1.
Acad Radiol ; 12(2): 202-9, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15721597

ABSTRACT

RATIONALE AND OBJECTIVE: To assess the feasibility of combining magnetic resonance (MR) perfusion, angiography, and 3He ventilation imaging for the evaluation of lung function in a porcine model. MATERIALS AND METHODS: Fourteen consecutive porcine models with externally delivered pulmonary emboli and/or airway occlusions were examined with MR perfusion, angiography, and 3He ventilation imaging. Ultrafast gradient-echo sequences were used for 3D perfusion and angiographic imaging, in conjunction with the use of contrast-agent injections. 2D multiple-section 3He imaging was performed subsequently via the inhalation of hyperpolarized 3He gas. The diagnostic accuracy of MR angiography for detecting pulmonary emboli was determined by two reviewers. The diagnostic confidence for different combinations of MR techniques was rated on the basis of a 5-point grading scale (5 = definite). RESULTS: The sensitivity, specificity, and accuracy of MR angiography for detecting pulmonary emboli were approximately 85.7%, 90.5%, and 88.1%, respectively. The interobserver agreement was very strong (k = 0.82). There was a clear tendency for confidence to increase when first perfusion and then ventilation imaging were added to the angiographic image (Wilcoxon signed ranks test, P = 0.03). CONCLUSION: The combination of the three methods of MR perfusion, angiography, and 3H ventilation imaging may provide complementary information on abnormal lung anatomy and function.


Subject(s)
Airway Obstruction/diagnosis , Disease Models, Animal , Helium , Magnetic Resonance Angiography/methods , Magnetic Resonance Imaging/methods , Pulmonary Embolism/diagnosis , Administration, Inhalation , Animals , Contrast Media/administration & dosage , Feasibility Studies , Gadolinium DTPA , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Isotopes , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Swine
2.
J Magn Reson ; 169(2): 196-202, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15261614

ABSTRACT

It has been demonstrated previously that the surface-to-volume ratio S/V can be determined from the derivative of the time-dependent diffusion coefficient D(t), in the limit t --> 0. Several questions arise concerning the practicality of determining S/V by NMR. In particular, how large are the errors generated by (1) working outside the t --> 0 limit and (2) measuring D outside the b --> 0 limit, both for narrow and full-width gradient pulses? Here b is gamma2G2delta2Delta for narrow pulses and gamma2G2t3/12 for broad pulses. These questions are addressed by random-walk computer simulations and numerical calculations in geometries relevant to small-airways of lung. The results demonstrate that one can work well outside the t --> 0 and b --> 0 limits, provided 10-20% accuracy in the measured S/V is sufficient. Emphasis is placed on the useful range of times t for which NMR determinations of lung S/V are feasible.


Subject(s)
Computer Simulation , Diffusion Magnetic Resonance Imaging/methods , Models, Biological , Algorithms , Diffusion , Feasibility Studies , Humans , Magnetic Resonance Spectroscopy , Pulmonary Alveoli/metabolism , Pulmonary Diffusing Capacity/physiology , Time Factors
3.
Magn Reson Med ; 47(3): 433-8, 2002 Mar.
Article in English | MEDLINE | ID: mdl-11870828

ABSTRACT

Three-dimensional (3D) perfusion imaging allows the assessment of pulmonary blood flow in parenchyma and main pulmonary arteries simultaneously. MRI using laser-polarized (3)He gas clearly shows the ventilation distribution with high signal-to-noise ratio (SNR). In this report, the feasibility of combined lung MR angiography, perfusion, and ventilation imaging is demonstrated in a porcine model. Ultrafast gradient-echo sequences have been used for 3D perfusion and angiographic imaging, in conjunction with the use of contrast agent injections. 2D multiple-section (3)He imaging was performed subsequently by inhalation of 450 ml of hyperpolarized (3)He gas. The MR techniques were examined in a series of porcine models with externally delivered pulmonary emboli and/or airway occlusions. With emboli, perfusion deficits without ventilation defects were observed; airway occlusion resulted in matched deficits in perfusion and ventilation. High-resolution MR angiography can unambiguously reveal the location and size of the blood emboli. The combination of the three imaging methods may provide complementary information on abnormal lung anatomy and function.


Subject(s)
Airway Obstruction/diagnosis , Magnetic Resonance Imaging/methods , Pulmonary Embolism/diagnosis , Animals , Feasibility Studies , Helium/pharmacokinetics , Imaging, Three-Dimensional , Isotopes , Magnetic Resonance Angiography , Pulmonary Ventilation/physiology , Swine , Ventilation-Perfusion Ratio
4.
Proc Natl Acad Sci U S A ; 99(5): 3111-6, 2002 Mar 05.
Article in English | MEDLINE | ID: mdl-11867733

ABSTRACT

The study of lung emphysema dates back to the beginning of the 17th century. Nevertheless, a number of important questions remain unanswered because a quantitative localized characterization of emphysema requires knowledge of lung structure at the alveolar level in the intact living lung. This information is not available from traditional imaging modalities and pulmonary function tests. Herein, we report the first in vivo measurements of lung geometrical parameters at the alveolar level obtained with 3He diffusion MRI in healthy human subjects and patients with severe emphysema. We also provide the first experimental data demonstrating that 3He gas diffusivity in the acinus of human lung is highly anisotropic. A theory of anisotropic diffusion is presented. Our results clearly demonstrate substantial differences between healthy and emphysematous lung at the acinar level and may provide new insights into emphysema progression. The technique offers promise as a clinical tool for early diagnosis of emphysema.


Subject(s)
Emphysema/diagnostic imaging , Lung/diagnostic imaging , Diffusion , Emphysema/diagnosis , Emphysema/physiopathology , Helium , Humans , Lung/physiopathology , Magnetic Resonance Imaging/methods , Models, Anatomic , Radiography