Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 193
Filter
2.
Gastrointest Endosc Clin N Am ; 34(3): 511-522, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38796296

ABSTRACT

EDEE is a relatively safe and effective procedure when performed by expert endoscopists to establish pancreaticobiliary access in patients who have failed, or are not candidates for, traditional ERCP or alternative drainage modalities. Careful preprocedural planning with attention to the patient's specific postsurgical anatomy can optimize outcomes and minimize AEs.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Humans , Cholangiopancreatography, Endoscopic Retrograde/methods , Drainage/methods
3.
Nat Commun ; 15(1): 3709, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38697962

ABSTRACT

One of the most effective ways to advance the performance of quantum computers and quantum sensors is to increase the number of qubits or quantum resources in the system. A major technical challenge that must be solved to realize this goal for trapped-ion systems is scaling the delivery of optical signals to many individual ions. In this paper we demonstrate an approach employing waveguides and multi-mode interferometer splitters to optically address multiple 171Yb+ ions in a surface trap by delivering all wavelengths required for full qubit control. Measurements of hyperfine spectra and Rabi flopping were performed on the E2 clock transition, using integrated waveguides for delivering the light needed for Doppler cooling, state preparation, coherent operations, and detection. We describe the use of splitters to address multiple ions using a single optical input per wavelength and use them to demonstrate simultaneous Rabi flopping on two different transitions occurring at distinct trap sites. This work represents an important step towards the realization of scalable integrated photonics for atomic clocks and trapped-ion quantum information systems.

4.
Gastroenterol Rep (Oxf) ; 12: goae039, 2024.
Article in English | MEDLINE | ID: mdl-38681751

ABSTRACT

Background: Visceral fat represents a metabolically active entity linked to adverse metabolic sequelae of obesity. We aimed to determine if celiac artery mesenteric fat thickness can be reliably measured during endoscopic ultrasound (EUS), and if these measurements correlate with metabolic disease burden. Methods: This was a retrospective analysis of patients who underwent celiac artery mesenteric fat measurement with endosonography (CAMEUS) measurement at a tertiary referral center, and a validation prospective trial of patients with obesity and nonalcoholic steatohepatitis who received paired EUS exams with CAMEUS measurement before and after six months of treatment with an intragastric balloon. Results: CAMEUS was measured in 154 patients [56.5% females, mean age 56.5 ± 18.0 years, body mass index (BMI) 29.8 ± 8.0 kg/m2] and was estimated at 14.7 ± 6.5 mm. CAMEUS better correlated with the presence of non-alcoholic fatty liver disease (NAFLD) (R2 = 0.248, P < 0.001) than BMI (R2 = 0.153, P < 0.001), and significantly correlated with metabolic parameters and diseases. After six months of intragastric balloon placement, the prospective cohort experienced 11.7% total body weight loss, 1.3 points improvement in hemoglobin A1c (P = 0.001), and a 29.4% average decrease in CAMEUS (-6.4 ± 5.2 mm, P < 0.001). CAMEUS correlated with improvements in weight (R2 = 0.368), aspartate aminotransferase to platelet ratio index (R2 = 0.138), and NAFLD activity score (R2 = 0.156) (all P < 0.05). Conclusions: CAMEUS is a novel measure that is significantly correlated with critical metabolic indices and can be easily captured during routine EUS to risk-stratify susceptible patients. This station could allow for EUS access to sampling and therapeutics of this metabolic region.

5.
J Clin Gastroenterol ; 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38648501

ABSTRACT

BACKGROUND AND AIMS: Endoscopic ultrasound shear wave elastography (EUS-SWE) is a novel modality for liver stiffness measurement. The aims of this study are to evaluate the performance and reliability of EUS-SWE for detecting advanced liver disease in a prospective cohort. METHODS: EUS-SWE measurements were prospectively obtained from patients undergoing EUS between August 2020 and March 2023. Liver stiffness measurements were compared between patients with and without advanced liver disease (ALD), defined as stage ≥3, to determine diagnostic accuracy for advanced fibrosis and portal hypertension. Logistic regression was performed to identify variables that impact the reliability of EUS-SWE readings. Select patients underwent paired magnetic resonance elastography (MRE) for liver fibrosis correlation. RESULTS: Patients with ALD demonstrated higher liver stiffness compared to healthy controls (left lobe: 17.6 vs. 12.7 kPa, P<0.001; median right lobe: 24.8 vs. 11.0 kPa, P<0.001). The area under the receiver operator characteristic (AUROC) for the detection of ALD was 0.73 and 0.80 for left and right lobe measurements, respectively. General anesthesia was associated with reliable EUS-SWE liver readings (odds ratio: 2.73, 95% CI: 1.07-7.39, P=0.040). Left lobe measurements correlated significantly with MRE with an increase of 0.11 kPa (95% CI: 0.05-0.17 kPA) for every 1 kPa increase on EUS-SWE. D. CONCLUSIONS: SWE is a promising technology that can readily be incorporated into standard EUS examinations for the assessment of ALD.

6.
Endosc Int Open ; 12(3): E341-E343, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38464980
7.
Gastrointest Endosc ; 2024 Jan 04.
Article in English | MEDLINE | ID: mdl-38184119

ABSTRACT

BACKGROUND AND AIMS: Access to new endoscopic treatment modalities often depends on price. To resolve this gap and therefore help to ensure that care delivery can occur on a clinical basis, we aimed to establish the value to insurers of novel hemostatic powder to treat GI tumor bleeding. METHODS: A decision-analytic model developed to assess the impact of endoscopic intervention on the risk of 30-day readmission for GI bleeding from an insurer perspective was adapted to assess GI tumor bleeding with hemostatic powder or standard endoscopic therapy. Costs were derived from Medicare populations. Outcomes were derived from a recent multicenter randomized clinical trial. RESULTS: Costs ranged from $651 to $1613 to treat upper GI tumor bleeding and from $531 to $1014 to treat lower GI tumor bleeding based on risk reduction in 30-day hospital readmission for recurrent bleeding. These valuations should represent medical device and incremental facility costs in addition to incremental physician and staff time. CONCLUSIONS: Coverage for novel endoscopic hemostatic powder therapy seems cost-saving to insurers.

8.
Gastrointest Endosc ; 99(6): 1032-1034, 2024 06.
Article in English | MEDLINE | ID: mdl-38280533

ABSTRACT

BACKGROUND AND AIMS: Balloons are used in EUS to improve visualization. However, data on the safety of latex balloons in patients with latex allergies are limited, and nonlatex alternatives can be costly. We investigated the safety of latex balloon use during EUS. METHODS: A retrospective review was conducted at a tertiary center between 2019 and 2022. Patients with reported latex allergies who underwent linear EUS were included. Baseline demographics, EUS characteristics, and adverse events were collected. The primary outcome was the rate of adverse events. RESULTS: Eighty-seven procedures were performed on 57 unique patients (mean age, 65.3 ± 14.5 years). Latex balloons were used in 59 procedures (67.8%), with only 8 procedures (13.6%) using prophylactic medications. No adverse events occurred during or after procedures, regardless of medication use or history of anaphylaxis. CONCLUSIONS: The use of EUS latex balloons in patients with a latex allergy was associated with no adverse events.


Subject(s)
Endosonography , Latex Hypersensitivity , Humans , Male , Female , Retrospective Studies , Aged , Middle Aged , Latex/adverse effects
9.
VideoGIE ; 9(1): 38-41, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38261900

ABSTRACT

Video 1Contrast instillation into the jejunum using the pre-existing jejunal extension tubing from the PEG with jejunal extension followed by lumen-apposing metal stent deployment under endosonographic vision, securing the gastrojejunostomy.

11.
Gastrointest Endosc ; 99(2): 177-185, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37500019

ABSTRACT

BACKGROUND AND AIMS: Video analysis has emerged as a potential strategy for performance assessment and improvement. We aimed to develop a video-based skill assessment tool for peroral endoscopic myotomy (POEM). METHODS: POEM was deconstructed into basic procedural components through video analysis by an expert panel. A modified Delphi approach and 2 validation exercises were conducted to refine the POEM assessment tool (POEMAT). Twelve assessors used the final POEMAT version to grade 10 videos. Fully crossed generalizability (G) studies investigated the contributions of assessors, endoscopists' performance, and technical elements to reliability. G coefficients below .5 were considered unreliable, between .5 and .7 as modestly reliable, and above .7 as indicative of satisfactory reliability. RESULTS: After task deconstruction, discussions, and the modified Delphi process, the final POEMAT comprised 9 technical elements. G analysis showed low variance for endoscopist performance (.8%-24.9%) and high interrater variability (range, 63.2%-90.1%). The G score was moderately reliable (≥.60) for "submucosal tunneling" and "myotomy" and satisfactorily reliable (≥.70) for "active hemostasis" and "mucosal closure." CONCLUSIONS: We developed and established initial content and response process validity evidence for the POEMAT. Future steps include appraisal of the tool using a wider range of POEM videos to establish and improve the discriminative validity of this tool.


Subject(s)
Digestive System Surgical Procedures , Esophageal Achalasia , Myotomy , Natural Orifice Endoscopic Surgery , Humans , Esophageal Achalasia/surgery , Reproducibility of Results , Treatment Outcome , Esophageal Sphincter, Lower
13.
Surg Obes Relat Dis ; 20(1): 53-61, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37690929

ABSTRACT

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) is technically challenging in patients with Roux-en-Y gastric bypass (RYGB) due to altered anatomy. OBJECTIVE: To compare the procedural and clinical outcomes of 4 different ERCP techniques in RYGB patients. SETTING: Academic tertiary referral center in the United States. METHODS: A retrospective cohort study including patients with RYGB anatomy who underwent an ERCP between January 2015 and September 2020. We compared procedural success and adverse events (AEs) rates of balloon-assisted enteroscopy (BAE), gastrostomy-assisted ERCP (GAE), endoscopic ultrasound (EUS)-directed transgastric ERCP (EDGE), and rendezvous guidewire-assisted ERCP (RGA). RESULTS: Seventy-eight RYGB patients underwent a total of 132 ERCPs. The mean age was 60 ± 11.8 years, with female predominance (85.7%). The ERCP procedures performed were BAE (n = 64; 48.5%), GAE (n = 18; 13.7%), EDGE (n = 25; 18.9%), and RGA (n = 25; 18.9%), with overall procedure success rates of 64.1%, 100%, 89.5%, and 91.7%, respectively. All approaches were superior to BAE (GAE versus BAE, P = .003; EDGE versus BAE, P = .034; RGA versus BAE, P = .011). The overall AE rates were 10.9%, 11.1%, 15.8 %, and 25.0%, respectively. There was no statistical difference in AEs. There were also no differences in bleeding, post-ERCP pancreatitis, and perforation rates between the 4 approaches. CONCLUSION: Procedure success was similar between GAE, RGA, and EDGE, but superior to BAE. AE rates were similar between approaches.


Subject(s)
Cholangiopancreatography, Endoscopic Retrograde , Gastric Bypass , Humans , Female , Middle Aged , Aged , Male , Cholangiopancreatography, Endoscopic Retrograde/methods , Retrospective Studies , Gastric Bypass/adverse effects , Gastric Bypass/methods , Endosonography/methods , Algorithms
14.
Gastrointest Endosc ; 99(1): 104-107, 2024 01.
Article in English | MEDLINE | ID: mdl-37722511

ABSTRACT

BACKGROUND AND AIMS: Coaxial double-pigtail plastic stent (DPPS) placement is often performed within lumen-apposing metal stents (LAMSs) for drainage of pancreatic fluid collections (PFCs) to prevent adverse events (AEs) such as stent occlusion and bleeding. This study compares the safety and outcomes of LAMSs alone versus LAMSs with coaxial DPPSs for PFC management. METHODS: Patients undergoing drainage of a PFC with LAMSs were retrospectively identified and categorized as LAMS or LAMS/DPPS based on initial drainage strategy. The AE rate, AE type, and clinical success were extracted by chart review. RESULTS: One hundred eighty-five individuals (83 LAMS, 102 LAMS/DPPS) were identified. No significant differences were found in rates of clinical success (75.9% LAMS vs 69.6% LAMS/DDPS, P = .34) or overall AEs (15.7% LAMS vs 15.7% LAMS/DPPS, P = .825). CONCLUSIONS: In this comparative single-center study, placement of a coaxial DPPS for drainage of PFCs with LAMSs did not affect rates of AEs or clinical success.


Subject(s)
Pancreatic Diseases , Humans , Retrospective Studies , Pancreatic Diseases/surgery , Pancreatic Diseases/etiology , Stents/adverse effects , Drainage/adverse effects , Hemorrhage/etiology
15.
Gastrointest Endosc ; 2023 Dec 06.
Article in English | MEDLINE | ID: mdl-38065512

ABSTRACT

BACKGROUND AND AIMS: Upper GI bleeding (UGIB) is a common medical emergency associated with high resource utilization, morbidity, and mortality. Timely EGD can be challenging from personnel, resource, and access perspectives. PillSense (EnteraSense Ltd, Galway, Ireland) is a novel swallowed bleeding sensor for the detection of UGIB, anticipated to aid in patient triage and guide clinical decision-making for individuals with suspected UGIB. METHODS: This prospective, open-label, single-arm comparative clinical trial of a novel bleeding sensor for patients with suspected UGIB was performed at a tertiary care center. The PillSense system consists of an optical sensor and an external receiver that processes and displays data from the capsule as "Blood Detected" or "No Blood Detected." Patients underwent EGD within 4 hours of capsule administration; participants were followed up for 21 days to confirm capsule passage. RESULTS: A total of 126 patients were accrued to the study (59.5% male; mean age, 62.4 ± 14.3 years). Sensitivity and specificity for detecting the presence of blood were 92.9% (P = .02) and 90.6% (P < .001), respectively. The capsule's positive and negative predictive values were 74.3% and 97.8%, and positive and negative likelihood ratios were 9.9 and .08. No adverse events or deaths occurred related to the PillSense system, and all capsules were excreted from patients on follow-up. CONCLUSIONS: The PillSense system is safe and effective for detecting the presence of blood in patients evaluated for UGIB before upper GI endoscopy. It is a rapidly deployed tool, with easy-to-interpret results that will affect the diagnosis and triage of patients with suspected UGIB. (Clinical trial registration number: NCT05385224.).

16.
VideoGIE ; 8(11): 474-477, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38026704

ABSTRACT

Background and Aims: Percutaneous gallbladder drainage has traditionally been the reference standard treatment for cholecystitis in patients deemed unfit for surgery. Endoscopic transpapillary gallbladder drainage has emerged as a reliable alternative that offers an internal, incisionless option in nonsurgical patients. The aim of this study was to describe techniques for successful selective cystic duct cannulation and gallbladder drainage during ERCP. Methods: A series of endoscopic transpapillary gallbladder procedures is shown, including endoscopic and fluoroscopic video and images. Each case highlights best practices, devices, and techniques to aid with successful completion of challenging cases. Results: Standard cystic duct cannulation and gallbladder access is described using a standard catheter and a 0.035-inch angled guidewire. Challenges to selective cystic duct cannulation are overcome using various approaches, including using a rotatable catheter system, downsizing to a smaller guidewire, occluding the proximal common hepatic duct with an occlusion balloon, and directly intubating the cystic duct using peroral cholangioscopy. Dilation of the cystic duct is performed using standard devices designed for biliary intervention, but smaller, percutaneous angioplasty balloons are used for small ducts and severe strictures. After dilation, a plastic, double-pigtail stent is deployed across the papilla, and access is reobtained in a similar fashion to place a second, parallel stent. To eliminate the need to re-access the gallbladder after initial stent deployment, a cytology brush catheter is repurposed to obtain dual-wire access within the gallbladder before initial stent deployment. Conclusions: When the fundamentals of ERCP and the techniques described here are used, endoscopic transpapillary gallbladder drainage can be performed safely and effectively to treat cholecystitis in patients who are not surgical candidates.

17.
Clin Cancer Res ; 2023 Oct 18.
Article in English | MEDLINE | ID: mdl-37851080

ABSTRACT

PURPOSE: Pancreatic ductal adenocarcinoma (PDAC) is generally divided in two subtypes, classical and basal. Recently, single cell RNA sequencing has uncovered the co-existence of basal and classical cancer cells, as well as intermediary cancer cells, in individual tumors. The latter remains poorly understood; here, we sought to characterize them using a multimodal approach. EXPERIMENTAL DESIGN: We performed subtyping on a single cell RNA sequencing dataset containing 18 human PDAC samples to identify multiple intermediary subtypes. We generated patient-derived PDAC organoids for functional studies. We compared single cell profiling of matched blood and tumor samples to measure changes in the local and systemic immune microenvironment. We then leveraged longitudinally patient-matched blood to follow individual patients over the course of chemotherapy. RESULTS: We identified a cluster of KRT17-high intermediary cancer cells that uniquely express high levels of CXCL8 and other cytokines. The proportion of KRT17High/CXCL8+ cells in patient tumors correlated with intra-tumoral myeloid abundance, and, interestingly, high pro-tumor peripheral blood granulocytes, implicating local and systemic roles. Patient-derived organoids maintained KRT17High/CXCL8+cells and induced myeloid cell migration in an CXCL8-dependent manner. In our longitudinal studies, plasma CXCL8 decreased following chemotherapy in responsive patients, while CXCL8 persistence portended worse prognosis. CONCLUSIONS: Through single cell analysis of PDAC samples we identified KRT17High/CXCL8+ cancer cells as an intermediary subtype, marked by a unique cytokine profile and capable of influencing myeloid cells in the tumor microenvironment and systemically. The abundance of this cell population should be considered for patient stratification in precision immunotherapy.

18.
iScience ; 26(10): 107915, 2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37790281

ABSTRACT

Older individuals and people with HIV (PWH) were prioritized for COVID-19 vaccination, yet comprehensive studies of the immunogenicity of these vaccines and their effects on HIV reservoirs are not available. Our study on 68 PWH and 23 HIV-negative participants aged 55 and older post-three vaccine doses showed equally strong anti-spike IgG responses in serum and saliva through week 48 from baseline, while PWH salivary IgA responses were low. PWH had diminished live-virus neutralization responses after two vaccine doses, which were 'rescued' post-booster. Spike-specific T cell immunity was enhanced in PWH with normal CD4+ T cell count, suggesting Th1 imprinting. The frequency of detectable HIV viremia increased post-vaccination, but vaccines did not affect the size of the HIV reservoir in most PWH, except those with low-level viremia. Thus, older PWH require three doses of COVID-19 vaccine for maximum protection, while individuals with unsuppressed viremia should be monitored for adverse reactions from HIV reservoirs.

19.
Ther Adv Gastrointest Endosc ; 16: 26317745231200971, 2023.
Article in English | MEDLINE | ID: mdl-37767287

ABSTRACT

Background: Reports suggest that the rate of adverse events (AEs) post-endoscopic sphincterotomy (ES) to be as high as 10%, with gastrointestinal bleeding being most common after post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis. Objective: The aim of this study was to characterize the incidence of bleeding in patients with thrombocytopenia following ES. Design: Retrospective observational cohort study. Methods: Patients with thrombocytopenia (defined as <150,000 platelets/µL) who underwent ES between May 2017 and December 2020 were identified at a tertiary care medical center. The incidence of immediate (intraprocedural oozing >5 min or requiring intervention) or delayed (clinical bleeding with associated hemoglobin drop within 14 days) post-ES bleeding was determined via manual chart review. Results: A total of 221 patients with a mean platelet count of 108,000 ± 13,000 platelets/µL underwent ERCP with ES. Immediate bleeding occurred in 11 (5%) patients with no significant drop in hemoglobin or transfusion requirement. Two patients (0.9%), both of whom were noted to have immediate bleeding, also developed delayed bleeding. Presence of malignancy was associated with an increased risk of bleeding (36.4% versus 11.4%, p = 0.037) while platelet count was not. Conclusion: In a cohort of patients with thrombocytopenia, rates of immediate and delayed bleeding are similar to previously reported AE rates of ES in the general patient population. Careful attention should be given to patients with a history of active malignancy as well as those who develop immediate bleeding as they appear to be at increased risk for bleeding complications.


Risk of bleeding in patients with low platelet counts after sphincterotomy during endoscopic retrograde cholangiopancreatography procedures The sphincter that controls the flow of bile into the small bowel is often cut for a variety of clinical indications (sphincterotomy) during a procedure called endoscopic retrograde cholangiopancreatography (ERCP). One of the complications of this maneuver is bleeding. The physiology of bleeding is complex, and the risk of bleeding cannot be well captured by a single condition or laboratory test. It was presumed that low platelet counts would increase a patient's risk of bleeding during a procedure, but emerging data suggests that many endoscopic procedures are safer than previously understood in these patients. However, there is limited data for sphincterotomy and ERCP. This study from a single, academic center evaluates the outcomes of all patients who underwent sphincterotomy with platelets that were below the normal threshold. Overall, the data shows that sphincterotomy appears to be as safe in patients with low platelets as the general population. Patients with active cancer may be at slightly higher risk for bleeding. Additional precautions may be needed in this group, however further studies are needed to confirm this finding.

20.
Dig Dis Sci ; 68(11): 4259-4265, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37665426

ABSTRACT

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) within 72 h is suggested for patients presenting with acute biliary pancreatitis (ABP) and biliary obstruction without cholangitis. This study aimed to identify if urgent ERCP (within 24 h) improved outcomes compared to early ERCP (24-72 h) in patients admitted with predicted mild ABP. METHODS: Patients admitted for predicted mild ABP defined as a bedside index of severity in acute pancreatitis score < 3 and underwent ERCP for biliary obstruction within 72 h of presentation during the study period were included. Patients with prior biliary sphincterotomy or surgically altered anatomy preventing conventional ERCP were excluded. The primary outcome was the development of moderately severe or severe pancreatitis based on the revised Atlanta classification. Secondary outcomes were the length of hospital stay, the need for ICU admission, and ERCP-related adverse events (AEs). RESULTS: Of the identified 166 patients, baseline characteristics were similar between both the groups except for the WBC count (9.4 vs. 8.3/µL; p < 0.044) and serum bilirubin level (3.0 vs. 1.6 mg/dL; p < 0.0039). Biliary cannulation rate and technical success were both high in the overall cohort (98.8%). Urgent ERCP was not associated with increased development of moderately severe pancreatitis (10.4% vs. 15.7%; p = 0.3115). The urgent ERCP group had a significantly shorter length of hospital stay [median 3 (IQR 2-3) vs. 3 days (IQR 3-4), p < 0.01]. CONCLUSION: Urgent ERCP did not impact the rate of developing more severe pancreatitis in patients with predicted mild ABP but was associated with a shorter length of hospital stay and a lower rate of hospital readmission.

SELECTION OF CITATIONS
SEARCH DETAIL
...