Transl Vis Sci Technol ; 11(8): 6, 2022 08 01.
Article in English | MEDLINE | ID: mdl-35930278

ABSTRACT

Purpose: The purpose of this study was to assess the accuracy, repeatability, and performance limits of in vivo Mirau ultrahigh axial resolution (UHR) line field spectral domain (LF-SD) optical coherence tomography (OCT) for the measurement of Bowman's and epithelial thickness, and to provide a reference range of these values for healthy corneas. Methods: Volunteers with no history and evidence of corneal disease were included in this study. An in vivo graph search image segmentation of the central cornea was obtained at the normal interface vector orientation. The Mirau-UHR-LF-SD-OCT system used has an axial resolution down to 2.4 µm in air (1.7 µm in tissue), with an A-scan speed of 204.8 kHz and a signal to noise ratio (sensitivity) of 69 (83) dB. Results: Nine volunteers were included, one of whom wore contact lenses. The repeatability of mean Bowman's and epithelial thicknesses were 0.3 and 1.0 µm, respectively. The measured 95% population range for healthy in vivo thickness was 13.7 to 19.6 µm for the Bowman's layer, and 41.9 to 61.8 µm for the epithelial layer. Conclusions: The measured thicknesses of Bowman's layer and the corneal epithelium using the Mirau-UHR-LF-SD-OCT were both accurate, with the range for healthy in vivo thicknesses matching prior confocal and OCT systems of varying axial resolutions, and repeatable, equaling the best value prior reported. Translational Relevance: T1. Development of a commercially viable clinical UHR OCT technology, enabling accurate measurement and interpretation of Bowman's and epithelial layer thickness in clinical practice.


Subject(s)
Contact Lenses , Epithelium, Corneal , Bowman Membrane/diagnostic imaging , Cornea/diagnostic imaging , Epithelium, Corneal/diagnostic imaging , Humans , Tomography, Optical Coherence/methods
2.
Opt Express ; 28(26): 39660-39676, 2020 Dec 21.
Article in English | MEDLINE | ID: mdl-33379511

ABSTRACT

For any single anterior chamber cross-sectional (tomographic) imaging method, there is a practical compromise between image size and image resolution. In order to obtain large field-of-view cross-sectional images of the whole anterior chamber and high-resolution cross-sectional images of the fine corneal layers, measurements by multiple devices are currently required. This paper presents a novel raster scanning tomographic imaging device that acquires simultaneous large field-of-view Scheimpflug (12.5 mm image depth, 50 µm axial resolution in air) and high-resolution spectral domain optical coherence tomography (SD-OCT) (2 mm image depth, 3.7µm axial resolution in air) using the same illuminating photons. For the novel raster scanning 3D Scheimpflug imaging, a tunable lens system together with numerical methods for correcting refraction distortion were used. To demonstrate the capability of simultaneous measurement of both fine corneal layers and whole anterior chambers topology, ex vivo measurements on 12 porcine and 12 bovine eyes were carried out. There is a reasonable agreement in the overall central corneal thicknesses (CCT) obtained from the simultaneous SD-OCT and Scheimpflug measurements. In addition, because the same infrared light beam was used to illuminate the sample, both OCT and Scheimpflug images were taken at the exact same location of a sample simultaneously in a single measurement. This provides a unique method for measuring both the thickness and the refractive index of a sample.

3.
Opt Express ; 27(10): 13951-13964, 2019 May 13.
Article in English | MEDLINE | ID: mdl-31163852

ABSTRACT

In the laundry industry, colorimetry is a common way to evaluate the stain removal efficiency of detergents and cleaning products. For ease of visualization, the soiling agent is treated with a dye before measurement. However, it effectively measures the dye removal rather than stain removal, and it cannot provide depth-resolved information of the sample. In this study, we show that full-field (FF) optical coherence tomography (OCT) technique is capable of measuring the cleaning effect on cotton fabric by imaging the sub-surface features of fabric samples. We used a broadband light-emitting diode (LED) source to power the FF-OCT system that achieves the resolution of 1 µm axially and 1.6 µm laterally. This allows the micron-sized cotton fibres/fibrils at different depth positions to be resolved. The clean, the soiled, and the washed samples can be differentiated from their cross-sectional images using OCT, where the cleaning effect can be correlated with the sub-surface fibre volume. The experimental results of the proposed method were found to be in good agreement with those of the standard colorimetry method. The proposed technique therefore offers an alternative way for measuring the stain removal from fabric substrate to assess the effectiveness of laundry detergent products.

4.
Sci Rep ; 9(1): 6321, 2019 04 19.
Article in English | MEDLINE | ID: mdl-31004101

ABSTRACT

There has been a lot of interest in accurately characterising corneal biomechanical properties under intraocular pressure (IOP) to help better understand ocular pathologies that are associated with elevated IOP. This study investigates the novel use of Line-Field Optical Coherence Tomography (LF-OCT) as an elastographic tool for accurately measuring mechanical properties of porcine corneas based on volumetric deformation following varying IOPs. A custom-built LF-OCT was used to measure geometrical and corneal surface displacement changes in porcine corneas under a range of IOPs, from 0-60 mmHg. Corneal thickness, elastic properties and hysteresis were calculated as a function of pressure. In addition, the effects of hydration were explored. We found that the elastic modulus increased in a linear fashion with IOP. Corneal thickness was found to reduce with IOP, decreasing 14% from 0 to 60 mmHg. Prolonged hydration in phosphate buffered saline (PBS) was found to significantly increase the elastic modulus and corneal hysteresis. Our study demonstrates that LF-OCT can be used to accurately measure the elastic properties based on volumetric deformation following physiological pressures. Furthermore, we show that prolonged hydration in PBS has a significant effect on the measured corneal properties.


Subject(s)
Cornea , Intraocular Pressure , Tomography, Optical Coherence , Animals , Cornea/diagnostic imaging , Cornea/physiopathology , Elastic Modulus , Swine , Tonometry, Ocular
5.
Invest Ophthalmol Vis Sci ; 59(3): 1263-1269, 2018 03 01.
Article in English | MEDLINE | ID: mdl-29625447

ABSTRACT

Purpose: The purpose of this study was to compare optical coherence tomography angiography (OCTA) and indocyanine green angiography (ICGA) for the assessment of corneal neovascularization (CoNV). Methods: Patients with CoNV extending at least 3 mm into the cornea were included. All patients underwent corneal imaging at the same visit. Images were recorded using the AngioVue OCTA system (Optovue, Inc.) with the long corneal adaptor module (CAM-L). ICGA images were recorded with fluorescent filters using the Heidelberg system (HRA2 Scanning Laser Ophthalmoscope; Heidelberg Engineering). Images were graded for quality by two independent observers. Vessel parameters: area, number, diameter, branch and end points, and tortuosity, were compared between devices. Bland-Altman plots were used to assess differences between parameters. Results: Fifteen patients with CoNV predominantly associated with microbial keratitis were included. Mean subjective image quality score was better for ICGA (3.3 ± 0.9) than for OCTA (2.1 ± 1.2, P = 0.002), with almost perfect interobserver agreement for ICGA images (κ = 0.83) and substantial agreement for OCTA images (κ = 0.69). Agreement of grading of all investigated vessel parameters between ICGA and OCT images was slight to moderate, with significant differences found for vessel diameter (-8.98 µm, P = 0.01, 95% limits of agreement [LOA]: -15.89 to -2.07), number of branch (25.93, P = 0.09, 95% LOA: -4.31 to 56.17), and terminal points (49, P = 0.05, 95% LOA: 0.78 to 97.22). Conclusion: Compared with ICGA, current OCTA systems are less precise in capturing small vessels in CoNV complexes, and validation studies are needed for OCTA segmentation software. OCTA, however, complements ICGA by providing evidence of red blood cell flow, which together with depth information, may be helpful when planning treatment of CoNV.


Subject(s)
Corneal Neovascularization/diagnostic imaging , Fluorescein Angiography/methods , Optical Imaging/methods , Tomography, Optical Coherence/methods , Adult , Aged , Coloring Agents/administration & dosage , Cornea/blood supply , Cornea/pathology , Female , Humans , Indocyanine Green/administration & dosage , Male , Middle Aged
6.
Opt Express ; 25(16): 18614-18628, 2017 Aug 07.
Article in English | MEDLINE | ID: mdl-29041059

ABSTRACT

Automotive coating systems are designed to protect vehicle bodies from corrosion and enhance their aesthetic value. The number, size and orientation of small metallic flakes in the base coat of the paint has a significant effect on the appearance of automotive bodies. It is important for quality assurance (QA) to be able to measure the properties of these small flakes, which are approximately 10µm in radius, yet current QA techniques are limited to measuring layer thickness. We design and develop a time-domain (TD) full-field (FF) optical coherence tomography (OCT) system to scan automotive panels volumetrically, non-destructively and without contact. We develop and integrate a segmentation method to automatically distinguish flakes and allow measurement of their properties. We test our integrated system on nine sections of five panels and demonstrate that this integrated approach can characterise small flakes in automotive coating systems in 3D, calculating the number, size and orientation accurately and consistently. This has the potential to significantly impact QA testing in the automotive industry.

7.
Biomed Opt Express ; 8(12): 5579-5593, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-29296489

ABSTRACT

Optical coherence tomography (OCT) can monitor human donor corneas non-invasively during the de-swelling process following storage for corneal transplantation, but currently only resultant thickness as a function of time is extracted. To visualize and quantify the mechanism of de-swelling, we present a method exploiting the nanometer sensitivity of the Fourier phase in OCT data to image deformation velocities. The technique was demonstrated by non-invasively showing during de-swelling that osmotic flow through an intact epithelium is negligible and removing the endothelium approximately doubled the initial flow at that interface. The increased functional data further enabled the validation of a mathematical model of the cornea. Included is an efficient method of measuring high temporal resolution (1 minute demonstrated) corneal thickness, using automated collection and semi-automated graph search segmentation. These methods expand OCT capabilities to measure volume change processes for tissues and materials.

8.
Opt Express ; 24(11): 12395-405, 2016 May 30.
Article in English | MEDLINE | ID: mdl-27410154

ABSTRACT

We report the development of a Spectral Domain Line Field Optical Coherence Tomography (LF-OCT) system, using a broad bandwidth and spatial coherent Super-Continuum (SC) source. With conventional quasi-Continuous Wave (CW) setup we achieve axial resolutions up to 2.1 µm in air and 3D volume imaging speeds up to 213 kA-Scan/s. Furthermore, we report the use of a single SC pulse, of 2 ns duration, to temporally gate an OCT B-Scan image of 70 A-Scans. This is the equivalent of 35 GA-Scans/s. We apply the CW setup for high resolution imaging of the fine structures of a human cornea sample ex-vivo. The single pulse setup is applied to imaging of a coated pharmaceutical tablet. The fixed pattern noise due to spectral noise is removed by subtracting the median magnitude A-Scan. We also demonstrate that the Fourier phase can be used to remove aberration caused artefacts.

9.
Appl Opt ; 55(13): 3695-700, 2016 May 01.
Article in English | MEDLINE | ID: mdl-27140390

ABSTRACT

We have demonstrated for the first time, to our knowledge, the use of optical coherence tomography (OCT) as an analytical tool for nondestructively characterizing the individual paint layer thickness of multiple layered automotive paints. A graph-based segmentation method was used for automatic analysis of the thickness distribution for the top layers of solid color paints. The thicknesses measured with OCT were in good agreement with the optical microscope and ultrasonic techniques that are the current standard in the automobile industry. Because of its high axial resolution (5.5 µm), the OCT technique was shown to be able to resolve the thickness of individual paint layers down to 11 µm. With its high lateral resolution (12.4 µm), the OCT system was also able to measure the cross-sectional area of the aluminum flakes in a metallic automotive paint. The range of values measured was 300-1850 µm2. In summary, the proposed OCT is a noncontact, high-resolution technique that has the potential for inclusion as part of the quality assurance process in automobile coating.

10.
Appl Opt ; 50(32): 6039-48, 2011 Nov 10.
Article in English | MEDLINE | ID: mdl-22083374

ABSTRACT

Optical coherence tomography (OCT) has mostly been used for high-speed volume imaging but its profilometry potentials have not been fully exploited. This paper demonstrates high precision (as good as ~50 nm) multi-interface profilometry using a Fourier domain OCT system without special antivibration devices. The precision is up to 2 orders of magnitude better than the depth resolution of the OCT. Detailed analysis of the precision achieved for different surfaces is presented. The multi-interface profiles are obtained as a by-product of the tomography data. OCT has the advantage in speed and sensitivity at detecting rough and internal interfaces versus conventional optical profilometry. An application of the technique to the dynamic monitoring of varnish drying on paintlike substrates is demonstrated, which provides a better understanding of the formation of surface roughness. The technique has potential benefits in the fields of art conservation, coatings technology, and soft matter physics.


Subject(s)
Image Enhancement/instrumentation , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Tomography, Optical Coherence/instrumentation , Tomography, Optical Coherence/methods , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity