Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Water Sci Technol ; 62(5): 1129-35, 2010.
Article in English | MEDLINE | ID: mdl-20818055

ABSTRACT

This research investigated the effects of co- and counter-current flow patterns on oil-water-solid separation efficiencies of a circular separator with inclined coalescence mediums. Oil-water-solid separations were tested at different influent concentrations and flowrates. Removal efficiencies increased as influent flowrate decreased, and their correlationship can be represented by power equations. These equations were used to predict the required flowrate, Q(ss50), for a given influent suspended solids concentration C(iss) to achieve the desired effluent suspended solids concentration, C(ess) of 50 mg/L, to meet environmental discharge requirements. The circular separator with counter-current flow was found to attend removal efficiencies relatively higher as compared to the co-current flow. As compared with co-current flow, counter-current flow Q(ss50) was approximately 1.65 times higher than co-current flow. It also recorded 13.16% higher oil removal at influent oil concentration, C(io) of 100 mg/L, and approximately 5.89% higher TSS removal at all influent flowrates. Counter-current flow's better removal performances were due to its higher coalescing area and constant interval between coalescence plate layers.


Subject(s)
Oils/chemistry , Particulate Matter/chemistry , Water Pollutants, Chemical/chemistry , Water Purification/methods , Water Movements
2.
J Air Waste Manag Assoc ; 47(4): 491-500, 1997 Apr.
Article in English | MEDLINE | ID: mdl-28065154

ABSTRACT

The probabilistic National Ambient Air Quality Standards (NAAQS) Exposure Model applied to carbon monoxide (pNEM/CO) was developed by the U.S. Environmental Protection Agency (EPA) to estimate frequency distributions of population exposure to carbon monoxide (CO) and the resulting carboxyhemoglobin (COHb) levels. To evaluate pNEM/CO, the model was set up to simulate CO exposure data collected during a Denver Personal Exposure Monitoring Study (PEM) conducted during the winter of 1982-1983. This paper compares computer-simulated exposure distributions obtained by pNEM/CO with the observed cumulative relative frequency distributions of population exposure to CO from 779 people in the Denver PEM study. The subjects were disaggregated into two categories depending upon whether they lived in a home with a gas stove or an electric stove. The observed and predicted population exposure frequency distributions were compared in terms of 1-hr daily maximum exposure (1DME) and 8-hr daily maximum moving average exposure (8DME) for people living in homes with gas stove or an electric stove. For 1DME, the computer-simulated results from pNEM/CO agreed most closely within the range of 6-13 ppm, but overestimated occurrences at low exposure (<6 ppm) and underestimated occurrences at high exposure (>13 ppm). For 8DME, the predicted exposures agreed best with observed exposures in the range of CO concentration between 5.5 and 7 ppm, and over-predicted occurrences below 5.5 ppm and under-predicted occurrences above 7 ppm.

3.
J Air Waste Manag Assoc ; 47(3): 491-500, 1997 Mar.
Article in English | MEDLINE | ID: mdl-29081285

ABSTRACT

The probabilistic National Ambient Air Quality Standards (NAAQS) Exposure Model applied to carbon monoxide (pNEM/CO) was developed by the U.S. Environmental Protection Agency (EPA) to estimate frequency distributions of population exposure to carbon monoxide (CO) and the resulting carboxyhemoglobin (COHb) levels. To evaluate pNEM/CO, the model was set up to simulate CO exposure data collected during a Denver Personal Exposure Monitoring Study (PEM) conducted during the winter of 1982-1983. This paper compares computer-simulated exposure distributions obtained by pNEM/CO with the observed cumulative relative frequency distributions of population exposure to CO from 779 people in the Denver PEM study. The subjects were disaggregated into two categories depending upon whether they lived in a home with a gas stove or an electric stove. The observed and predicted population exposure frequency distributions were compared in terms of 1-hr daily maximum exposure (1DME) and 8-hr daily maximum moving average exposure (8DME) for people living in homes with gas stove or an electric stove. For 1DME, the computer-simulated results from pNEM/CO agreed most closely within the range of 6-13 ppm, but overestimated occurrences at low exposure (<6 ppm) and underestimated occurrences at high exposure (>13 ppm). For 8DME, the predicted exposures agreed best with observed exposures in the range of CO concentration between 5.5 and 7 ppm, and over-predicted occurrences below 5.5 ppm and under-predicted occurrences above 7 ppm.

SELECTION OF CITATIONS
SEARCH DETAIL
...