Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Front Surg ; 11: 1365535, 2024.
Article in English | MEDLINE | ID: mdl-38948482

ABSTRACT

Introduction: Postmortem computed tomography (pmCT) prior to forensic autopsy has become increasingly important in recent decades, especially in forensic documentation of single injuries, injury patterns, and causes of death. Postmortem decomposition gas formation can also be detected in pmCT scans, which might affect cochlear implant research in postmortem human temporal bones (TBs). Material and methods: Fifty non-putrefied hanging fatalities within a 2-year period (January 2017 to December 2019) were included with 100 TBs. Each body underwent whole-body pmCT prior to forensic autopsy. PmCT scans were analyzed with respect to the presence of intracochlear gas despite the lack of putrefaction at autopsy by an experienced fellow neurotologist. Results: PmCT revealed gas formation in two individuals despite the lack of head trauma and putrefaction at postmortem examination and autopsy. Both individuals showed enclosed gas in the vestibule and the cochlea on both sides. Discussion: Intracochlear gas formation, most likely related to decomposition, may occur despite the lack of putrefaction at postmortem examination and autopsy and can be detected by pmCT. This finding seems to be rather rare in non-traumatic death cases but might affect cochlear pressure research in postmortem human TB.

2.
J Otolaryngol Head Neck Surg ; 53: 19160216241250351, 2024.
Article in English | MEDLINE | ID: mdl-38888946

ABSTRACT

OBJECTIVE: The long-term preservation of residual hearing after cochlear implantation has become a major goal over the past few years. The aim of the present study was to evaluate residual hearing in the long-term follow-up using mid-scala electrodes. METHODS: In this retrospective, single-center study, we collected data from 27 patients who were implanted between 2014 and 2015 with residual hearing in the low-frequency range using a mid-scala electrode. Measurements of the hearing thresholds were carried out directly postoperatively (day 1 after surgery) and in the long-term follow-up 43.7 ± 6.9 months. The calculation of the extent of audiological hearing preservation was determined using the HEARRING group formula by Skarsynski. RESULTS: Postoperative preservation of residual hearing was achieved in 69.2% of the cases in the low-frequency range between 250 Hz and 1 kHz, of which 89.5% of the patients had frequencies that suggested using electroacoustic stimulation (EAS). In the long-term follow-up, 30.8% of the patients showed residual hearing; however, 57.1% had apparently benefited from EAS. CONCLUSION: Preservation of residual hearing is feasible in the long term using mid-scala electrodes. Postoperatively, there is over the half of patients who benefit from an EAS strategy. The long-term follow-up shows a certain decrease in residual hearing. However, these results are comparable to studies relating to other types of electrodes. Further research should be conducted in future to better evaluate hearing loss in long-term follow-up, compared to direct postoperative audiological results.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Retrospective Studies , Male , Female , Cochlear Implantation/methods , Middle Aged , Adult , Follow-Up Studies , Hearing/physiology , Aged , Auditory Threshold , Adolescent , Child, Preschool , Treatment Outcome , Child , Electrodes, Implanted , Young Adult , Prosthesis Design , Hearing Loss/surgery , Time Factors
3.
J Clin Med ; 12(17)2023 Aug 24.
Article in English | MEDLINE | ID: mdl-37685566

ABSTRACT

The surgical options for patients with single-sided Menière's disease and functional deafness are challenging. Our case series reports the outcomes of surgical treatments of patients with single-sided Menière's disease and functional deafness. These patients have undergone a one-staged occlusion of all semi-circular canals and cochlear implantation. Five patients (four female and one male; 62 ± 8.2 years with a range from 50 to 72 years) with single-sided Menière's disease and functional deafness were included in this study. In all cases, the patients suffered from frequent rotational vertigo episodes for many years. Other treatment options (e.g., medication) had not yet been successful. Preoperatively, the Dizziness Handicap Inventory (DHI) of all patients indicated severe emotional, physical, and functional deficits. Patients showed a functional (near-total) deafness of the affected ear in all cases. All patients were supplied with cochlear implants in combination with a triple occlusion of all semi-circular canals in a one-stage procedure. After a short period of increased dizziness following surgery and after the activation of the cochlear implant and CI rehabilitation (auditory-verbal therapy), vertigo control and an adequate audiological outcome were achieved. The DHI showed a constant decrease after surgery. The combination of a triple semi-circular canal occlusion and cochlear implantation can be an efficient treatment for patients with single-sided Menière's disease.

4.
Audiol Neurootol ; 26(4): 281-286, 2021.
Article in English | MEDLINE | ID: mdl-33647910

ABSTRACT

OBJECTIVE: Atraumatic cochlear implantation (CI) and insertion of the electrode in particular are major goals of recent CI surgery. Perimodiolar electrode arrays need a stylet or exosheath for insertion. The sheath can influence the intracochlear pressure changes during insertion of the electrode. The aim of this study was to modify the insertion sheath to optimize intracochlear pressure changes. METHODS: In an artifical cochlear model, 7 different modified insertion sheaths were used. The intracochlear pressure was measured with a micro-optical sensor in the apical part of the model cochlea. RESULTS: Significant lower intracochlear pressure changes were observed when the apical part of the insertion sheath was either shortened or tapered. Modification of the stopper does influence the intracochlear pressure significantly. CONCLUSION: Modification of the insertion sheath leads to lower intracochlear pressure gain. The differences and impact on intracochlear pressure changes found in this study underline the importance of even subtle modifications of the electrode insertion technique.


Subject(s)
Cochlear Implantation , Cochlear Implants , Cochlea/surgery , Electrodes, Implanted , Pressure
5.
Laryngoscope Investig Otolaryngol ; 4(4): 441-445, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31453355

ABSTRACT

OBJECTIVE: Different aspects should be considered to achieve an atraumatic insertion of cochlear implant electrode arrays as an important surgical goal. Intracochlear pressure changes are known to influence the preservation of residual hearing. By using the intraoperative "pullback technique," an electrode position closer to the modiolus can be achieved than without the pullback. The aim of the present study was therefore to investigate to what extent the pullback technique can influence intracochlear pressure changes. METHODS: Insertions of cochlear implant electrodes were performed in an artificial cochlear model with two different perimodiolar arrays. Intracochlear pressure changes were recorded with a micro-optical pressure sensor positioned in the apical part of the cochlear. After complete insertion of the electrode array, a so-called pullback of the electrode was performed. RESULTS: Statistically significant pressure differences were measured if the electrode array was wet (ie, moisturized) during the pullback. Relative pressure changes in electrodes with smaller total volume are lower than pressure changes in larger electrodes. CONCLUSION: The preservation of residual hearing and, thus, the resulting postoperative audiological outcome has a major impact on the quality of life of the patients and has become of utmost importance. Intracochlear pressure changes during the pullback manoeuver are small in absolute terms, but can even be still reduced statistically significantly by a moistening the electrode before insertion. Using the pullback technique in cases with residual hearing does not affect the probability of preservation of residual hearing but could lead to a better audiological outcome. LEVEL OF EVIDENCE: NA.

SELECTION OF CITATIONS
SEARCH DETAIL
...