Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Ophthalmol ; 2021: 8448996, 2021.
Article in English | MEDLINE | ID: mdl-34552765

ABSTRACT

PURPOSE: To evaluate the outcomes and safety of a minimally invasive technique for sutured IOL scleral fixation in case of compromised capsular and iris support. MATERIALS AND METHODS: In this retrospective study, we explain our mini-invasive technique and assess the outcomes in terms of visual acuity, pre- or postoperative complications, and IOL position (Sensar AR40e, AMO) in a case series of three patients. RESULTS: The expected best corrected visual acuity could be achieved after one month. Surgeries were uneventful with a stable eye. No postoperative complications occurred except for one patient who had a conjunctival disinsertion. Neither postoperative hypotony nor raised IOP was found. Additionally, no patient experienced corneal edema at one week control, IOL dislocation, vitreous hemorrhage, or new pupil's irregularity. CONCLUSIONS: In conclusion, each scleral technique has its own advantages and its inherent postoperative complications. To date, there is no evidence of superiority of any single technique. By improving our scleral sutured lens techniques, we could improve peroperative ocular stability, potentially decrease postoperative complication rate, and offer a rapid recovery with a stable visual acuity within a month.

2.
J Int Med Res ; 47(1): 188-195, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30270801

ABSTRACT

This series of case reports describes six eyes from five patients that underwent intraocular lens (IOL) exchange with scleral-fixated IOLs for cystoid macular oedema associated with iris-fixated IOLs between 2005 and 2015. Macular oedema was assessed using ocular coherence tomography (OCT). The six eyes in this series were treated by IOL removal and implantation of a scleral -sutured IOL with four points of fixation in the sulcus. Visual acuity improved in all six eyes. On OCT, macular oedema resolved after 3 months in all eyes. There were no surgical complications from the IOL exchange. One eye had a pupilloplasty and another had a diaphragm IOL to treat a major iris impairment from prior surgeries. The cause of cystoid macular oedema in these cases remains controversial but has been well recognized in eyes with iris-sutured IOLs. The absence of sutures with posterior fixation of an iris claw IOL prevents progressive corneal endothelial cell loss but does not prevent macular oedema, even in vitrectomized eyes. In conclusion, macular oedema resolved and visual acuity improved after implant exchange with a secondary scleral-fixated IOL in these cases. This procedure should be considered as a solution to persistent symptomatic cystoid macular oedema from an iris-fixated implant.


Subject(s)
Iris/surgery , Lens Implantation, Intraocular/methods , Lens, Crystalline/surgery , Lenses, Intraocular/adverse effects , Macular Edema/surgery , Aged , Female , Humans , Lens, Crystalline/pathology , Macular Edema/etiology , Macular Edema/pathology , Male , Middle Aged , Reoperation/methods , Sclera/surgery , Suture Techniques , Tomography, Optical Coherence , Treatment Outcome , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...