Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
JAMA Cardiol ; 8(3): 248-256, 2023 03 01.
Article in English | MEDLINE | ID: mdl-37070491

ABSTRACT

Importance: Evidence is scarce on the effectiveness of simulation-based training in transesophageal echocardiography (TEE). Objective: To assess the effectiveness of simulation-based teaching vs traditional teaching of TEE knowledge and skills of cardiology fellows. Design, Setting, and Participants: Between November 2020 and November 2021, all consecutive cardiology fellows inexperienced in TEE from 42 French university centers were randomized (1:1; n = 324) into 2 groups with or without simulation support. Main Outcomes and Measures: The co-primary outcomes were the scores in the final theoretical and practical tests 3 months after the training. TEE duration and the fellows' self-assessment of their proficiency were also assessed. Results: While the theoretical and practical test scores were similar between the 2 groups (324 participants; 62.6% male; mean age, 26.4 years) before the training (33.0 [SD, 16.3] points vs 32.5 [SD, 18.5] points; P = .80 and 44.2 [SD, 25.5] points vs 46.1 [SD, 26.1] points; P = .51, respectively), the fellows in the simulation group (n = 162; 50%) displayed higher theoretical test and practical test scores after the training than those in the traditional group (n = 162; 50%) (47.2% [SD, 15.6%] vs 38.3% [SD, 19.8%]; P < .001 and 74.5% [SD, 17.7%] vs 59.0% [SD, 25.1%]; P < .001, respectively). Subgroup analyses showed that the effectiveness of the simulation training was even greater when performed at the beginning of the fellowship (ie, 2 years or less of training) (theoretical test: an increase of 11.9 points; 95% CI, 7.2-16.7 vs an increase of 4.25 points; 95% CI, -1.05 to 9.5; P = .03; practical test: an increase of 24.9 points; 95% CI, 18.5-31.0 vs an increase of 10.1 points; 95% CI, 3.9-16.0; P < .001). After the training, the duration to perform a complete TEE was significantly lower in the simulation group than in the traditional group ( 8.3 [SD, 1.4] minutes vs 9.4 [SD, 1.2] minutes; P < .001, respectively). Additionally, fellows in the simulation group felt more ready and more confident about performing a TEE alone after the training (mean score, 3.0; 95% CI, 2.9-3.2 vs mean score, 1.7; 95% CI, 1.4-1.9; P < .001 and mean score, 3.3; 95% CI, 3.1-3.5 vs mean score, 2.4; 95% CI, 2.1-2.6; P < .001, respectively). Conclusions and Relevance: Simulation-based teaching of TEE showed a significant improvement in the knowledge, skills, and self-assessment of proficiency of cardiology fellows, as well as a reduction in the amount of time needed to complete the examination. These results should encourage further investigation of clinical performance and patient benefits of TEE simulation training.


Subject(s)
Internship and Residency , Simulation Training , Humans , Male , Adult , Female , Echocardiography, Transesophageal/methods , Clinical Competence , Computer Simulation
2.
J Nucl Cardiol ; 30(1): 405-407, 2023 02.
Article in English | MEDLINE | ID: mdl-34346029

ABSTRACT

We herein report the case of a 74-year-old man with recurrent transient ischemic attacks and falls who was found to have an unusual large mass of the interventricular septum. After extensive workup, isolated myocardial calcification was confirmed using multimodality cardiovascular imaging. This rare finding might be a reflecting cause of the patient's clinical presentation.


Subject(s)
Cardiomyopathies , Ischemic Attack, Transient , Ventricular Septum , Male , Humans , Aged , Cardiomyopathies/complications , Ischemic Attack, Transient/etiology
3.
Diabetes Metab ; 48(2): 101321, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35032674

ABSTRACT

OBJECTIVE: To investigate the glycemic balance before, during and after the 2016 Paris Marathon using a real-time continuous glucose monitoring (RT-CGM) system in patients with type 1 diabetes mellitus in a prospective single-center observational study. METHODS: Inclusion criteria were as follows: type 1 diabetes mellitus; age ≥18 years; HbA1c < 9%. Participants performed two 2h-preparatory races (PR) before the Marathon and were monitored with RT-CGM 24h before, during and 72h after each race. Hypoglycemic events were prevented via carbohydrate intake / insulin dose adjustments. The primary outcome was area under the curve (AUC) < 70 and > 200 mg/dl and percentage of time spent in euglycemia, hypoglycemia, and hyperglycemia during the races. RESULTS: Twelve patients (2F/10M; median HbA1c=6.8%) were included and completed the study. Median AUC < 70 and time spent in hypoglycemia (< 70 mg/dl) during the PRs and Marathon were equal to 0. However, no hypoglycemic episodes occurred during Marathon, while two patients experienced hypoglycemia during PR1 and PR2. There was a significant increase in AUC > 200 mg/dl during races between PR2 and Marathon (P = 0.009) although the median time spent > 200mg/dl was not statistically different in Marathon versus PR2 (48.4% versus 18.4%; P = 0.09). Median time spent in euglycemia (70-200 mg/dl) was lower in Marathon versus PR2 (51.6 versus 58%; P = 0.03). CONCLUSION: Our study proposes a medical support protocol for extreme endurance physical activity in patients with type 1 diabetes mellitus. Our results suggest that RT-CGM, coupled with adjustments in carbohydrate intake and insulin doses, appears to be effective to prevent hypoglycemia during and after exercise.


Subject(s)
Diabetes Mellitus, Type 1 , Hypoglycemia , Adolescent , Blood Glucose , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 1/drug therapy , Glycated Hemoglobin/analysis , Humans , Hypoglycemia/chemically induced , Hypoglycemic Agents/adverse effects , Insulin/therapeutic use , Marathon Running , Paris/epidemiology , Prospective Studies
4.
J Interv Card Electrophysiol ; 64(1): 27-34, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34002319

ABSTRACT

BACKGROUND: The prevalence of peri-device leak (PDL) of left atrial appendage occlusion (LAAO) devices has been previously reported. However, there have been only few data that compared different existing devices. The aim of this study was to assess the incidence of PDL with both devices WATCHMAN®, Boston Scientific and AMPLATZER Amulet®, Abbott Laboratories and to evaluate the clinical outcome at 12 months. METHODS: Consecutive patients who underwent LAAO between January 2018 and 2020 were randomly assigned to either WATCHMAN or AMPLATZER Amulet implantation based on a systematic 2-week alternation between both devices. LAA measurements were assessed using cardiac computed tomography angiography (CCTA) prior to and transesophageal echocardiography (TEE) during the procedure. At 8 weeks post-LAAO, patients underwent TEE and/or CCTA to identify the presence of PDL and/or device-related complications. Patients were then followed for 12 months to identify major adverse cardiovascular/embolic events. RESULTS: The cohort consisted of 51 patients (25 WATCHMAN, 26 AMPLATZER Amulet; mean age 76 ± 7 years; male gender 76%). Both groups were identically matched for demographics, comorbidities, and indication for LAAO. There were 19 patients who had PDL (13 WATCHMAN vs. 6 AMPLATZER Amulet, P-value = 0.033). Of them, 8 (15%) patients had significant PDL (7 WATCHMAN vs. 1 AMPLATZER Amulet, P-value = 0.018). On CCTA, the landing zone maximal diameter of the AMPLATZER Amulet device had the strongest correlation with the final deployed device size (Spearman's rho 0.92, P-value < 0.0001). In the multivariate analysis, male gender and device type were independent predictors of any PDL (P-values 0.016 and 0.031, respectively). On a mean follow-up of 12 months, the total number of events was more prevalent in the WATCHMAN group (P-value 0.008), but the incidence of cardio-embolic events reached borderline significance (16% vs. 0%, P-value = 0.051). CONCLUSIONS: Among patients who underwent LAAO, almost 15% had significant PDL with the majority belonging to the WATCHMAN group. Still, larger studies are warranted to evaluate its effectiveness in stroke prevention.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Septal Occluder Device , Aged , Aged, 80 and over , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Cardiac Catheterization/adverse effects , Computed Tomography Angiography/methods , Echocardiography, Transesophageal/methods , Humans , Male , Treatment Outcome
5.
Echocardiography ; 38(9): 1647-1651, 2021 09.
Article in English | MEDLINE | ID: mdl-34585439

ABSTRACT

BACKGROUND: Cardiac masses may be incidentally found or in relation to the clinical presentation. Depending on the complexity of the lesion, a multimodality imaging approach may be necessary for a proper diagnosis. CASE REPORT: We report the case of a 64-year-old male patient who was referred for pre-chemotherapy work-up of a metastatic scrotal melanoma. Echocardiography showed incidental heterogeneous left atrial mass. Further investigation using cardiovascular magnetic resonance imaging, computed tomography angiography, and positron emission tomography confirmed the findings that were consistent with a left atrial myxoma vascularized by a left circumflex coronary-cameral fistula. CONCLUSIONS: When the clinical context may be misleading, assessment of a cardiac mass with a multimodality approach is essential in order to define its exact benign or malignant nature.


Subject(s)
Heart Neoplasms , Myxoma , Echocardiography , Heart Neoplasms/diagnostic imaging , Humans , Male , Middle Aged , Multimodal Imaging , Myxoma/diagnostic imaging , Tomography, X-Ray Computed
6.
J Clin Med ; 10(15)2021 Jul 22.
Article in English | MEDLINE | ID: mdl-34362005

ABSTRACT

Mean Gradient (MG) elevation can be detected immediately after transcatheter aortic valve implantation (TAVI) or secondarily during follow-up. Comparisons and interactions between these two parameters and their impact on outcomes have not previously been investigated. This study aimed to identify incidence, influence on prognosis, and parameters associated with immediate high post-procedural mean transvalvular gradient (PPMG) and delayed mean gradient increase (6 to 12 months after TAVI, DMGI) in the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry. The registry includes all consecutive symptomatic patients with severe aortic stenosis who have undergone TAVI. Three groups were analyzed: (1) PPMG < 20 mmHg without DMGI > 10 mmHg (control); (2) PPMG < 20 mmHg with DMGI > 10 mmHg (Group 1); and (3) PPMG ≥ 20 mmHg (Group 2). From January 2010 to January 2012, 4201 consecutive patients were prospectively enrolled in the registry. Controls comprised 2078 patients. In Group 1(n = 131 patients), DMGI exceeded 10 mmHg in 5.6%, and was not associated with greater 4-years mortality than in controls (32.6% vs. 40.1%, p = 0.27). In Group 2 (n = 144 patients), PPMG was at least 20 mmHg in 6.1% and was associated with higher 4-year mortality (48.7% versus 40.1%, p = 0.005). A total of two-thirds of the patients with PPMG ≥ 20 mmHg had MG < 20 mmHg at 1 year, with mortality similar to the controls (39.2% vs. 40.1%, p = 0.73). Patients with PPMG > 20 mmHg 1 year post-TAVI had higher 4-years mortality than the general population of the registry, unlike patients with MG normalization.

7.
Front Cardiovasc Med ; 8: 661355, 2021.
Article in English | MEDLINE | ID: mdl-34109225

ABSTRACT

Introduction: Simulation-based training in transesophageal echocardiography (TEE) seems promising. However, data are limited to non-randomized or single-center studies. To assess the impact of simulation-based vs. traditional teaching on TEE knowledge and performance for medical residents in cardiology. Materials and Methods: Nationwide prospective randomized multicenter study involving 43 centers throughout France allowing for the inclusion of >70% of all French cardiology residents. All cardiology residents naive from TEE will be included. Randomization with stratification by center will allocate residents to either a control group receiving theoretical knowledge by e-learning only, or to an intervention group receiving two simulation-based training sessions on a TEE simulator in addition. Results: All residents will undergo both a theoretical test (0-100 points) and a practical test on a TEE simulator (0-100 points) before and 3 months after the training. Satisfaction will be assessed by a 5-points Likert scale. The primary outcomes will be to compare the scores in the final theoretical and practical tests between the two groups, 3 months after the completion of the training. Conclusion: Data regarding simulation-based learning in TEE are limited to non-randomized or single-center studies. The randomized multicenter SIMULATOR study will assess the impact of simulation-based vs. traditional teaching on TEE knowledge and performance for medical residents in cardiology, and whether such an educational program should be proposed in first line for TEE teaching.

8.
Arch Cardiovasc Dis ; 114(4): 325-335, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33888446

ABSTRACT

This paper is intended to update the former consensus between the French Societies of Radiology and Cardiology about the use of stress cardiac magnetic resonance imaging in chronic coronary syndrome, published in 2009. The Delphi method was used to build the present consensus. This expert panel consensus includes recommendations for indications, the procedure (with patient preparation), stress-inducing drugs, the acquisition protocol, interpretation and risk stratification by stress magnetic resonance imaging.


Subject(s)
Adrenergic beta-Agonists/administration & dosage , Coronary Circulation/drug effects , Hemodynamics/drug effects , Magnetic Resonance Imaging , Myocardial Ischemia/diagnostic imaging , Vasodilator Agents/administration & dosage , Adult , Aged , Chronic Disease , Consensus , Delphi Technique , Female , Humans , Male , Middle Aged , Myocardial Ischemia/physiopathology , Predictive Value of Tests , Prognosis
9.
Diagn Interv Imaging ; 102(6): 337-345, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33712412

ABSTRACT

This position paper was intended to update the former consensus between the French Societies of Radiology and Cardiology about the use of stress cardiac magnetic resonance imaging (MRI) in chronic coronary syndrome published in 2009. The Delphi method was used to build the present consensus. This expert panel consensus includes recommendations for indications, procedure with patient preparation, stress inducing drugs, acquisition protocol, interpretation and risk stratification by stress MRI.


Subject(s)
Magnetic Resonance Imaging , Consensus , France , Humans , Syndrome
10.
Eur Heart J Cardiovasc Imaging ; 22(2): 229-235, 2021 01 22.
Article in English | MEDLINE | ID: mdl-32187352

ABSTRACT

AIMS: Fifteen to thirty percentage of patients with severe aortic stenosis (AS) have preserved left ventricular ejection fraction (LVEF) and a discordant AS pattern at Doppler echocardiography, which is characterized by a small (<1 cm2) aortic area and low mean aortic gradient (<40 mmHg). The 'Randomized study for the Optimal Treatment of symptomatic patients with low-gradient severe Aortic Stenosis and preserved left ventricular ejection fraction' (ROTAS trial) aims at demonstrating the superiority of aortic valve replacement vs. a 'watchful waiting strategy' in symptomatic patients with low-gradient (LS), severe AS, and preserved LVEF, stratified according to indexed stroke volume, in terms of all-cause mortality or cardiovascular-related hospitalization during follow-up (FU). METHODS AND RESULTS: The ROTAS trial will be a multicentre randomized non-blinded study involving 16 reference centres. AS severity will be confirmed by a multimodality approach (rest and stress echocardiography, calcium scoring, and cardiac magnetic resonance imaging for optimally characterize the population), which could provide important inputs to improve the pathophysiological understanding of this complex disease. Well-characterized patients will be randomized according to the management strategy. The primary endpoint will be the occurrence of all-cause mortality or cardiac related-hospitalizations during 2-year FU. One hundred and eighty subjects per group will be included. CONCLUSION: The management of patients with LS severe AS and preserved LVEF is largely debated. ROTAS trial will allow a comprehensive evaluation of this particular pattern of AS and will establish which is the most appropriate management of these patients.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Prognosis , Severity of Illness Index , Stroke Volume , Treatment Outcome , Ventricular Function, Left
11.
J Am Soc Echocardiogr ; 34(1): 62-71, 2021 01.
Article in English | MEDLINE | ID: mdl-33067075

ABSTRACT

BACKGROUND: Transthoracic echocardiography (TTE) is the reference method for evaluation of aortic stenosis (AS), and it is extensively used to quantitate left ventricular (LV) mass and volumes. Regional upper septal hypertrophy (USH) or septal bulge is a frequent finding in patients with AS and may lead to overestimation of LV mass when using linear measurements. The objective of this study was to compare estimates of LV mass obtained by two-dimensional transthoracic echocardiographic LV dimensions measured at different levels of the LV cavity with those obtained by cardiovascular magnetic resonance (CMR). METHODS: One hundred six patients (mean age, 63 ± 15 years; 68% men) with AS were included in this subanalysis of the PROGRESSA study. Two-dimensional transthoracic echocardiographic measurements of LV dimensions were obtained at the basal level (BL; as recommended in guidelines), immediately below the septal bulge (BSB), and at a midventricular level (ML). Regional USH was defined as a basal interventricular septal thickness ≥ 13 mm and >1.3 times the thickness of the septal wall at the ML. Agreement between transthoracic echocardiographic and CMR measures was evaluated using Bland-Altman analysis. RESULTS: The distribution of AS severity was mild in 23%, moderate in 57%, and severe in 20% of patients. Regional USH was present in 28 patients (26%). In the whole cohort, two-dimensional TTE overestimated LV mass (bias: BL, +60 ± 31 g; BSB, +59 ± 32 g; ML, +54 ± 32 g; P = .02). The biplane Simpson method slightly but significantly underestimated LV end-diastolic volume (bias -10 ± 20 mL, P < .001) compared with CMR. Overestimation of LV mass was more marked in patients with USH when measuring at the BL and was significantly lower when measuring LV dimensions at the ML (P < .025 vs BL and BSB). CONCLUSIONS: Two-dimensional TTE systematically overestimated LV mass and underestimated LV volumes compared with CMR. However, the bias between TTE and CMR was less important when measuring at the ML. Measurements at the BL as suggested in guidelines should be avoided, and measurements at the ML should be preferred in patients with AS, especially in those with USH.


Subject(s)
Aortic Valve Stenosis , Echocardiography , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/diagnostic imaging , Female , Heart Ventricles/diagnostic imaging , Humans , Hypertrophy , Hypertrophy, Left Ventricular/diagnostic imaging , Male , Middle Aged , Reproducibility of Results
12.
J Am Soc Echocardiogr ; 33(8): 953-963.e5, 2020 08.
Article in English | MEDLINE | ID: mdl-32580897

ABSTRACT

BACKGROUND: In aortic stenosis, accurate measurement of left ventricular stroke volume (SV) is essential for the calculation of aortic valve area (AVA) and the assessment of flow status. Current American Society of Echocardiography and European Association of Cardiovascular Imaging guidelines suggest that measurements of left ventricular outflow tract diameter (LVOTd) at different levels (at the annulus vs 5 or 10 mm below) yield similar measures of SV and AVA. The aim of this study was to assess the effect of the location of LVOTd measurement on the accuracy of SV and AVA measured on transthoracic echocardiography (TTE) compared with cardiovascular magnetic resonance (CMR). METHODS: One hundred six patients with aortic stenosis underwent both TTE and CMR. SV was estimated on TTE using the continuity equation with LVOTd measurements at four locations: at the annulus and 2, 5, and 10 mm below annulus. SV was also determined on CMR using phase contrast acquired in the aorta (SVCMR-PC), and a hybrid AVACMR-PC was calculated by dividing SVCMR-PC by the transthoracic echocardiographic Doppler aortic velocity-time integral. Comparison between methods was made using Bland-Altman analysis. RESULTS: Compared with the referent method of phase-contrast CMR for the estimation of SVCMR-PC and AVACMR-PC (SVCMR-PC 83 ± 16 mL, AVACMR-PC 1.27 ± 0.35 cm2), the best agreement was obtained by measuring LVOTd at the annulus or 2 mm below (P = NS), whereas measuring 5 and 10 mm below the annulus resulted in significant underestimation of SV and AVA by up to 15.9 ± 17.3 mL and 0.24 ± 0.28 cm2, respectively (P < .01 for all). Accuracy for classification of low flow was best at the annulus (86%) and 2 mm below (82%), whereas measuring 5 and 10 mm below the annulus significantly underperformed (69% and 61%, respectively, P < .001). CONCLUSIONS: Measuring LVOTd at the annulus or very close to it provides the most accurate measures of SV and AVA, whereas measuring LVOTd 5 or 10 mm below significantly underestimates these parameters and leads to significant overestimation of the severity of aortic stenosis and prevalence of low-flow status.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Echocardiography , Humans , Magnetic Resonance Spectroscopy , Reproducibility of Results , Severity of Illness Index , Stroke Volume
14.
JACC Cardiovasc Interv ; 13(5): 567-579, 2020 03 09.
Article in English | MEDLINE | ID: mdl-32061600

ABSTRACT

OBJECTIVES: This study sought to determine the incidence, clinical impact, and changes over time of mitral regurgitation (MR) in patients with low-flow, low-gradient aortic stenosis (LFLG-AS) undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Few data exist on the clinical impact and changes in severity over time of MR in patients with LFLG-AS undergoing TAVR. METHODS: A total of 308 TAVR candidates with LFLG-AS were included. Patients were categorized according to MR severity at baseline, and presence of MR improvement at 12-month follow-up. Clinical outcomes were assessed at 1 and 12 months (+ echocardiography), and yearly thereafter. RESULTS: Baseline mild and moderate-to-severe MR were present in 118 (38.3%) and 115 (37.3%) patients, respectively. MR was of functional and mixed etiology in 77.2% and 22.7% of patients, respectively. A total of 131 patients (42.5%) died after a median follow-up of 2 (1 to 3) years. Baseline moderate-or-greater MR had no impact on mortality (hazard ratio [HR]: 1.34; 95% confidence interval [CI]: 0.72 to 2.48) or heart failure hospitalization (HR: 1.02; 95% CI: 0.49 to 2.10). At 1-year follow-up, MR improved in 44.3% of patients and remained unchanged/worsened in 55.7%. The lack of MR improvement was associated with a higher risk of all-cause and cardiac mortality (HR: 2.02; 95% CI: 1.29 to 3.17; HR: 3.03; 95% CI: 1.27 to 7.23, respectively), rehospitalization for cardiac causes (HR: 1.50; 95% CI: 1.04 to 2.15), and an increased overall-mortality/heart failure rehospitalization (HR: 1.94; 95% CI: 1.25 to 3.02). A higher baseline left ventricular end-diastolic diameter and a higher increase in left ventricular ejection fraction were found to be independent predictors of MR improvement at 1-year follow-up (odds ratio: 0.69; 95% CI: 0.51 to 0.94; and odds ratio: 0.81; 95% CI: 0.67 to 0.96, respectively). CONCLUSIONS: Most TAVR candidates with LFLG-AS had some degree of MR, of functional origin in most cases. MR improved in about one-half of patients, with larger left ventricular size and a higher increase in left ventricular ejection fraction post-TAVR determining MR improvement over time. The lack of MR improvement at 1 year was associated with poorer outcomes.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Hemodynamics , Mitral Valve Insufficiency/physiopathology , Mitral Valve/physiopathology , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Disease Progression , Female , Heart Failure/physiopathology , Heart Failure/therapy , Heart Valve Prosthesis , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Patient Readmission , Prospective Studies , Recovery of Function , Registries , Retrospective Studies , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
15.
Arch Cardiovasc Dis ; 113(1): 22-30, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31862377

ABSTRACT

BACKGROUND: Several studies have highlighted the relationship between weather patterns and the occurrence of ST-elevation myocardial infarction (STEMI). AIM: To evaluate the statistical association between the occurrence of STEMI and meteorological variables over the preceding 7 days. METHODS: This was a retrospective study, using prespecified data from the ORBI (Breton Regional Observatory on Myocardial Infarction) registry, which includes all consecutive patients hospitalized for STEMI in the geographical area of Brest, France. Over a 7-year period, we compared the number of STEMIs per week with the mean values of meteorological variables over the preceding 7 days. RESULTS: Overall, 7517 patients with STEMI were recorded in the ORBI registry between January 2009 and January 2016. After exclusion of patients not living in the geographical area of interest, 742 patients were included. The weekly incidence of STEMI ranged from 0 to 7 (median 2, interquartile range 1-3). In the univariate analysis, air temperature (odds ratio [OR] 1.05, 95% confidence interval [CI] 1.005-1.01 per 1°C decrease; P=0.03) and atmospheric pressure (OR 1.03, 95% CI 1.01-1.06 per 1 hPa increase; P=0.008) were associated with the weekly incidence of STEMI. In the multivariable analysis, air temperature (OR 1.06, 95% CI 1.01-1.10 per 1°C decrease; P=0.01), atmospheric pressure (OR 1.05, 95% CI 1.02-1.08 per 1 hPa increase; P<0.001) and duration of humidity>80% (OR 1.09, 95% CI 1.02-1.15 per 1hour increase; P=0.007) in the previous 7 days were associated with the occurrence of STEMI. CONCLUSIONS: In this specific geographical area, occurrence of STEMI was statistically associated with a decrease in air temperature, an increase in atmospheric pressure and an increase in humidity over the preceding 7-day period.


Subject(s)
ST Elevation Myocardial Infarction/epidemiology , Weather , Aged , Atmospheric Pressure , Female , France/epidemiology , Humans , Humidity , Incidence , Male , Middle Aged , Registries , Retrospective Studies , Risk Assessment , Risk Factors , ST Elevation Myocardial Infarction/diagnosis , Temperature , Time Factors
16.
Catheter Cardiovasc Interv ; 94(2): 216-222, 2019 Aug 01.
Article in English | MEDLINE | ID: mdl-30719828

ABSTRACT

OBJECTIVES: The aim of this study was to determine the accuracy of DoseMap™ software as compared to gafchromic film in real clinical practices. BACKGROUND: The radiation exposure from cardiovascular procedures could expose patients to potential risk of cancer and/or skin injury. New tools like Dosemap software were developed to estimate the patient skin dose in the cardiac catheterization laboratory. However, little data are available to validate this estimation of patient radiation skin dose. METHODS: This is a prospective cross-sectional study comparing the peak skin dose (PSD) measured by gafchromic film used as reference with an estimated PSD given by Dosemap software, in patients with BMI > 30 kg/m2 undergoing elective diagnostic and/or therapeutic interventional cardiology procedures, from April 2016 to December 2016, at the Brest University Hospital Centre, France. RESULTS: After four exclusions of patients for poor quality of gafchromic films, 90 patients were included, with 58 angiography (67.4%), 14 percutaneous interventions (16.3%), and 14 both (16.3%). The median PSDDosemap and PSDFilm were similar with 157 mGy [IQR: 99; 273] versus 158 mGy [IQR: 101; 295] (P = 0.65), respectively, with an excellent correlation (r = 0.95). The comparison between cumulative air kerma and PSDFilm was different 366 mGy [IQR: 246; 575] versus 158 mGy [IQR: 101; 295] (P < 0.01) with moderate correlation (r = 0.79). No correlation was found between the dose area product and PSDFilm (r = 0.51). CONCLUSION: DoseMap is an effective and valid method as compared to gafchromic films to estimate PSDs during interventional cardiologic procedures.


Subject(s)
Cardiac Catheterization , Coronary Angiography , Percutaneous Coronary Intervention , Radiation Dosage , Radiation Exposure , Radiation Monitoring/methods , Radiography, Interventional , Skin/radiation effects , Software Validation , Cardiac Catheterization/adverse effects , Coronary Angiography/adverse effects , Cross-Sectional Studies , Female , Film Dosimetry , Humans , Male , Patient Safety , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Radiation Exposure/adverse effects , Radiation Monitoring/instrumentation , Radiography, Interventional/adverse effects , Reproducibility of Results , Risk Assessment , Risk Factors
17.
Arch Cardiovasc Dis ; 112(4): 234-240, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30639198

ABSTRACT

BACKGROUND: France has a long history of successful cardiovascular research and scientific innovations, but its continued success cannot be taken for granted. AIMS: To identify current obstacles to cardiovascular research in France and to crystallize the analysis into recommendations for maintained and enhanced research excellence in the future. METHODS: The French Society of Cardiology set up seven Working Groups, each comprising four to eight cardiologists, covering a spectrum of research institutes, hospitals, specialties, ages and research experience. The Working Groups met regularly in person or by conference call to analyse experiences, refine situation assessments and formulate recommendations for improvements. Results and suggestions were presented to a Core Team, which worked to synthesize, prioritize and organize the findings into a consolidated situation assessment and generate a set of action-orientated recommendations. RESULTS: Four key areas of action were identified: stronger focus on the generation of high-quality data; facilitation of future cardiovascular research; greater promotion and support for research among young cardiologists; and increased focus and support for communications. Most recommendations targeted structural shortcomings and may be implemented at low additional financial cost. CONCLUSIONS: It is possible to maintain, and even increase, the quality of cardiovascular research in France and to boost the conversion of successful projects into high-impact publications, without major increases in funding. Intense collaboration between specialties and organizations is necessary to achieve sustainable results.


Subject(s)
Biomedical Research/standards , Cardiology/standards , Cardiovascular Diseases , Periodicals as Topic/standards , Quality Control , Research Design/standards , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/physiopathology , Cardiovascular Diseases/therapy , Consensus , Cooperative Behavior , Diffusion of Innovation , Forecasting , France , Humans , Interdisciplinary Communication
19.
JAMA Cardiol ; 4(1): 64-70, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30566185

ABSTRACT

Importance: In low-flow, low-gradient aortic stenosis (LFLG AS), the severity of left ventricular dysfunction remains a key factor in the evaluation of aortic valve replacement. Objective: To evaluate the clinical outcomes and changes in left ventricular ejection fraction (LVEF) after transcatheter aortic valve replacement (TAVR) in patients with LFLG AS and severe left ventricular dysfunction. Design, Setting, and Participants: This multicenter registry is a substudy of the True or Pseudo-Severe Aortic Stenosis-TAVI registry that included patients with classic LFLG AS, defined as a mean transvalvular gradient less than 35 mm Hg, an effective orifice area less than 1.0 cm2, and an LVEF of 40% or less. Patients were divided in groups with very low (<30%) LVEF and low (30%-40%) LVEF. Dobutamine stress echocardiography (DSE) was performed before TAVR in a subset with very low LVEF, and presence of contractile reserve was defined as an increase of 20% or more in stroke volume. Clinical outcomes were assessed at 1 and 12 months and yearly thereafter, and echocardiography was performed at 1-year follow-up. Retrospective data were collected from 2007 to 2013 and prospective data from January 2013 to March 2018. Data were analyzed from March to October 2018. Exposures: Transcatheter aortic valve replacement in patients with LFLG AS. Main Outcomes and Measures: Changes in LVEF over time; periprocedural and late mortality. Results: A total of 293 patients were included, including 128 (43.7%) with very low LVEF and 165 with low LVEF (56.3%). Their mean (SD) age was 80 (7) years, and most (214 [73.0%]) were men. The mean (SD) LVEF in the very low LVEF group was 22% (5%), compared with 37% (7%) in the low LVEF group (P < .001). There were no differences between groups in rates of periprocedural mortality and late mortality (median [interquartile range], 23 [6-38] months). Patients with very low LVEF displayed a greater increase in LVEF at the 1-year follow-up examination (mean absolute increase, 11.9% [95% CI, 8.8%-15.1%]), than the low LVEF group (3.6% [95% CI, 1.1%-6.1%]; P < .001). In 92 patients with very low LVEF who had preprocedural DSE, results showed a lack of contractile reserve in 45 (49%), but this had no effect on clinical outcomes or changes in LVEF over time. Conclusions and Relevance: In patients with LFLG AS and severe left ventricular dysfunction, TAVR was associated with similar clinical outcomes as in counterparts with milder left ventricular dysfunction. The TAVR procedure was associated with a significant increase in LVEF, irrespective of contractile reserve. These results support TAVR for LFLG AS, irrespective of the severity of left ventricular dysfunction and DSE results.


Subject(s)
Aortic Valve Stenosis/surgery , Stroke Volume/physiology , Transcatheter Aortic Valve Replacement/adverse effects , Ventricular Function, Left/physiology , Aged , Aged, 80 and over , Echocardiography, Stress/methods , Female , Humans , Male , Outcome Assessment, Health Care , Prospective Studies , Registries , Retrospective Studies , Severity of Illness Index , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology
20.
Open Heart ; 5(2): e000869, 2018.
Article in English | MEDLINE | ID: mdl-30364562

ABSTRACT

Objective: The aim of this study was to compare the prevalence of left ventricle non-compaction (LVNC) criteria (or hypertrabeculation) in a cohort of patients with bicuspid aortic valve (BAV) and healthy control subjects (CTL) without cardiovascular disease using cardiovascular MR (CMR). Methods: 79 patients with BAV and 85 CTL with tricuspid aortic valve and free of known cardiovascular disease underwent CMR to evaluate the presence of LVNC criteria. The left ventricle was assessed at end-systole and end-diastole, in the short-axis, two-chamber and four-chamber views and divided into the 16 standardised myocardial segments. LVNC was assessed using the non-compacted/compacted (NC/C) myocardium ratio and was considered to be present if at least one of the myocardial segments had a NC/C ratio superior to the cut-off values defined in previous studies: Jenni et al (>2.0 end-systole); Petersen et al (>2.3 end-diastole); or Fazio et al (>2.5 end-diastole). Results: 15 CTL (17.6%) vs 8 BAV (10.1%) fulfilled Jenni et al's criterion; 69 CTL (81.2%) vs 49 BAV (62.0%) fulfilled Petersen et al's criterion; and 66 CTL (77.6%) vs 43 BAV (54.4%) fulfilled Fazio et al's criterion. Petersen et al and Fazio et al's LVNC criteria were met more often by CTL (p=0.006 and p=0.002, respectively) than patients with BAV, whereas this difference was not statistically significant according to Jenni et al's criterion (p=0.17). In multivariable analyses, after adjusting for age, sex, the presence of significant valve dysfunction (>mild stenosis or >mild regurgitation), indexed LV mass, indexed LV end-diastolic volume and LV ejection fraction, BAV was not associated with any of the three LVNC criteria. Conclusion: Patients with BAV do not harbour more LVNC than the general population and there is no evidence that they are at higher risk for the development of LVNC cardiomyopathy.

SELECTION OF CITATIONS
SEARCH DETAIL
...