Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Pregnancy Childbirth ; 23(1): 788, 2023 Nov 11.
Article in English | MEDLINE | ID: mdl-37951881

ABSTRACT

BACKGROUND: Pregnancy has major effects that make hematology parameters outside of normal reference ranges. Therefore, we conducted this study to establish reference intervals for Vietnamese pregnant women. METHODS: From June 2023 to Augst 2023, blood samples from 879 eligible pregnant women were run on DxH 900 hematology analyzer and ACL TOP 550 coagulation analyzer. The tested parameters are prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (FIB), white blood cell (WBC) and its differentials (neutrophils, lymphocytes, monocytes, eosinophils and basophils), red blood cell (RBC), hemoglobin (HGB), hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), RBC distribution width (RDW), RBC distribution width standard deviation (RDW-SD), platelet count (PLT), mean platelet volume (MPV). A non-parametric method was used to establish the 2.5th and 97.5th percentile reference intervals. RESULTS: PT, APTT decrease but fibrinogen increases during pregnancy. Physiological adaptations of pregnancy result in a decrease in RBC count, but an increase in WBC count and no changes in platelet count. The reference intervals for PT (seconds), APTT (seconds), fibrinogen (mg/dL), in the first trimester were 10.30-12.88, 25.40-35.46, 280.28-559.00, in the second trimester were 9.80-11.66, 24.05-33.23, 347.75-593.35, in the third trimester were 9.60-11.40, 23.40-31.80, 330.28-628.56, respectively. The reference intervals for main hematology parameters which are WBC (× 109/L), RBC (× 1012/L), HGB (g/dL), HCT (%), PLT (× 109/L) in the first trimester were 6.33-15.24, 3.73-5.32, 10.33-13.95, 32.22-42.29, 169.66-413.88, in the second trimester were 6.99-15.55, 3.33-4.98, 9.71-13.17, 30.26-40.07, 172.34-372.19, in the third trimester were 6.22-14.14, 3.54-4.98, 9.80-13.97, 31.11-42.70, 151.30-417.14, respectively. CONCLUSIONS: Most established referenced intervals from each trimester differ from other trimesters. These trimester-specific reference ranges for Vietnamese pregnant women will aid clinicians in entepreting parameters and help other laboratories adopt these ranges after validating. TRIAL REGISTRATION: This study is registered at www. CLINICALTRIALS: gov as NCT05929326.


Subject(s)
Pregnant Women , Southeast Asian People , Female , Pregnancy , Humans , Blood Cell Count , Blood Coagulation Tests , Hemoglobins/analysis , Fibrinogen , Reference Values
2.
Hematol Rep ; 14(2): 73-84, 2022 Mar 25.
Article in English | MEDLINE | ID: mdl-35466176

ABSTRACT

Introduction: The haematology external quality assessment (EQA) scheme is the most commonly used service of quality assurance. The provision of complete blood count (CBC) materials must meet the quality requirements at a reasonable cost. These requirements are the most significant challenges for EQA organisers in Vietnam. This study's objective was to evaluate the homogeneity, long-term stability, and peer-group performance of 10-parameter stabilised CBC EQA samples. Methods: The CBC EQA material was prepared using the following steps, including (1) adjusting levels of stabilised erythrocyte, leukocyte, and platelet samples, (2) mixing those cells into batches at three levels, and (3) dispensing and storing them at 2-6 °C. A set of 10 and 30 specimens were randomly chosen from each batch to study the homogeneity and long-term stability following ISO 13528:2015. In total, 166 samples at two levels were randomly distributed to 40 participants, which reported 83 automatic cell counters among six automated analyser models in the CBC EQA program. Results: The 10-parameter stabilised CBC EQA materials at three levels became homogeneous and stable in 12 weeks when preserved at 2-6 °C. Meanwhile, for five parameters (RBC, Hb, MCH, MCV, and MPV), this process was prolonged for up to 16 weeks in stock condition. In terms of peer-group performance, the CV (%) values increased at the low concentration for almost all parameters, especially in platelet counts. Conclusions: The stabilised CBC EQA samples prepared using the partial fixation method with aldehyde and gutaraldehyde in this study meet the ISO 13528:2015 requirements of homogeneity and long-term stability for the CBC EQA scheme. Analytical performance evaluation should categorise participant methods into peer groups.

SELECTION OF CITATIONS
SEARCH DETAIL
...