Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Biophys J ; 120(2): 254-269, 2021 01 19.
Article in English | MEDLINE | ID: mdl-33345902

ABSTRACT

Förster resonance energy transfer (FRET) is a powerful tool to investigate the interaction between proteins in living cells. Fluorescence proteins, such as the green fluorescent protein (GFP) and its derivatives, are coexpressed in cells linked to proteins of interest. Time-resolved fluorescence anisotropy is a popular tool to study homo-FRET of fluorescent proteins as an indicator of dimerization, in which its signature consists of a very short component at the beginning of the anisotropy decay. In this work, we present an approach to study GFP homo-FRET via a combination of time-resolved fluorescence anisotropy, the stretched exponential decay model, and molecular dynamics simulations. We characterize a new, to our knowledge, FRET standard formed by two enhanced GFPs (eGFPs) and a flexible linker of 15 aminoacids (eGFP15eGFP) with this protocol, which is validated by using an eGFP monomer as a reference. An excellent agreement is found between the FRET efficiency calculated from the fit of the eGFP15eGFP fluorescence anisotropy decays with a stretched exponential decay model (〈EFRETexp〉 = 0.25 ± 0.05) and those calculated from the molecular dynamics simulations (〈EFRETMD〉 = 0.18 ± 0.14). The relative dipole orientation between the GFPs is best described by the orientation factors 〈κ2〉 = 0.17 ± 0.16 and 〈|κ|〉 = 0.35 ± 0.20, contextualized within a static framework in which the linker hinders the free rotation of the fluorophores and excludes certain configurations. The combination of time- and polarization-resolved fluorescence spectroscopy with molecular dynamics simulations is shown to be a powerful tool for the study and interpretation of homo-FRET.


Subject(s)
Fluorescence Resonance Energy Transfer , Molecular Dynamics Simulation , Fluorescence Polarization , Green Fluorescent Proteins/genetics , Microscopy, Fluorescence
2.
Phys Chem Chem Phys ; 20(23): 16060-16066, 2018 Jun 13.
Article in English | MEDLINE | ID: mdl-29850681

ABSTRACT

Environmentally-sensitive membrane dyes have been extensively used to study the different liquid phases, (liquid-ordered (Lo) and liquid-disordered (Ld)) of the heterogenous cellular membrane. However, it is not yet well understood how these dyes affect membrane properties upon and post insertion. Using a combination of molecular dynamics (MD) simulations and fluorescence microscopy, we study the effect of PRODAN insertion upon its local environment. We firstly present the results of the MD simulations of PRODAN interacting with lipid bilayers of various compositions, specifically the resultant hydration and lipid order of the system. Experimentally, the lipid order of Lo and Ld vesicles containing various concentrations of PRODAN are inferred from their Generalised Polarisation (GP) values, calculated using their fluorescence spectra. We then apply the methodology to a more complex biological system, the HeLa cell line. For both systems, the presence of PRODAN influences its local environment differently between the Lo and Ld phases. In the simulated systems, the presence of PRODAN lowers the lipid order in the Ld phase and increases the order in the Lo phase, whilst experimental data demonstrates that even a small increase in PRODAN concentration significantly lowers the order of both phases. We suggest this discrepancy may be ascribed to the differing localisations of the dye molecules within the bilayer, and their effect on the hydration of adjacent lipids.

4.
J Biophotonics ; 10(9): 1124-1133, 2017 Sep.
Article in English | MEDLINE | ID: mdl-27943625

ABSTRACT

Fluorescence Lifetime Imaging (FLIM) is an attractive microscopy method in the life sciences, yielding information on the sample otherwise unavailable through intensity-based techniques. A novel Noise-Corrected Principal Component Analysis (NC-PCA) method for time-domain FLIM data is presented here. The presence and distribution of distinct microenvironments are identified at lower photon counts than previously reported, without requiring prior knowledge of their number or of the dye's decay kinetics. A noise correction based on the Poisson statistics inherent to Time-Correlated Single Photon Counting is incorporated. The approach is validated using simulated data, and further applied to experimental FLIM data of HeLa cells stained with membrane dye di-4-ANEPPDHQ. Two distinct lipid phases were resolved in the cell membranes, and the modification of the order parameters of the plasma membrane during cholesterol depletion was also detected. Noise-corrected Principal Component Analysis of FLIM data resolves distinct microenvironments in cell membranes of live HeLa cells.


Subject(s)
Cell Membrane , Image Enhancement/methods , Microscopy, Fluorescence , Optical Imaging , HeLa Cells , Humans , Photons , Principal Component Analysis
5.
Biomaterials ; 104: 182-91, 2016 10.
Article in English | MEDLINE | ID: mdl-27454064

ABSTRACT

Quantum dots (QDs) are attractive photoluminescence probes for biomedical imaging due to their unique photophysical properties. However, the potential toxicity of QDs has remained a major obstacle to their clinical use because they commonly incorporate the toxic heavy metal cadmium within the core of the QDs. In this work, we have evaluated a novel type of heavy metal-free/cadmium-free and biocompatible QD nanoparticles (bio CFQD(®) nanoparticles) with a good photoluminescence quantum yield. Sentinel lymph node mapping is an increasingly important treatment option in the management of breast cancer. We have demonstrated their potential for lymph node mapping by ex vivo imaging of regional lymph nodes after subcutaneous injection in the paw of rats. Using photoluminescence imaging and chemical extraction measurements based on elemental analysis by inductively coupled plasma mass spectroscopy, the quantum dots are shown to accumulate quickly and selectively in the axillary and thoracic regional lymph nodes. In addition, lifetime imaging microscopy of the QD photoluminescence indicates minimal perturbation to their photoluminescence properties in biological systems.


Subject(s)
Luminescent Measurements/methods , Metal Nanoparticles/chemistry , Quantum Dots/chemistry , Sentinel Lymph Node/chemistry , Sentinel Lymph Node/pathology , Animals , Female , Indium/chemistry , Metals, Heavy , Rats , Reproducibility of Results , Sensitivity and Specificity , Tissue Distribution
6.
Proc Natl Acad Sci U S A ; 112(20): E2569-74, 2015 May 19.
Article in English | MEDLINE | ID: mdl-25931526

ABSTRACT

The specialized light organ of the ponyfish supports the growth of the bioluminescent symbiont Photobacterium leiognathi. The bioluminescence of P. leiognathi is generated within a heteromeric protein complex composed of the bacterial luciferase and a 20-kDa lumazine binding protein (LUMP), which serves as a Förster resonance energy transfer (FRET) acceptor protein, emitting a cyan-colored fluorescence with an unusually long excited state lifetime of 13.6 ns. The long fluorescence lifetime and small mass of LUMP are exploited for the design of highly optimized encoded sensors for quantitative fluorescence anisotropy (FA) measurements of protein hydrodynamics. In particular, large differences in the FA values of the free and target-bound states of LUMP fusions appended with capture sequences of up to 20 kDa are used in quantitative FA imaging and analysis of target proteins. For example, a fusion protein composed of LUMP and a 5-kDa G protein binding domain is used as an FA sensor to quantify the binding of the GTP-bound cell division control protein 42 homolog (Cdc42) (21 kDa) in solution and within Escherichia coli. Additionally, the long fluorescence lifetime and the surface-bound fluorescent cofactor 6,7-dimethyl-8- (1'-dimethyl-ribityl) lumazine in LUMP are utilized in the design of highly optimized FRET probes that use Venus as an acceptor probe. The efficiency of FRET in a zero-length LUMP-Venus fusion is 62% compared to ∼ 31% in a related CFP-Venus fusion. The improved FRET efficiency obtained by using LUMP as a donor probe is used in the design of a FRET-optimized genetically encoded LUMP-Venus substrate for thrombin.


Subject(s)
Bacterial Proteins , Fluorescence Polarization/methods , Luminescent Proteins , Molecular Probes , Multiprotein Complexes , Proteins/analysis , Bacterial Proteins/genetics , Bacterial Proteins/metabolism , DNA Primers/genetics , Escherichia coli , Fluorescence Resonance Energy Transfer , Genetic Engineering/methods , Hydrodynamics , Image Processing, Computer-Assisted , Luminescent Proteins/genetics , Luminescent Proteins/metabolism , Microscopy, Confocal , Molecular Probes/metabolism , Multiprotein Complexes/genetics , Multiprotein Complexes/metabolism , Plasmids/genetics , Thrombin/analysis , cdc42 GTP-Binding Protein/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...