Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Breast J ; 26(7): 1289-1295, 2020 07.
Article in English | MEDLINE | ID: mdl-32108973

ABSTRACT

OBJECTIVE OR PURPOSE OF STUDY: The objective of this retrospective study was to determine the frequency of positive findings on breast magnetic resonance imaging (MRI) in patients with palpable breast abnormalities in the setting of negative mammographic and sonographic evaluations. MATERIALS, METHODS, AND PROCEDURES: Consecutive patients undergoing breast MRI for palpable abnormalities from January 1, 2005 to December 31, 2015 were identified for this retrospective study. Those with preceding imaging (mammograms or ultrasounds) demonstrating positive findings related to the palpable abnormalities were excluded. The location and the duration of the symptoms, the type and the location of the abnormal MRI findings, and their relationships to the symptoms were recorded. Clinical and imaging follow-up as well as the type and the resultant biopsies were recorded. Patients with less than two years of imaging or clinical follow-up were excluded from the study. RESULTS: 22 004 women presented with palpable abnormalities at one breast imaging center between January 1, 2005 and December 31, 2015. Nine thousand and three hundred and thirty-four patients had negative or benign findings on mammography, ultrasound, or mammography plus ultrasound. Thirty-one patients underwent MRI with the complaint of palpable abnormalities despite negative or benign mammographic and/or sonographic findings. Their age range was between 32 and 74 years, and their mean age was 49 years. Of those who had MRI, twenty-one patients had negative MRI findings. Six patients had negative concordant results for the palpable abnormalities and benign incidental findings. Three patients had benign concordant results for the palpable abnormalities, and one patient had incidental atypia. Twenty-eight patients had negative MRI results in the area of the palpable abnormality, and none of these patients underwent biopsy. Of the 31 cases, four patients (13%) underwent additional examinations (three second-look ultrasounds and one bone scan) after MRI. Five patients (16%) underwent MRI-guided biopsies, two patients (6%) underwent ultrasound-guided biopsies, and one patient (3%) had an excision. All biopsies showed benign results. The Gail risk score was calculated for 22 of them and the mean 5-year risk was 1.64 and the mean lifetime risk was 12.51. CONCLUSION: Breast MRI to evaluate palpable abnormalities after negative mammography and ultrasound results in a low yield for malignancy. The majority of patients (67.7%) had negative MRI examinations, and there were no malignancies detected. Our findings lead us to believe that there are no data to encourage the use of MRI in patients with palpable abnormalities and negative mammographic and/or ultrasound studies.


Subject(s)
Breast Diseases , Breast Neoplasms , Adult , Aged , Breast Neoplasms/diagnostic imaging , Female , Humans , Magnetic Resonance Imaging , Mammography , Middle Aged , Retrospective Studies , Ultrasonography, Mammary
2.
Eur J Breast Health ; 15(4): 229-234, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31620681

ABSTRACT

OBJECTIVE: To evaluate the association between retrospective peer review of breast magnetic resonance imaging-guided vacuum-assisted needle biopsies and positive predictive value of subsequent magnetic resonance imaging-guided biopsies. MATERIALS AND METHODS: In January, 2015, a weekly conference was initiated in our institution to evaluate all breast magnetic resonance imaging-guided vacuum-assisted needle biopsies performed over January 1, 2014-December 31, 2015. During this weekly conferences, breast dynamic contrast-enhanced magnetic resonance imaging findings of 6 anonymized cases were discussed and then the faculty voted on whether they agree with the biopsy indication, accurate sampling and radiology-pathology correlation. We retrospectively reviewed and compared the magnetic resonance imaging indication, benign or malignant pathology rates, lesion types and the positive predictive value of magnetic resonance imaging-guided vacuum-assisted needle biopsy in the years before and after initiating this group peer review. RESULTS: The number of dynamic contrast-enhanced magnetic resonance imaging and magnetic resonance imaging-guided vacuum-assisted needle biopsies before and after initiating the review were 1447 vs 1596 (p=0.0002), and 253 (17.5%) vs 203 (12.7%) (p=0.04), respectively. There was a significant decrease in the number of benign biopsies in 2015 (n=104) compared to 2014 (n=154, p=0.04). The positive predictive value of magnetic resonance imaging-guided biopsy significantly increased after group review was implemented (Positive predictive value in 2014=%39.1 and positive predictive value in 2015=%48.8) (p=0.03), although the indications (p=0.49), history of breast cancer (p=0.14), biopsied magnetic resonance imaging lesion types (p=0.53) were not different. Less surgical excision was performed on magnetic resonance imaging-guided vacuum-assisted needle biopsy identified high-risk lesions in 2015 (p=0.25). CONCLUSION: Our study showed an association between retrospective peer review of past biopsies and increased positive predictive value of magnetic resonance imaging-guided vacuum-assisted needle biopsies in our institution.

3.
Ann Surg Oncol ; 23(8): 2438-45, 2016 08.
Article in English | MEDLINE | ID: mdl-27221361

ABSTRACT

BACKGROUND: Cryoablation is a well-established technique to treat fibroadenomas. Pilot studies suggest this could be an effective non-surgical treatment for breast cancer. American College of Surgeons Oncology Group Z1072 is a phase II trial exploring the effectiveness of cryoablation in the treatment of breast cancers. METHODS: The primary endpoint of Z1072 was the rate of complete tumor ablation, defined as no remaining invasive breast cancer (IBC) or ductal carcinoma in situ (DCIS) on pathologic examination of the targeted lesion. A secondary objective was to evaluate the negative predictive value of magnetic resonance imaging (MRI) to determine residual IBC or DCIS. Eligible patients included those with unifocal invasive ductal breast cancer ≤2 cm, with <25 % intraductal component and tumor enhancement on MRI. A total of 19 centers contributed 99 patients, of which 86 patients (87 breast cancers) were evaluable for data analysis. RESULTS: Final pathology results, regardless of whether residual IBC/DCIS was in the targeted ablation zone or elsewhere in the breast, showed successful ablation in 66/87 (75.9 %) cancers. The 90 % confidence interval for the estimate of successful cryoablation was 67.1-83.2, with the one-sided lower-sided 90 % CI of 69.0. The negative predictive value of MRI was 81.2 % (90 % CI 71.4-88.8). When multifocal disease outside of the targeted cryoablation zone was not defined as an ablation failure, 80/87 (92 %) of the treated cancers had a successful cryoablation. CONCLUSION: Further studies with modifications on the Z1072 protocol could be considered to evaluate the role for cryoablation as a non-surgical treatment of early-stage breast cancer.


Subject(s)
Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/surgery , Cryosurgery/methods , Adult , Aged , Aged, 80 and over , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Ductal, Breast/pathology , Female , Humans , Magnetic Resonance Imaging , Middle Aged , Neoplasm Invasiveness , Predictive Value of Tests , Treatment Outcome
4.
Integr Cancer Ther ; 9(4): 348-53, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21106615

ABSTRACT

UNLABELLED: The majority of patients with cancer use some form of complementary or alternative medicine. External qigong treatment (EQT), classified as a bioenergy therapy, is one such approach that patients combine with conventional medicine or, in some cases, use in place of conventional medicine. This study aimed to determine whether EQT could shrink breast cancer tumors and improve quality of life (QOL) in women with pathologically confirmed breast cancer awaiting surgery. A total of 9 women with pathologically confirmed breast cancer were recruited from large cancer centers in the United States (n = 5) and China (n = 4). A single-arm pre/post design was used. Each patient underwent 5 consecutive days of EQT, with each treatment lasting from 2 to 5 minutes. All treatments were performed by the same qigong master. Tumor measurements were made before and after the EQT sessions. Tumor assessments were conducted prior to study initiation and following the last EQT. Patients underwent both an ultrasound and mammogram (United States) or an ultrasound and magnetic resonance imaging (China). All patients also underwent physical breast examinations (PBEs) and completed QOL questionnaires before and after the last EQT. No clinical changes in tumor measurements from pre- to post-EQT were noted. There was also no suggestion of change in tumor size by PBE or change in QOL. Using the current STUDY DESIGN: EQT also does not appear to have any effect on patient QOL. Because of the small sample size and working with only one qigong practitioner, to definitively determine the efficacy or lack of efficacy of EQT, a larger study with multiple qigong practitioners would need to be conducted.


Subject(s)
Breast Neoplasms/therapy , Breathing Exercises , Carcinoma, Ductal, Breast/therapy , Mastectomy , Preoperative Period , Aged , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/surgery , Female , Humans , Mastectomy/rehabilitation , Middle Aged , Patient Satisfaction , Quality of Life , Self Report , Treatment Outcome
5.
Semin Oncol ; 35(1): 51-63, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18308146

ABSTRACT

Imaging plays several key roles in the diagnosis and assessment of inflammatory breast cancer (IBC). These include characterization of the known tumor, delineation of locoregional disease in the ipsilateral and contralateral breast and regional lymph node basins, diagnosis of distant metastases, and evaluation of treatment response. We review the role of conventional imaging modalities, including mammography and sonography. We also discuss the potential of using evolving imaging modalities such as magnetic resonance imaging (MRI), positron emission tomography with computed tomography (PET/CT), and more advanced or emerging imaging techniques in the assessment of IBC.


Subject(s)
Breast Neoplasms/diagnosis , Carcinoma/diagnosis , Diagnostic Imaging/trends , Inflammation/diagnosis , Breast Neoplasms/pathology , Carcinoma/complications , Carcinoma/pathology , Diagnostic Imaging/methods , Female , Humans , Magnetic Resonance Imaging , Mammography , Neoplasm Metastasis , Positron-Emission Tomography/methods , Ultrasonography, Mammary
SELECTION OF CITATIONS
SEARCH DETAIL
...