Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Med. intensiva (Madr., Ed. impr.) ; 39(9): 552-562, dic. 2015.
Article in Spanish | IBECS | ID: ibc-145029

ABSTRACT

Estos últimos años han aparecido alertas de seguridad, no siempre bien sustentadas, que cuestionan el uso de algunas alternativas farmacológicas a la transfusión de sangre alogénica y/o lo restringen en indicaciones establecidas. Asistimos también a la preconización de otras alternativas, incluyendo productos hemáticos y fármacos antifibrinolíticos, sin que haya una base científica sólida que lo justifique. Por iniciativa del Grupo de Estudios Multidisciplinares sobre Autotransfusión y del Anemia Working Group España se reunió a un panel multidisciplinar de 23 expertos del área de cuidados de la salud en un foro de debate para: 1) analizar las diferentes alertas de seguridad en torno a ciertas alternativas a la transfusión; 2) estudiar los antecedentes que las han propiciado, la evidencia que las sustentan y las consecuencias que conllevan para la práctica clínica, y 3) emitir una valoración argumentada de la seguridad de cada alternativa a la transfusión cuestionada, según el uso clínico de la misma. Los integrantes del foro mantuvieron contactos por vía telemática y una reunión presencial en la que presentaron y discutieron las conclusiones sobre cada uno de los elementos examinados. Se elaboró un primer documento que fue sometido a 4 rondas de revisión y actualización hasta alcanzar un consenso, unánime en la mayoría de los casos. Presentamos la versión final del documento, aprobada por todos los miembros del panel, esperando sea de utilidad para nuestros colegas


In recent years, several safety alerts have questioned or restricted the use of some pharmacological alternatives to allogeneic blood transfusion in established indications. In contrast, there seems to be a promotion of other alternatives, based on blood products and/or antifibrinolytic drugs, which lack a solid scientific basis. The Multidisciplinary Autotransfusion Study Group and the Anemia Working Group España convened a multidisciplinary panel of 23 experts belonging to different healthcare areas in a forum for debate to: 1) analyze the different safety alerts referred to certain transfusion alternatives; 2) study the background leading to such alternatives, the evidence supporting them, and their consequences for everyday clinical practice, and 3) issue a weighted statement on the safety of each questioned transfusion alternative, according to its clinical use. The members of the forum maintained telematics contact for the exchange of information and the distribution of tasks, and a joint meeting was held where the conclusions on each of the items examined were presented and discussed. A first version of the document was drafted, and subjected to 4 rounds of review and updating until consensus was reached (unanimously in most cases). We present the final version of the document, approved by all panel members, and hope it will be useful for our colleagues


Subject(s)
Humans , Blood Transfusion, Autologous/methods , Blood Transfusion/methods , Postoperative Hemorrhage/therapy , Critical Care/methods , Intensive Care Units/organization & administration , Erythropoiesis/physiology , Factor VIII/pharmacokinetics , Colloids/pharmacokinetics , Patient Safety
3.
Med. intensiva (Madr., Ed. impr.) ; 37(4): 259-283, mayo 2013. tab
Article in Spanish | IBECS | ID: ibc-114750

ABSTRACT

La transfusión de sangre alogénica (TSA) no es inocua, y como consecuencia han surgido múltiples alternativas a la misma (ATSA). Existe variabilidad respecto a las indicaciones y buen uso de las ATSA. Dependiendo de la especialidad de los médicos que tratan a los pacientes, el grado de anemia, la política transfusional, la disponibilidad de las ATSA y el criterio personal, estas se usan de forma variable. Puesto que las ATSA tampoco son inocuas y pueden no cumplir criterios de coste-efectividad, la variabilidad en su uso es inaceptable. Las sociedades españolas de Anestesiología y Reanimación (SEDAR), Hematología y Hemoterapia(SEHH), Farmacia Hospitalaria (SEFH), Medicina Intensiva y Unidades Coronarias(SEMICYUC), Trombosis y Hemostasia (SETH) y Transfusiones Sanguíneas (SETS) han elaborado un documento de consenso para el buen uso de la ATSA. Un panel de expertos de las 6sociedades ha llevado a cabo una revisión sistemática de la literatura médica y elaborado el 2013. Documento Sevilla de Consenso sobre Alternativas a la Transfusión de Sangre Alogénica. Solo se contempla las ATSA dirigidas a disminuir la transfusión de concentrado de hematíes. Se definen las ATSA como toda medida farmacológica y no farmacológica encaminada a disminuir la transfusión de concentrado de hematíes, preservando siempre la seguridad del paciente. La cuestión principal que se plantea en cada ítem se formula, en forma positiva o negativa, como: “La ATSA en cuestión reduce/no reduce la tasa transfusional». Para formular el grado de recomendación se ha usado la metodología Grades of Recommendation Assessment, Development and Evaluation (GRADE) (AU)


Since allogeneic blood transfusion (ABT) is not harmless, multiple alternatives to ABT (AABT) have emerged, though there is great variability in their indications and appropriate use. This variability results from the interaction of a number of factors, including the specialty of the physician, knowledge and preferences, the degree of anemia, transfusion policy, and AABT availability. Since AABTs are not harmless and may not meet cost-effectiveness criteria, such variability is unacceptable. The Spanish Societies of Anesthesiology (SEDAR), Hematology and Hemotherapy (SEHH), Hospital Pharmacy (SEFH), Critical Care Medicine (SEMICYUC), Thrombosis and Hemostasis (SETH)and Blood Transfusion (SETS) have developed a Consensus Document for the proper use of AABTs. A panel of experts convened by these 6 Societies have conducted a systematic review of the medical literature and have developed the 2013 Seville Consensus Document on Alternatives to Allogeneic Blood Transfusion, which only considers those AABT aimed at decreasing the transfusion of packed red cells. AABTs are defined as any pharmacological or non-pharmacological measure aimed at decreasing the transfusion of red blood cell concentrates, while preserving patient safety. For each AABT, the main question formulated, positively or negatively, is: “Does this particular AABT reduce the transfusion rate or not? “All the recommendations on the use of AABTs were formulated according to the Grades of Recommendation Assessment, Development and Evaluation(GRADE) methodology (AU)


Subject(s)
Humans , Blood Transfusion, Autologous , Blood Transfusion/methods , Blood Substitutes/therapeutic use , Anemia/therapy , Glycated Hemoglobin/therapeutic use , Fibrinogen/therapeutic use , Practice Patterns, Physicians'
4.
Rev. esp. anestesiol. reanim ; 60(5): 263e1-263e25, mayo 2013.
Article in Spanish | IBECS | ID: ibc-112548

ABSTRACT

La transfusión de sangre alogénica (TSA) no es inocua, y como consecuencia han surgido múltiples alternativas a la misma (ATSA). Existe variabilidad respecto a las indicaciones y buen uso de las ATSA. Dependiendo de la especialidad de los médicos que tratan a los pacientes, el grado de anemia, la política transfusional, la disponibilidad de las ATSA y el criterio personal, estas se usan de forma variable. Puesto que las ATSA tampoco son inocuas y pueden no cumplir criterios de coste-efectividad, la variabilidad en su uso es inaceptable. Las sociedades españolas de Anestesiología y Reanimación (SEDAR), Hematología y Hemoterapia (SEHH), Farmacia Hospitalaria (SEFH), Medicina Intensiva y Unidades Coronarias (SEMICYUC), Trombosis y Hemostasia (SETH) y Transfusiones Sanguíneas (SETS) han elaborado un documento de consenso para el buen uso de la ATSA. Un panel de expertos de las 6 sociedades ha llevado a cabo una revisión sistemática de la literatura médica y elaborado el 2013. Documento Sevilla de Consenso sobre Alternativas a la Transfusión de Sangre Alogénica. Solo se contempla las ATSA dirigidas a disminuir la transfusión de concentrado de hematíes. Se definen las ATSA como toda medida farmacológica y no farmacológica encaminada a disminuir la transfusión de concentrado de hematíes, preservando siempre la seguridad del paciente. La cuestión principal que se plantea en cada ítem se formula, en forma positiva o negativa, como: «La ATSA en cuestión reduce/no reduce la tasa transfusional». Para formular el grado de recomendación se ha usado la metodología Grades of Recommendation Assessment, Development and Evaluation (GRADE) (AU)


Since allogeneic blood transfusion (ABT) is not harmless, multiple alternatives to ABT (AABT) have emerged, though there is great variability in their indications and appropriate use. This variability results from the interaction of a number of factors, including the specialty of the physician, knowledge and preferences, the degree of anemia, transfusion policy, and AABT availability. Since AABTs are not harmless and may not meet cost-effectiveness criteria, such variability is unacceptable. The Spanish Societies of Anesthesiology (SEDAR), Hematology and Hemotherapy (SEHH), Hospital Pharmacy (SEFH), Critical Care Medicine (SEMICYUC), Thrombosis and Hemostasis (SETH) and Blood Transfusion (SETS) have developed a Consensus Document for the proper use of AABTs. A panel of experts convened by these 6 Societies have conducted a systematic review of the medical literature and have developed the 2013 Seville Consensus Document on Alternatives to Allogeneic Blood Transfusion, which only considers those AABT aimed at decreasing the transfusion of packed red cells. AABTs are defined as any pharmacological or non-pharmacological measure aimed at decreasing the transfusion of red blood cell concentrates, while preserving patient safety. For each AABT, the main question formulated, positively or negatively, is: "Does this particular AABT reduce the transfusion rate or not?" All the recommendations on the use of AABTs were formulated according to the Grades of Recommendation Assessment, Development and Evaluation (GRADE) methodology (AU)


Subject(s)
Humans , Male , Female , Transplantation, Homologous/instrumentation , Transplantation, Homologous/methods , Transplantation, Homologous , Cost-Benefit Analysis/organization & administration , Cost-Benefit Analysis/standards , Cost-Benefit Analysis , Evaluation of the Efficacy-Effectiveness of Interventions , Anesthesiology/methods , Transplantation, Homologous/standards , Transplantation, Homologous/trends , 50303 , Anesthesiology/organization & administration , Anesthesiology/standards , Erythrocyte Transfusion/trends , Erythrocyte Transfusion
SELECTION OF CITATIONS
SEARCH DETAIL
...