Diagn Microbiol Infect Dis ; 89(1): 29-34, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28669680

ABSTRACT

We evaluated the utility of Architect core antigen assay® Abbott Diagnostics (HCVAg) for monitoring patients with HCV infection and compared to HCV-RNA quantification (Cobas Ampliprep TaqMan-Roche Diagnostics). Samples from 262 patients were studied. Mean baseline HCV RNA and HCVAg levels were similar for responders (6.2 log IU/mL and 3.4 log fmol/L) and non-responders (6.1 log IU/mL and 3.2 log fmol/L), respectively. Only 10 patients failed to achieve SVR12 and all were detected by both assays. To evaluate HCVAg quantification as a tool for the detection of failure to DAAs, we performed a retrospective study of 132 non-responder patients. Mean HCV RNA and HCVAg levels at the time of detection of therapeutic failure were 5.88±0.97 log IU/mL and 3.19±0.79 log fmol/L, respectively. HCVAg (>3 fmol/L) was detected in 130/132 patients (98.5%). HCVAg assay was useful for patient selection and for evaluating virological response to DAAs in the real world.