Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Eur J Radiol ; 147: 110145, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35007983

ABSTRACT

PURPOSE: To investigate the effects of a rectal preparation regimen, that consisted of a rectal cleansing enema and an endorectal gel filling protocol, on prostate imaging quality (PI-QUAL). METHODS: Multiparametric MRI (mpMRI) was performed in 150 consecutive patients divided into two groups of 75 patients. One group received a rectal preparation with a cleansing enema and endorectal gel filling (median age 65.3 years, median PSA level 6 ng/ml). The other patient group did not receive such a preparation (median age 64 years, median PSA level 6 ng/ml). Two uroradiologists independently rated general image quality and lesion visibility on diffusion-weighted imaging (DWI), T2-weighted (T2w), and dynamic contrast-enhanced (DCE) images using a five-point ordinal scale. In addition, two uroradiologists assigned PI-QUAL scores, using the dedicated scoring sheet. Data sets were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/ area under the curve (AUC) analysis. RESULTS: VGC revealed significantly better general image quality for DWI (AUC R1 0.708 (0.628-0.779 CI, p < 0.001; AUC R2 0.687 (0.606-0.760 CI, p < 0.001) and lesion visibility for both readers (AUC R1 0.729 (0.607-0.831 CI, p < 0.001); AUC R2 0.714 (0.590-0.818CI, p < 0.001) in the preparation group. For T2w imaging, rectal preparation resulted in significantly better lesion visibility for both readers (R1 0.663 (0.537-0.774 CI, p = 0.014; R2 0.663 (0.537-0.774 CI, p = 0.014)). Averaged PI-QUAL scores were significantly improved with rectal preparation (AUC R3/R4 0.667, CI 0.581-0.754, p < 0.001). CONCLUSION: Rectal preparation significantly improved prostate imaging quality (PI-QUAL) and lesion visibility. Hence, a rectal preparation regimen consisting of a rectal cleansing enema and an endorectal gel filling could be considered.


Subject(s)
Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms , Aged , Diffusion Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Prostate , Retrospective Studies
3.
Invest Radiol ; 54(5): 257-264, 2019 05.
Article in English | MEDLINE | ID: mdl-30632985

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate breast multiparametric ultrasound (mpUS) and its potential to reduce unnecessary breast biopsies with 1, 2, or 3 additional quantitative parameters (Doppler, elastography, and contrast-enhanced ultrasound [CEUS]) to B-mode and investigate possible variations with different reader experience. MATERIALS AND METHODS: This prospective study included 124 women (age range, 18-82 years; mean, 52 years), each with 1 new breast lesion, scheduled for ultrasound-guided biopsy between October 2015 and September 2016. Each lesion was examined with B-mode, elastography (Virtual Touch IQ [VTIQ]), Doppler, and CEUS, and different quantitative parameters were recorded for each modality. Four readers (2 experienced breast radiologists and 2 in-training) independently evaluated B-mode images of each lesion and assigned a BI-RADS (Breast Imaging Reporting and Data System) score. Using the area under the receiver operating characteristic curve (AUC), the most accurate quantitative parameter for each modality was chosen. These were then combined with the BI-RADS scores of all readers. Descriptive statistics and AUC were used to evaluate the diagnostic performance of mpUS. RESULTS: Sixty-five lesions were malignant. MpUS with B-mode and 2 additional quantitative parameters (VTIQ and CEUS or Doppler) showed the highest diagnostic performance for all readers (averaged AUCs, 0.812-0.789 respectively vs 0.683 for B-mode, P = 0.0001). Both combinations significantly reduced the number of false-positive findings up to 46.9% (P < 0.0001). CONCLUSIONS: Quantitative mpUS with 2 different triple assessment modalities (B-mode, VTIQ elastography, CEUS, or Doppler) shows the best diagnostic performance for breast cancer diagnosis and leads to a significant reduction of false-positive biopsy recommendations, for both experienced and inexperienced readers.


Subject(s)
Breast Neoplasms/diagnostic imaging , Contrast Media , Image Enhancement/methods , Ultrasonography, Mammary/methods , Adolescent , Adult , Aged , Aged, 80 and over , Breast/diagnostic imaging , Breast Neoplasms/pathology , Diagnosis, Differential , Elasticity Imaging Techniques/methods , Evaluation Studies as Topic , Female , Humans , Middle Aged , Prospective Studies , ROC Curve , Reproducibility of Results , Sensitivity and Specificity , Young Adult
4.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1552-1561, 2019 May.
Article in English | MEDLINE | ID: mdl-29881885

ABSTRACT

PURPOSE: To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. METHODS: Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. RESULTS: The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. CONCLUSIONS: Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.


Subject(s)
Arthroplasty, Replacement, Knee , Artifacts , Metals/chemistry , Radiographic Image Interpretation, Computer-Assisted , Titanium/chemistry , Ceramics/chemistry , Chromium Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Computer Simulation , Humans , Phantoms, Imaging , Prostheses and Implants , Reproducibility of Results , Tomography, X-Ray Computed
5.
Eur Radiol ; 28(4): 1634-1641, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29134351

ABSTRACT

OBJECTIVES: To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. METHODS: This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. RESULTS: Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). CONCLUSIONS: Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. KEY POINTS: • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.


Subject(s)
Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Prostate/pathology , Prostatic Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Area Under Curve , Humans , Male , Middle Aged , Prospective Studies , ROC Curve
6.
Acad Radiol ; 24(12): 1491-1500, 2017 12.
Article in English | MEDLINE | ID: mdl-28756085

ABSTRACT

RATIONALE AND OBJECTIVES: This study aimed to investigate the potential of contrast-enhanced magnetic resonance imaging features to differentiate between mass-forming intrahepatic cholangiocellular carcinoma (ICC) and hepatocellular carcinoma (HCC) in cirrhotic livers. MATERIALS AND METHODS: This study, performed between 2001 and 2013, included 64 baseline magnetic resonance imaging examinations with pathohistologically proven liver cirrhosis, presenting with either ICC (n = 32) or HCC (n = 32) tumors. To distinguish ICC form HCC tumors, 20 qualitative single-lesion descriptors were evaluated by two readers, in consensus, and statistically classified using the chi-square automatic interaction detection (CHAID) methodology. Diagnostic performance was assessed by a receiver operating characteristic analysis. RESULTS: The CHAID algorithm identified three independent categorical lesion descriptors, including (1) liver capsular retraction; (2) progressive or persistent enhancement pattern or wash-out on the T1-weighted delayed phase; and (3) signal intensity appearance on T2-weighted images that could help to reliably differentiate ICC from HCC, which resulted in an AUC of 0.807, and a sensitivity and specificity of 68.8 and 90.6 (95% confidence interval 75.0-98.0), respectively. CONCLUSIONS: The proposed CHAID algorithm provides a simple and robust step-by-step classification tool for a reliable and solid differentiation between ICC and HCC tumors in cirrhotic livers.


Subject(s)
Bile Duct Neoplasms/diagnostic imaging , Bile Ducts, Intrahepatic/diagnostic imaging , Carcinoma, Hepatocellular/diagnostic imaging , Cholangiocarcinoma/diagnostic imaging , Contrast Media/administration & dosage , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Adult , Aged , Aged, 80 and over , Case-Control Studies , Humans , Liver Cirrhosis/diagnostic imaging , Middle Aged , Retrospective Studies , Sensitivity and Specificity
7.
Eur Radiol ; 25(7): 1865-74, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25680714

ABSTRACT

OBJECTIVE: To assess a radiologist's detection rate of rib fractures in trauma CT when reading curved planar reformats (CPRs) of the ribs compared to reading standard MPRs. METHODS: Two hundred and twenty trauma CTs (146 males, 74 females) were retrospectively subjected to a software algorithm to generate CPRs of the ribs. Patients were split into two equal groups. Sixteen patients were excluded due to insufficient segmentation, leaving 107 patients in group A and 97 patients in group B. Two radiologists independently evaluated group A using CPRs and group B using standard MPRs. Two different radiologists reviewed both groups with the inverse methods setting. Results were compared to a standard of reference created by two senior radiologists. RESULTS: The reference standard identified 361 rib fractures in 61 patients. Reading CPRs showed a significantly higher overall sensitivity (P < 0.001) for fracture detection than reading standard MPRs, with 80.9% (584/722) and 71.5% (516/722), respectively. Mean reading time was significantly shorter for CPRs (31.3 s) compared to standard MPRs (60.7 s; P < 0.001). CONCLUSION: Using CPRs for the detection of rib fractures accelerates the reading of trauma patient chest CTs, while offering an increased overall sensitivity compared to conventional standard MPRs. KEY POINTS: • In major blunt trauma, rib fractures are diagnosed with Computed Tomography. • Image processing can unfold all ribs into a single plane. • Unfolded ribs can be read twice as fast as axial images. • Unfolding the ribs allows a more accurate diagnosis of rib fractures.


Subject(s)
Rib Fractures/diagnostic imaging , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Algorithms , Child , Child, Preschool , Female , Humans , Image Processing, Computer-Assisted , Infant , Male , Middle Aged , Multiple Trauma/diagnostic imaging , Observer Variation , Retrospective Studies , Ribs/diagnostic imaging , Ribs/injuries , Sensitivity and Specificity , Thoracic Injuries/diagnostic imaging , Wounds, Nonpenetrating/diagnostic imaging , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...