Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Jt Comm J Qual Patient Saf ; 50(1): 6-15, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37481433

ABSTRACT

BACKGROUND: Maternal mortality in the United States is high, and women and birthing people of color experience higher rates of mortality and severe maternal morbidity (SMM). More than half of maternal deaths and cases of SMM are considered preventable. The research presented here investigated systems issues contributing to adverse outcomes and racial/ethnic disparities in maternal care using patient safety incident reports. METHODS: The authors reviewed incidents reported in the labor and delivery unit (L&D) and the antepartum and postpartum unit (A&P) of a large academic hospital in 2019 and 2020. Deliveries associated with a reported incident were described by race/ethnicity, age group, method of delivery, and several other process variables. Differences across racial/ethnic group were statistically evaluated. RESULTS: Almost two thirds (64.8%) of the 528 reports analyzed were reported in L&D, and 35.2% were reported in A&P. Non-Hispanic white (NHW) patients accounted for 43.9% of reported incidents, non-Hispanic Black (NHB) patients accounted for 43.2%, Hispanic patients accounted for 8.9%, and patients categorized as "other" accounted for 4.0%. NHB patients were disproportionally represented in the incident reports, as they accounted for only 36.5% of the underlying birthing population. The odds ratio (OR) demonstrated a higher risk of a reported adverse incident for NHB patients; however, adjustment for cesarean section attenuated the association (OR 1.25, 95% confidence interval 1.01-1.54). CONCLUSION: Greater integration of patient safety and health equity efforts in hospitals are needed to promptly identify and alleviate racial and ethnic disparities in maternal health outcomes. Although additional systems analysis is necessary, the authors offer recommendations to support safer, more equitable maternal care.


Subject(s)
Cesarean Section , Healthcare Disparities , Patient Safety , Female , Humans , Pregnancy , Black or African American , Ethnicity , United States , White , Hispanic or Latino , Racial Groups , Maternal Health Services
2.
Hum Factors ; : 187208211068946, 2022 Mar 05.
Article in English | MEDLINE | ID: mdl-35253508

ABSTRACT

OBJECTIVE: Using the example of robotic-assisted surgery (RAS), we explore the methodological and practical challenges of technology integration in surgery, provide examples of evidence-based improvements, and discuss the importance of systems engineering and clinical human factors research and practice. BACKGROUND: New operating room technologies offer potential benefits for patients and staff, yet also present challenges for physical, procedural, team, and organizational integration. Historically, RAS implementation has focused on establishing the technical skills of the surgeon on the console, and has not systematically addressed the new skills required for other team members, the use of the workspace, or the organizational changes. RESULTS: Human factors studies of robotic surgery have demonstrated not just the effects of these hidden complexities on people, teams, processes, and proximal outcomes, but also have been able to analyze and explain in detail why they happen and offer methods to address them. We review studies on workload, communication, workflow, workspace, and coordination in robotic surgery, and then discuss the potential for improvement that these studies suggest within the wider healthcare system. CONCLUSION: There is a growing need to understand and develop approaches to safety and quality improvement through human-systems integration at the frontline of care.Precis: The introduction of robotic surgery has exposed under-acknowledged complexities of introducing complex technology into operating rooms. We explore the methodological and practical challenges, provide examples of evidence-based improvements, and discuss the implications for systems engineering and clinical human factors research and practice.

3.
Br J Anaesth ; 127(5): 729-744, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34452733

ABSTRACT

Non-operating room anaesthesia (NORA) describes anaesthesia delivered outside a traditional operating room (OR) setting. Non-operating room anaesthesia cases have increased significantly in the last 20 yr and are projected to account for half of all anaesthetics delivered in the next decade. In contrast to most other medication administration contexts, NORA is performed in high-volume fast-paced environments not optimised for anaesthesia care. These predisposing factors combined with increasing case volume, less provider experience, and higher-acuity patients increase the potential for preventable adverse events. Our narrative review examines morbidity and mortality in NORA settings compared with the OR and the systems factors impacting safety in NORA. A review of the literature from January 1, 1994 to March 5, 2021 was conducted using PubMed, CINAHL, Scopus, and ProQuest. After completing abstract screening and full-text review, 30 articles were selected for inclusion. These articles suggested higher rates of morbidity and mortality in NORA cases compared with OR cases. This included a higher proportion of death claims and complications attributable to inadequate oxygenation, and a higher likelihood that adverse events are preventable. Despite relatively few attempts to quantify safety concerns, it was possible to find a range of systems safety concerns repeated across multiple studies, including insufficient lighting, noise, cramped workspace, and restricted access to patients. Old and unfamiliar equipment, lack of team familiarity, and limited preoperative evaluation are also commonly noted challenges. Applying a systems view of safety, it is possible to suggest a range of methods to improve NORA safety and performance.


Subject(s)
Anesthesia/methods , Anesthetics/administration & dosage , Oxygen/metabolism , Anesthesia/adverse effects , Anesthesia/mortality , Anesthetics/adverse effects , Equipment Design , Humans
4.
Case Rep Vet Med ; 2020: 6543037, 2020.
Article in English | MEDLINE | ID: mdl-32095313

ABSTRACT

A six-year-old multiparous Angus cow was presented for dystocia. Vaginal and rectal examinations revealed an approximately 360° counterclockwise uterine torsion. The torsion was corrected by rolling the cow counterclockwise (three episodes) with the aid of a plank coupled with manual detorsion via the vagina. The placement of obstetric chains followed by manual traction ultimately delivered a stillborn male calf with evidence of vertebral aplasia, arthrogryposis, and abdominal organ herniation. Patient history and subsequent parentage verification revealed that the calf was the result of a consanguineous (mother to son) mating. Tissue samples from the affected calf and blood samples from the dam, sire, and ten half siblings were collected for genetic testing and parentage verification. Necropsy, radiographic, and computed tomography examinations all supported a diagnosis of perosomus elumbis. Perosomus elumbis is a congenital abnormality of unknown origin(s), and this is the first report of a case associated with a consanguineous mating.

SELECTION OF CITATIONS
SEARCH DETAIL
...