Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 58(1): 31-37, ene.-feb. 2014. ilus, tab
Article in Spanish | IBECS | ID: ibc-118588

ABSTRACT

Introducción y objetivo. Las fracturas de húmero distal en ancianos asocian mala calidad ósea y gran conminución, lo que teóricamente dificultaría la síntesis de las mismas. Nuestro objetivo es evaluar los resultados radiológicos y funcionales del tratamiento mediante reducción abierta y fijación interna de estas fracturas. Material y métodos. Estudio retrospectivo entre los años 2005-2010 de 26 pacientes tratados mediante reducción abierta y fijación interna. Seguimiento medio de 42 meses. Al finalizar el mismo se realizó una valoración radiográfica (Knirk and Jupiter scale) y funcional mediante las escalas Mayo Elbow Performance Score y Quick-Disabilities of the Arm, Shoulder and Hand Score. La edad media fue de 76,8 años (65-89) siendo el 83% mujeres. Se encontraron 16 pacientes con fractura tipo C y 8 tipo A (según la AO). Todos fueron tratados mediante abordaje posterior. Resultados. La flexión media fue de 118,86° con un déficit de extensión medio de 25°. El 79,1% de los pacientes presentaban un grado 0-1 de artrosis. La media obtenida en las escalas funcionales fue: Quick-Disabilities of the Arm, Shoulder and Hand Score: 19,87; Mayo Elbow Performance Score: 85. Encontramos 2 casos de seudoartrosis: una de húmero distal y otra de la osteotomía del olécranon. Hallamos 2 casos de neuroapraxias cubitales y una radial que se recuperaron sin secuelas. Hubo 3 reintervenciones: 2 retiradas de material y un caso de nueva osteosíntesis. Discusión. El tratamiento con reducción abierta y osteosíntesis con placa para las fracturas tipo A y C de húmero distal en ancianos proporciona unos resultados funcionales satisfactorios para las demandas de este tipo de paciente, lo que altera escasamente la calidad de vida percibida por los mismos (AU)


Introduction and objective. Distal humerus fractures in the elderly frequently associated with poor bone quality and comminution, making it harder to achieve proper osteosynthesis. Our aim is to evaluate the radiological and functional results of open reduction and internal fixation of these fractures. Material and methods. Retrospective study of 26 patients treated by open reduction and internal fixation between the years 2005-2010. Mean follow-up was 42 months. At final follow-up, a radiography evaluation (Knirk and Jupiter score) and clinical examination using Mayo Elbow Performance Score and Quick-Disabilities of the Arm, Shoulder and Hand Score was performed. Mean age of the group was 76.8 years (65-89), with 83% of the patients being female. Sixteen patients suffered type C fractures and 8 type A by AO classification. All underwent posterior surgical approach. Results. Mean elbow flexion reached 118.86°, with a mean extension deficit of 25°. More than 3-quarters (79.1%) of the patients showed 0-1 grade degenerative changes on the X-ray films at final follow-up. Functional results reached an average 19.87 points on Quick-Disabilities of the Arm, Shoulder and Hand Score, and 85 points on Mayo Elbow Performance Score scores. Non-union occurred in 2 cases: distal humerus in one patient and olecranon osteotomy in another. Ulnar nerve neuropraxia was recorded in 2 cases, and radial nerve in one. All 3 recovered uneventfully. Revision surgery was required, with 2 patients needing hardware removal and one a new fixation. Discussion. Treatment by open reduction and internal fixation with plating in elderly people for type A and C distal humerus fractures gives good functional results regarding this population, and thus scarcely disturbs their quality of life (AU)


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Humeral Fractures/surgery , Humeral Fractures , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/trends , Fracture Fixation, Internal , Antibiotic Prophylaxis/methods , Antibiotic Prophylaxis , Retrospective Studies , Pseudarthrosis/complications , Pseudarthrosis/diagnosis , Pseudarthrosis/surgery , Osteotomy/trends , Osteotomy , Arthrometry, Articular/methods , Arthrometry, Articular
2.
Rev Esp Cir Ortop Traumatol ; 58(1): 31-7, 2014.
Article in Spanish | MEDLINE | ID: mdl-24210637

ABSTRACT

INTRODUCTION AND OBJECTIVE: Distal humerus fractures in the elderly frequently associated with poor bone quality and comminution, making it harder to achieve proper osteosynthesis. Our aim is to evaluate the radiological and functional results of open reduction and internal fixation of these fractures. MATERIAL AND METHODS: Retrospective study of 26 patients treated by open reduction and internal fixation between the years 2005-2010. Mean follow-up was 42 months. At final follow-up, a radiography evaluation (Knirk and Jupiter score) and clinical examination using Mayo Elbow Performance Score and Quick-Disabilities of the Arm, Shoulder and Hand Score was performed. Mean age of the group was 76.8 years (65-89), with 83% of the patients being female. Sixteen patients suffered type C fractures and 8 type A by AO classification. All underwent posterior surgical approach. RESULTS: Mean elbow flexion reached 118.86°, with a mean extension deficit of 25°. More than 3-quarters (79.1%) of the patients showed 0-1 grade degenerative changes on the X-ray films at final follow-up. Functional results reached an average 19.87 points on Quick-Disabilities of the Arm, Shoulder and Hand Score, and 85 points on Mayo Elbow Performance Score scores. Non-union occurred in 2 cases: distal humerus in one patient and olecranon osteotomy in another. Ulnar nerve neuropraxia was recorded in 2 cases, and radial nerve in one. All 3 recovered uneventfully. Revision surgery was required, with 2 patients needing hardware removal and one a new fixation. DISCUSSION: Treatment by open reduction and internal fixation with plating in elderly people for type A and C distal humerus fractures gives good functional results regarding this population, and thus scarcely disturbs their quality of life.


Subject(s)
Fracture Fixation, Internal , Humeral Fractures/surgery , Aged , Aged, 80 and over , Female , Humans , Male , Retrospective Studies , Treatment Outcome
3.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 52(6): 381-385, nov. 2008. tab
Article in Es | IBECS | ID: ibc-69368

ABSTRACT

Introducción. Se realiza un estudio retrospectivo de una serie de espondilolistesis degenerativas de grado I y II, intervenidas quirúrgicamente llevando a cabo una fusión vertebral en un nivel, comparando la fusión circunferencial con la fusión posterolateral.Material y método. La serie consta de 33 pacientes (22 mujeres y 11 varones) que fueron intervenidos entre 1999 y 2002. En todos los casos se hizo un abordaje posterior y una artrodesis vertebral en un único nivel: en 15 pacientes se efectuó una artrodesis posterolateral (grupo 1) y en 18, una artrodesis circunferencial (grupo 2). La media de edad en el grupo 1 fue de 54,2 años (rango: 34-78 años) y el seguimiento mínimo, de 3 años (rango: 3-5,6 años). La media de edad en el grupo 2 fue de 50,8 años (rango: 25-76 años) y el seguimiento mínimo, de 3,2 años (rango: 3,2-5,5 años). Nohubo diferencias significativas en la edad entre ambos grupos. Analizamos los resultados clínicos con el cuestionario funcional SF-36 y con una valoración subjetiva del dolor por parte del paciente. Analizamos radiológicamente la fusión del espacio vertebral.Resultados. Las artrodesis circunferenciales obtienen unapuntuación media de 47,7 puntos en el SF-36, superior a los 38,4 puntos de las artrodesis posterolaterales. Los resultados radiológicos en cuanto a la obtención de la artrodesis son muy similares.Conclusiones. En nuestra experiencia, se obtienen mejoresresultados clínicos y radiológicos en el tratamiento quirúrgico de las espondilolistesis degenerativas cuando se realiza una artrodesis circunferencial


Introduction. A retrospective study was carried out of a series of grade I and II degenerative spondylolistheses subjected to a single-level fusion, comparing circumferential to posterolateral fusion.Materials and methods. Our series comprises 33 patients (22 females and 11 males) operated between 1999 and 2002. In all cases a single-level fusion was performed through a posterior approach: a posterolateral fusion was conducted in 15 patients (group 1), and a circumferential fusion in 18 (group 2). Mean age in group 1 was 54.2 years (range: 34-78), andfollow-up at least 3 years (range: 3-5.6 years). Mean age in group 2 was 50.8 years (range: 25-76 years) and follow-up at least 3.2 years (range: 3.2-5.5 years). There were no significant age-related differences between both groups. Clinical results were analyzed with the SF-36 functional scale and with a subjective pain assessment by the patient. We radiologicallyanalyzed fusion of the vertebral space.Results. Circumferential fusion obtained a mean score of47.7 points on the SF-36 scale vs 38.4 points for posterolateral fusion. X-ray results as to the success of the fusion procedure are very similar in both groups.Conclusions. In our experience, surgical treatment of degenerative spondylolistheses achieves better clinical and radiological results when a circumferential fusion is performed


Subject(s)
Humans , Spondylolisthesis/surgery , Spinal Fusion/methods , Arthrodesis/methods , Retrospective Studies
4.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 52(1): 15-20, ene. 2008. ilus, tab
Article in Es | IBECS | ID: ibc-64877

ABSTRACT

Objetivo. Análisis retrospectivo clínico y radiológico sobre los primeros casos intervenidos mediante cifoplastia en un centro de la Comunidad de Madrid. Material y método. Se revisaron 30 pacientes (43 vértebras) intervenidos entre diciembre 2002 y mayo 2005. La distribución etiológica fue: 24 pacientes con fractura osteoporótica y 6 con implantes tumorales líticos (1 caso de cáncer de pulmón, 2 de mama, un hipernefroma y 2 mielomas). El seguimiento medio fue de 13,2 meses. Se valoró la escala analógica visual (EAV), el índice de Karnosfky y la analgesia empleada antes del proceso y tras el seguimiento. También se midió el porcentaje de aplastamiento, el ángulo de Cobb local y la corrección de ambos. Resultados. El 93,2% de los pacientes mejoraron. La media de la EAV aumentó 5 puntos (p < 0,05). El índice de Karnosfky pasó de 70,63 a 90 puntos (p < 0,05). El 53% usaba opiáceos mayores antes de la cirugía, pasando el porcentaje después de la cirugía al 6,6% (p < 0,05). Veinte casos (46,5%) mejoraron radiológicamente. Excluyendo aquellas vértebras que no se corrigieron, la mejora obtenida fue de 21,7% de aplastamiento (rango 5-70%) y 13,86° de corrección ángulo de Cobb (rango 3-30°) respectivamente. Hubo 6 extravasaciones anterolaterales, todas asintomáticas. Se detectaron 2 fracturas adyacentes (ambas en los tres primeros meses tras la cirugía), una con repercusión clínica. En el subgrupo de pacientes tumorales los resultados finales fueron comparables a la serie general. Conclusiones. La mayoría de los casos mejoran sustancialmente sin complicaciones asociadas. La cifoplastia es una técnica de baja morbilidad y alta eficacia


Purpose. To conduct a retrospective clinical and radiological study of the first few cases operated by kyphoplasty at one center of Madrid. Materials and methods. Thirty patients were reviewed (43 vertebrae) who were operated between December 2002 and May 2005. The etiological distribution was as follows: 24 patients with an osteoporotic fracture and 6 with osteolytic tumors (lung cancer, 1 case; breast cancer, 2; hypernephroma, 1; and myeloma, 2). Mean follow-up was 13.2 months. Pain reduction was assessed by means of the Visual Analog Scale (VAS), the Karnosfky score and the amount of analgesia used before the procedure and during follow-up. Pre- and postoperative endplate angles were measured to assess the restoration of the sagittal alignment. Results. A 93.2% of patients improved. Mean VAS increased by 5 points (p < 0.05). Karnosfky score went from 70.63 to 90 points (p < 005). Patients using major opioids went from 53% befofre surgery to 6.6% postoperatively (p < 0.05). 20 cases (46.5%) showed radiological improvement. If we exclude uncorrected vertebrae, the improvement obtained was 21.7% as regards crushing (range: 5-70%) and 13.86° as regards Cobb's angle (range: 3-30°). There were 6 instances of anterolateral cement extravasation, all of them asymptomatic. Two adjoining fractures were detected (both in the first three months post-op), one of them with clinical repercussions. In the group of patients with tumors, final results were comparable to the general series. Conclusions. Most cases show a significant improvement with no associated complications. Kyphoplasty is a highly effective minimally invasive technique with a low degree of morbidity


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Spinal Injuries/surgery , Fracture Fixation, Internal/methods , Osteoporosis/complications , Fractures, Bone/surgery , Neoplasms/complications , Kyphosis/surgery , Retrospective Studies
5.
Rev. ortop. traumatol. (Madr., Ed. impr.) ; 49(3): 198-201, mayo-jun. 2005. ilus, tab
Article in Es | IBECS | ID: ibc-038699

ABSTRACT

Objetivo. Analizar las variaciones del comportamiento biomecánico mediante el análisis de elementos finitos de un segmento vertebral con un fijador transpedicular. Material y método. Se realizó un modelo matemático de elementos finitos (lineal, anisótropo y tridimensional) de un segmento vertebral lumbar (L1-L3) que fue sometido a cargas de compresión sucesivas de 1.177, 3.923 y 9.806 N. Posteriormente se incorporó al modelo un sistema de instrumentación transpedicular con las mismas cargas. Se estudió el desarrollo tensional del sistema, la redistribución de las cargas debidas al implante y las tensiones y deformaciones en el segmento instrumentado y del implante. Resultados. Los cambios en las distribuciones de las tensiones en el hueso, fueron de 502 MPa sin fijador y 460 MPa con fijador. El fijador produjo un aumento de la rigidez del 11,2%. Conclusiones. Este modelo de simulación 3D nos ha permitido estudiar el comportamiento de un segmento del raquis en diferentes situaciones y obtener datos que no son accesibles mediante los estudios experimentales, como la distribución de las concentraciones de tensiones


Aim. The aim of this study is to analyze variations in biomechanical behavior by finite-element analysis of a vertebral segment with transpedicular fixation. Materials and method. A finite-element mathematical model (linear, anisotropic, and three-dimensional) of a lumbar vertebral segment (L1-L3) that was subjected to successive compression loads of 1,177, 3,923, and 9,806 N. A transpedicular instrumentation system with the same loads was then added. The development of forces in the system, load redistribution due to the implant, and the forces and deformations in the instrumented segment and implant were studied. Results. The distribution of forces in the bone changed by 502 MPa without fixation and 460 MPa with fixation. Fixation increased resistance by 11.2%. Conclusions. This three-dimensional simulation model made it possible to study the behavior of a spinal segment in different situations and to obtain data not available from experimental studies, such as the distribution of force concentrations. Keywords: biomechanics, finite elements, spine, transpedicular fixation.En las últimas décadas se ha producido un aumento del uso instrumentaciones posteriores en las intervenciones del raquis que no se ha correlacionado con un conocimiento paralelo de las modificaciones que se producen1 . El estudio con modelos experimentales en el laboratorio es una forma directa de analizar el comportamiento del implante ante las cargas y, sin embargo, presenta una serie de limitaciones. Resulta muy difícil evaluar el desarrollo tensional y la redistribución de las cargas del sistema. Además, existe el problema de la dispersión de datos por la utilización de tejidos orgánicos. La metodología matemática de los elementos finitos nos permite superar estos problemas2 .En este estudio se analizan las variaciones del comportamiento biomecánico mediante el análisis de elementos finitos de un segmento vertebral al añadir un fijador transpedicular


Subject(s)
Humans , Computer Simulation , Biomechanical Phenomena/methods , Lumbar Vertebrae , External Fixators
SELECTION OF CITATIONS
SEARCH DETAIL
...