Int J Pediatr Otorhinolaryngol ; 100: 86-90, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28802393

ABSTRACT

INTRODUCTION: Unilateral vocal fold paresis may significantly impair the vocal quality and laryngeal competence of a child. Relatively little literature relates to injection medialisation laryngoplasty (IML) in children and previous reports have involved small numbers of heterogenous cases. METHODS: A retrospective review was conducted of paediatric patients managed by our multidisciplinary specialist voice clinic undergoing IML for unilateral vocal fold paresis. Cases of bilateral paresis, those characterised by vocal fold fixation, and patients without formal pre and post-operative voice evaluation were excluded. RESULTS: Eighteen IML procedures were performed in 12 children eligible for inclusion between 2005 and 2015. The average age at time of procedure was 12 years (range 9-15 years). Autologous fat was used in 5 procedures, succeeded by calcium hydroxylapatite (Radiesse® Voice) from 2011 (n = 13). A significant improvement in median GRBAS score components was observed after calcium hydroxylapatite injection in terms of grade (p = 0.008), breathiness (p = 0.002) and aesthenia (p = 0.016). A pre- and post-procedural Voice Handicap Index was self-completed by 6 patients receiving calcium hydroxylapatite injection; the median change in score was an improvement of 19 points (interquartile range 36.5). CONCLUSION: We describe the outcomes of a comparatively large paediatric series and have found IML using calcium hydroxylapatite to be a reliable technique associated with improved subjective outcome measures. Management of UVCP in the child is a challenge with particular investigative and interventional considerations. Further study supported by high quality subjective and, where possible, objective outcome measures, is required to better inform patient selection, timing of intervention and choice of injection material.


Subject(s)
Laryngoplasty/methods , Vocal Cord Paralysis/surgery , Vocal Cords/surgery , Adolescent , Ambulatory Care Facilities , Child , Female , Humans , Injections , Male , Retrospective Studies , Treatment Outcome , Voice Quality
2.
Anaesthesia ; 72(8): 1043-1044, 2017 08.
Article in English | MEDLINE | ID: mdl-28695591
3.
Br J Anaesth ; 96(5): 669-70; author reply 670, 2006 May.
Article in English | MEDLINE | ID: mdl-16600907
9.
Anaesthesia ; 49(6): 555-6, 1994 Jun.
Article in English | MEDLINE | ID: mdl-8017626
10.
Anaesthesia ; 48(12): 1075-8, 1993 Dec.
Article in English | MEDLINE | ID: mdl-8285330

ABSTRACT

Laryngeal mask airway cuff inflation pressures were measured when inflated with the same volume of gas firstly in free space and then in position in the pharynx. A large difference in these pressures was observed and this was related to pharyngeal mucosal perfusion pressure. This study shows that it may be easy to produce pressures on the pharyngeal mucosa in excess of the critical perfusion pressure and thus potentiate mucosal trauma. Furthermore, laryngeal mask cuff pressures were measured at intervals during anaesthesia and were found to rise by a significant amount if room air was used as the cuff inflating gas. This effect could, however, be reversed if inspired gas was used to inflate the mask cuff. We conclude that care must be taken when inflating the laryngeal mask cuff if postoperative morbidity is to be avoided and also that it may not be necessary to use as high a volume of inflating gas as has been recommended during spontaneous respiration.


Subject(s)
Laryngeal Masks , Pharynx/physiology , Adult , Anesthesia, Inhalation/instrumentation , Anesthesia, Intravenous , Humans , Mucous Membrane/physiology , Nitrous Oxide , Oxygen , Pressure , Time Factors
12.
Br J Anaesth ; 68(3): 313-5, 1992 Mar.
Article in English | MEDLINE | ID: mdl-1547058

ABSTRACT

The bleeding times of five volunteers were assessed individually by each of 12 observers. The reliability of the measurements obtained was examined by comparing statistically the variability between subjects and between observers. This variability was found to be similar for both groups. Consequently, we suggest that the bleeding time estimation is an unreliable test and should not be used in isolation without reference to the salient features of a history and examination, when determining if an individual patient is at risk of haematoma formation as a complication of regional anaesthetic techniques.


Subject(s)
Bleeding Time , Humans , Observer Variation
13.
Reg Anesth ; 16(4): 236-9, 1991.
Article in English | MEDLINE | ID: mdl-1911502

ABSTRACT

In 100 pregnant women, identification of the epidural space was performed by a modified drip method. A saline infusion was prepared, leaving the distal 40 cm of infusion tubing full of air, and then attached to the hub of a Tuohy needle. Accurate identification of the epidural space was accomplished in less than one minute in 95% of cases. There were no unintentional dural punctures. This technique has advantages over the hanging drop and the manual loss of resistance techniques.


Subject(s)
Anesthesia, Epidural/methods , Anesthesia, Obstetrical/methods , Female , Humans , Pregnancy
14.
Anaesthesia ; 46(7): 573-5, 1991 Jul.
Article in English | MEDLINE | ID: mdl-1862900

ABSTRACT

Continuous epidural analgesia may be complicated by intravascular or subarachnoid injection of local analgesic, with disastrous consequences. One of the techniques described to prevent these complications is the aspiration test. It is the current standard of practice to employ a micropore bacterial filter for epidural infusions. We present an in vitro study of nine commercially available bacterial filters to determine whether or not the aspiration test could be reliably performed through them. Eight of the nine filters (except the Perifix, Braun) were found to be unreliable if air and liquid were both present in the system (air lock). The role of the aspiration test and the use of micropore filters in epidural analgesia are discussed, as are the implications and possible solutions in practice of this cause of failure of the test.


Subject(s)
Analgesia, Epidural/instrumentation , Micropore Filters , Analgesia, Epidural/methods , Bacteria/isolation & purification , Bupivacaine/administration & dosage , Equipment Contamination/prevention & control , Humans
16.
Br J Anaesth ; 61(3): 350-4, 1988 Sep.
Article in English | MEDLINE | ID: mdl-3179155

ABSTRACT

A mother with the Klippel-Feil syndrome, congenital hydrocephalus and increased intracranial pressure presented for delivery by Caesarean section at 33 weeks because of pre-eclampsia. Anaesthetic management comprised awake intubation using the fibreoptic bronchoscope, followed by induction and maintenance of general anaesthesia for the delivery of a live male infant. This case report describes the problems arising under these circumstances and the relative merits of different anaesthetic techniques.


Subject(s)
Anesthesia, General , Anesthesia, Obstetrical , Cesarean Section , Hydrocephalus/complications , Klippel-Feil Syndrome/complications , Pre-Eclampsia/complications , Adult , Female , Humans , Infant, Newborn , Male , Pregnancy
17.
Br J Anaesth ; 61(3): 250-4, 1988 Sep.
Article in English | MEDLINE | ID: mdl-3140860

ABSTRACT

The relationship between maternal FIO2 and umbilical venous PO2, PCO2, pH and neonatal Apgar and TSR (time to sustained respiration) scores was studied in 35 patients undergoing Caesarean section under general anaesthesia. Patients were allocated randomly to breathe an FIO2 of either 0.5 or 0.33. Umbilical venous blood was collected at the time of delivery, and TSR and 1- and 5-min Apgar scores recorded. Mean values for umbilical venous blood were: PO2 3.9 kPa and 3.7 kPa; PCO2 6.2 kPa and 6.2 kPa; pH 7.30 and 7.31 (50% and 33% groups, respectively (P greater than 0.05]. No differences were found between groups for 1- or 5-min Apgar scores or TSR values. It is concluded that no difference in fetal outcome or acid-base status can be detected when maternal FIO2 is decreased from 0.5 to 0.33, and that the use of 33% oxygen in 66% nitrous oxide appears to be safe for neonates who have not suffered fetal distress before delivery.


Subject(s)
Anesthesia, General , Anesthesia, Obstetrical , Cesarean Section , Infant, Newborn/physiology , Nitrous Oxide/administration & dosage , Oxygen/administration & dosage , Apgar Score , Carbon Dioxide/blood , Female , Fetal Blood/analysis , Humans , Oxygen/blood , Pregnancy , Respiration
18.
Br J Anaesth ; 59(11): 1381-91, 1987 Nov.
Article in English | MEDLINE | ID: mdl-3689612

ABSTRACT

Twenty-six patients manifesting severe pregnancy-induced (PIH) or pregnancy-aggravated (PAH) hypertension who presented for emergency Caesarean section under general anaesthesia were studied. All patients came from a previously identified high risk group--namely greater than 25 yr, multiparous and with diastolic arterial pressures sustained at greater than 120 mm Hg. Our standard accelerated induction technique for the management of severely hypertensive mothers was modified to include the use of fentanyl and droperidol before induction. This modification of the induction sequence produced a clinically significant amelioration of the reflex sympathetic hypertensive response to laryngoscopy and intubation in most mothers receiving antihypertensive therapy, without apparent deleterious effect in the immediate postoperative period to those neonates unaffected by intrauterine asphyxia.


Subject(s)
Adjuvants, Anesthesia , Anesthesia, General , Anesthesia, Obstetrical , Droperidol , Fentanyl , Hypertension , Pregnancy Complications, Cardiovascular , Adult , Apgar Score , Blood Pressure/drug effects , Cesarean Section , Droperidol/pharmacology , Emergencies , Female , Fentanyl/pharmacology , Humans , Hypertension/physiopathology , Infant, Newborn , Middle Aged , Pregnancy , Pregnancy Complications, Cardiovascular/physiopathology
19.
Anesth Analg ; 66(11): 1165-8, 1987 Nov.
Article in English | MEDLINE | ID: mdl-3662061

ABSTRACT

Sixty healthy mothers undergoing elective cesarean section received at random either midazolam 0.2 mg/kg or thiopental 3.5 mg/kg with succinylcholine 1 mg/kg for rapid sequence intravenous anesthetic induction. Maintenance of anesthesia was identical in all patients: 50:50 N2O in oxygen, halothane 0.5% and pancuronium 0.05 mg/kg. Hemodynamic responses were similar, as were the biochemical status of mothers and infants, and maternal to fetal blood gas/acid base gradients. Correlation between maternal arterial and fetal (umbilical venous/arterial) pH, PCO2 and base excess values were statistically better with midazolam. However, 1-min Apgar minus color (A-C) scores less than 5/8 (representing "severe" neonatal depression) were recorded in five infants after midazolam, three of whom required tracheal intubation, and one whose mother was given thiopental. This difference reached statistical significance (P less than 0.05). It is concluded that midazolam is less suitable than thiopental for anesthetic induction in patients undergoing cesarean section.


Subject(s)
Anesthesia, Obstetrical , Cesarean Section , Midazolam , Blood Gas Analysis , Female , Fetal Blood/analysis , Humans , Pregnancy , Random Allocation , Thiopental
20.
Br J Anaesth ; 59(3): 315-8, 1987 Mar.
Article in English | MEDLINE | ID: mdl-3828180

ABSTRACT

An investigation was carried out into the relationship between the inflation pressures of normally compliant lungs and the airways pressure necessary to produce the insufflation of gas to the stomach. This relationship was examined during manual ventilation with a mask, using a rapid sequence induction technique. In the absence of cricoid pressure the lungs of all the patients could be ventilated "gently" satisfactorily by hand without gas entering the stomach. In only half of the patients could gas be redirected to the stomach when maximal inflation pressures were generated. It was not possible to cause gas to enter the stomach in any patient with a patent airway when cricoid pressure was applied.


Subject(s)
Anesthesia, Inhalation , Lung/physiology , Respiration, Artificial , Stomach/physiology , Adolescent , Adult , Aged , Cricoid Cartilage/physiology , Gases , Humans , Middle Aged , Pressure , Time Factors
SELECTION OF CITATIONS