constant dose of 1 mL for TR-CEMRA (independent of patient weight), and 0.1 mmol/kg for HR-CEMRA. Two readers evaluated image quality using a four-point scale (from 0 = excellent to 3 = nondiagnostic), and subsequently graded each stenosis into clinically relevant categories: normal (0%), mild stenosis (<50%), moderate to severe (>50%), and occlusion. RESULTS: The overall image quality for low-dose TR-CEMRA was in the diagnostic range (median 0, range 0-3). On the grading of stenosis, TR-CEMRA using the TWIST sequence correlated with HR-CEMRA (r = 0.668, P < 0.001). In terms of the comparison of TR-CEMRA with HR-CEMRA, of the 675 supraaortic arterial segments evaluated for stenosis or occlusion, agreement occurred in 611 of 675 (90.5%), overestimation in 41 of 675 (6.1%), and underestimation 23 of 675 (3.4%). CONCLUSION: TR-CEMRA achieved by administration of a small contrast dose (1 cc) yields rapid and important functional and anatomical information in the evaluation of supraaortic arteries. Due to limited spatial resolution, TR-CEMRA at the current parameters has a tendency to overestimate the stenosis of smaller intracranial arteries compared to HR-CEMRA.


Subject(s)
Aorta/pathology , Aortic Valve Stenosis/pathology , Cerebrovascular Disorders/pathology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Organometallic Compounds/administration & dosage , Adolescent , Adult , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Cerebrovascular Disorders/etiology , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Female , Humans , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic , Young Adult
16.
Invest Radiol ; 45(11): 708-14, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20548241

ABSTRACT

OBJECTIVES: The combination of parallel acquisition (generalized autocalibrating partially parallel acquisitions) and time-resolved three-dimensional (3D) view-sharing techniques is a promising tool for dynamic contrast-enhanced 3D-magnetic resonance angiography (MRA). We evaluated the influence of different k-space acquisition strategies on image quality for a recently developed time-resolved echo-shared angiographic technique during a contrast-enhanced 3D-MRA of the thoracic vessels. MATERIALS AND METHODS: In 20 patients (16 men, 4 women; range, 28-75 years), 2 dynamic MRA protocols with different k-space acquisition strategies were performed on a 1.5-T whole-body scanner (MAGNETOM Avanto, Siemens AG, Erlangen, Germany) during injection of 5 mL (flow-rate, 3 mL/s) gadobutrol. For protocol 1, the central-region which was updated with every cycle included 20% of the entire k-space (protocol 2: 10%), the peripheral-region was undersampled by a factor of 10 (protocol 2: 5%). Image quality and details were compared visually. Signal-to-noise ratio and sharpness of vessel borders were estimated. RESULTS: Morphologic and functional assessment of the pulmonary arteries and the aorta was significantly improved for protocol 1. The sharpness of vessel borders (3.3 mm vs. 4.1 mm; P = 0.001), image quality, and the visibility of image details were significantly improved for protocol 1 compared with protocol 2. CONCLUSION: The size of the central region that is updated for every frame seems to be more crucial for image quality of echo-shared angiographic techniques than the sampling density in the periphery of the k-space.


Subject(s)
Aorta/pathology , Contrast Media , Magnetic Resonance Angiography/instrumentation , Pulmonary Artery/pathology , Adult , Aged , Aorta/diagnostic imaging , Feasibility Studies , Female , Humans , Imaging, Three-Dimensional , Magnetic Resonance Angiography/methods , Male , Middle Aged , Pulmonary Artery/diagnostic imaging , Radiographic Image Enhancement , Radionuclide Imaging , Time Factors
17.
Acad Radiol ; 17(5): 564-76, 2010 May.
Article in English | MEDLINE | ID: mdl-20171907

ABSTRACT

RATIONALE AND OBJECTIVES: The aims of this study were to evaluate the effectiveness of low-dose, contrast-enhanced (CE), time-resolved, three-dimensional magnetic resonance angiography (MRA) in the assessment of the abdominal aorta and its major branches at 3 T and to compare the results with those of high-spatial resolution CE MRA. MATERIALS AND METHODS: Twenty-two consecutive patients (eight men, 14 women; mean age, 43.9 +/- 17.9 years) underwent CE time-resolved three-dimensional MRA and high-spatial resolution three-dimensional MRA. Studies were performed using a 3-T magnetic resonance system; gadolinium-based contrast medium was administered at a dose of 3 to 5 mL for time-resolved MRA, followed by 0.1 mmol/kg gadopentetate dimeglumine for single-phase CE MRA. For analysis purposes, the abdominal arterial system was divided into 11 arterial segments, and image quality as well as the presence and degree of vascular pathology were evaluated by two independent magnetic resonance radiologists. RESULTS: A total of 242 arterial segments were visualized with good image quality. Time-resolved MRA was able to visualize the majority of arterial segments with good definition in the diagnostic range. Vascular pathologies (stenosis, occlusion) or abnormal vascular anatomy was detected in 19 arterial segments, with good interobserver agreement (kappa = 0.78). All image findings were detected with time-resolved CE MRA by both observers and were confirmed by correlative imaging. CONCLUSION: Low-dose, time-resolved MRA at 3 T yields rapid and important anatomic and functional information in the evaluation of the abdominal vasculature. Because of its limited spatial resolution, time-resolved MRA is inferior to CE MRA in demonstrating fine vascular details.


Subject(s)
Aorta, Abdominal/pathology , Gadolinium DTPA/administration & dosage , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/methods , Adult , Aged , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Dose-Response Relationship, Radiation , Female , Humans , Male , Middle Aged , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity , Young Adult
18.
J Magn Reson Imaging ; 31(3): 663-72, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20187210

ABSTRACT

PURPOSE: To assess added value of a new time-resolved technique with temporal interpolation and stochastic spiral trajectory through k-space and parallel imaging (TR-MRA) to conventional bolus chase MRA (BC-MRA) for infragenual peripheral artery evaluation. MATERIALS AND METHODS: An institutional review board-approved retrospective review of peripheral arterial disease patients was performed. Infragenual TR-MRA and BC-MRA were performed in 26 patients over four months. Two readers individually assessed image quality, diagnostic confidence, and stenosis severity and length in 13 defined below knee segments, first with BC-MRA alone, and then with a combined BC-MRA and TR-MRA reading (BC+TR-MRA). Perceived contribution of TR-MRA was rated by each reader. The reference standard was a consensus reading of both sequences. Catheter angiographic (CA) correlation was available in 6 patients. RESULTS: A total of 646 infragenual segments in 51 extremities were evaluated. Image quality and diagnostic confidence were superior for BC+TR-MRA compared with BC-MRA alone (P < 0.001). Adding TR-MRA improved sensitivity (85.7% versus 80.7%; P < 0.05) and diagnostic accuracy (88.1% versus 85.4%; P < 0.05) for hemodynamically significant stenosis. Venous contamination (0% versus 13.1% segments) and motion (0.9% versus 8.0%) were decreased for BC+TR-MRA versus BC-MRA alone, P < 0.01. For BC+TR-MRA, TR-MRA was rated more useful than BC-MRA in 30/51 legs (58.8%). TR-MRA identified retrograde flow in 5 segments. Where available, there was high concordance between CA and BC+TR-MRA (91.6%) for stenosis. CONCLUSION: Adding TR-MRA with temporal interpolation and stochastic spiral trajectories to bolus chase MRA improves image quality, diagnostic confidence and accuracy. It provides hemodynamic information and minimizes venous contamination and patient motion.


Subject(s)
Algorithms , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Lower Extremity/blood supply , Magnetic Resonance Angiography/methods , Peripheral Vascular Diseases/diagnosis , Adult , Aged , Aged, 80 and over , Data Interpretation, Statistical , Humans , Middle Aged , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity , Stochastic Processes
19.
J Alzheimers Dis ; 20(1): 333-41, 2010.
Article in English | MEDLINE | ID: mdl-20164577

ABSTRACT

Prevalent gene variants involved in iron metabolism [hemochromatosis (HFE) H63D and transferrin C2 (TfC2)] have been associated with higher risk and earlier age at onset of Alzheimer's disease (AD), especially in men. Brain iron increases with age, is higher in men, and is abnormally elevated in several neurodegenerative diseases, including AD and Parkinson's disease, where it has been reported to contribute to younger age at onset in men. The effects of the common genetic variants (HFE H63D and/or TfC2) on brain iron were studied across eight brain regions (caudate, putamen, globus pallidus, thalamus, hippocampus, white matter of frontal lobe, genu, and splenium of corpus callosum) in 66 healthy adults (35 men, 31 women) aged 55 to 76. The iron content of ferritin molecules (ferritin iron) in the brain was measured with MRI utilizing the Field Dependent Relaxation Rate Increase (FDRI) method. 47% of the sample carried neither genetic variant (IRON-) and 53% carried one and/or the other (IRON+). IRON+ men had significantly higher FDRI compared to IRON- men (p=0.013). This genotype effect was not observed in women who, as expected, had lower FDRI than men. This is the first published evidence that these highly prevalent genetic variants in iron metabolism genes can influence brain iron levels in men. Clinical phenomena such as differential gender-associated risks of developing neurodegenerative diseases and age at onset may be associated with interactions between iron genes and brain iron accumulation. Clarifying mechanisms of brain iron accumulation may help identify novel interventions for age-related neurodegenerative diseases.


Subject(s)
Brain/metabolism , Ferritins/metabolism , Genetic Variation/genetics , Histocompatibility Antigens Class I/genetics , Membrane Proteins/genetics , Mutation/genetics , Sex Characteristics , Aged , Aging/genetics , Aging/pathology , Brain/anatomy & histology , Brain Mapping , Female , Gene Expression Regulation/genetics , Hemochromatosis Protein , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Multivariate Analysis , Neurodegenerative Diseases/etiology , Neurodegenerative Diseases/metabolism
20.
Eur Radiol ; 20(6): 1311-20, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20013276

ABSTRACT

OBJECTIVES: The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. METHODS: Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. RESULTS: Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). CONCLUSION: Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material.


Subject(s)
Algorithms , Aorta, Thoracic/pathology , Gadolinium DTPA , Heart Valve Diseases/diagnosis , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Adult , Aged , Contrast Media , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...