Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Phys ; 17(12): 1396-1401, 2021.
Article in English | MEDLINE | ID: mdl-34966439

ABSTRACT

Ultralight bosons such as axion-like particles are viable candidates for dark matter. They can form stable, macroscopic field configurations in the form of topological defects that could concentrate the dark matter density into many distinct, compact spatial regions that are small compared with the Galaxy but much larger than the Earth. Here we report the results of the search for transient signals from the domain walls of axion-like particles by using the global network of optical magnetometers for exotic (GNOME) physics searches. We search the data, consisting of correlated measurements from optical atomic magnetometers located in laboratories all over the world, for patterns of signals propagating through the network consistent with domain walls. The analysis of these data from a continuous month-long operation of GNOME finds no statistically significant signals, thus placing experimental constraints on such dark matter scenarios.

2.
Sensors (Basel) ; 21(4)2021 Feb 09.
Article in English | MEDLINE | ID: mdl-33572285

ABSTRACT

Magnetic nanoparticles (MNP) offer a large variety of promising applications in medicine thanks to their exciting physical properties, e.g., magnetic hyperthermia and magnetic drug targeting. For these applications, it is crucial to quantify the amount of MNP in their specific binding state. This information can be obtained by means of magnetorelaxometry (MRX), where the relaxation of previously aligned magnetic moments of MNP is measured. Current MRX with optically pumped magnetometers (OPM) is limited by OPM recovery time after the shut-off of the external magnetic field for MNP alignment, therewith preventing the detection of fast relaxing MNP. We present a setup for OPM-MRX measurements using a commercially available pulsed free-precession OPM, where the use of a high power pulsed pump laser in the sensor enables a system recovery time in the microsecond range. Besides, magnetometer raw data processing techniques for Larmor frequency analysis are proposed and compared in this paper. Due to the high bandwidth (≥100 kHz) and high dynamic range of our OPM, a software gradiometer in a compact enclosure allows for unshielded MRX measurements in a laboratory environment. When operated in the MRX mode with non-optimal pumping performance, the OPM shows an unshielded gradiometric noise floor of about 600 fT/cm/Hz for a 2.3 cm baseline. The noise floor is flat up to 1 kHz and increases then linearly with the frequency. We demonstrate that quantitative unshielded MRX measurements of fast relaxing, water suspended MNP is possible with the novel OPM-MRX concept, confirmed by the accurately derived iron amount ratios of MNP samples. The detection limit of the current setup is about 1.37 µg of iron for a liquid BNF-MNP-sample (Bionized NanoFerrite) with a volume of 100 µL.


Subject(s)
Magnetite Nanoparticles , Magnetic Fields , Magnetics , Software
3.
IEEE Trans Med Imaging ; 39(4): 922-933, 2020 04.
Article in English | MEDLINE | ID: mdl-31478841

ABSTRACT

We introduce a Magnetic Particle Imaging Susceptometer (MPIS) that uses a high-sensitivity atomic magnetometer (AM) for recording the spatial distribution of fluid-suspended magnetic nanoparticles. We have evaluated the MPIS performance by one-dimensional scans of structured nanoparticle phantoms, demonstrating, in particular, resolutions of ≈2.5 mm prior to deconvolution and << 1 mm after deconvolution. Our instrument conceptually follows the general principle of Magnetic Particle Imaging (MPI) for encoding spatial distributions into magnetic flux density variations. Conversely to previously demonstrated MPI methods, MPIS works in time-space by recording time series of the sample's magnetic response including all Fourier components. The device deploys a specifically designed system of coils, a low-frequency excitation scheme, and a simple source localization algorithm. The difference of the AM's frequency response with respect to the conventional receive coil detection allows us to work at much lower driving frequencies. We demonstrate operation at frequencies on the order of 100 Hz, enabling the beneficial use of larger nanoparticles. The spatial distribution encoded into the particles' susceptibility needs a much lower excitation field amplitude compared to conventional MPI scanners. These two features make MPIS least harmful for biological samples and subjects compared to conventional MPI scanners. We also address performance characteristics and other possible applications of MPIS.


Subject(s)
Diagnostic Imaging/methods , Magnetite Nanoparticles/chemistry , Magnetometry/methods , Algorithms , Equipment Design , Phantoms, Imaging
4.
Biochim Biophys Acta Bioenerg ; 1860(2): 121-128, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30465750

ABSTRACT

Cyanobacteria are thought to be responsible for pioneering dioxygen production and the so-called "Great Oxygenation Event" that determined the formation of the ozone layer and the ionosphere restricting ionizing radiation levels reaching our planet, which increased biological diversity but also abolished the necessity of radioprotection. We speculated that ancient protection mechanisms could still be present in cyanobacteria and studied the effect of ionizing radiation and space flight during the Foton-M4 mission on Synechocystis sp. PCC6803. Spectral and functional characteristics of photosynthetic membranes revealed numerous similarities of the effects of α-particles and space flight, which both interrupted excitation energy transfer from phycobilisomes to the photosystems and significantly reduced the concentration of phycobiliproteins. Although photosynthetic activity was severely suppressed, the effect was reversible, and the cells could rapidly recover from the stress. We suggest that the actual existence and the uncoupling of phycobilisomes may play a specific role not only in photo-, but also in radioprotection, which could be crucial for the early evolution of Life on Earth.


Subject(s)
Cyanobacteria/chemistry , Energy Transfer , Phycobilisomes/physiology , Radiation-Protective Agents/chemistry , Origin of Life , Photosynthesis , Phycobiliproteins/physiology , Radiation, Ionizing , Space Flight
5.
Chem Commun (Camb) ; 51(91): 16421, 2015 Nov 25.
Article in English | MEDLINE | ID: mdl-26499838

ABSTRACT

Correction for 'Coordination-directed self-assembly of a simple benzothiadiazole-fused tetrathiafulvalene to low-bandgap metallogels' by Anneliese M. Amacher et al., Chem. Commun., 2015, 51, 15063-15066.

6.
Chem Commun (Camb) ; 51(81): 15063-6, 2015 Oct 18.
Article in English | MEDLINE | ID: mdl-26314376

ABSTRACT

Coordination-driven gelation of a benzothiadiazole-fused tetrathiafulvalene (TTF) is demonstrated. This is the first work reporting highly stable metallogels based on a donor-acceptor conjugate with such a simple structure for the construction of new low-bandgap materials with various functional properties and novel nanostructures.


Subject(s)
Coordination Complexes/chemical synthesis , Heterocyclic Compounds/chemistry , Nanostructures/chemistry , Thiadiazoles/chemistry , Coordination Complexes/chemistry , Gels/chemical synthesis , Gels/chemistry , Molecular Structure
7.
Nat Commun ; 4: 2435, 2013.
Article in English | MEDLINE | ID: mdl-24022336

ABSTRACT

Understanding the compatibility between spider silk and conducting materials is essential to advance the use of spider silk in electronic applications. Spider silk is tough, but becomes soft when exposed to water. Here we report a strong affinity of amine-functionalised multi-walled carbon nanotubes for spider silk, with coating assisted by a water and mechanical shear method. The nanotubes adhere uniformly and bond to the silk fibre surface to produce tough, custom-shaped, flexible and electrically conducting fibres after drying and contraction. The conductivity of coated silk fibres is reversibly sensitive to strain and humidity, leading to proof-of-concept sensor and actuator demonstrations.


Subject(s)
Nanotubes, Carbon/chemistry , Silk/chemistry , Spiders/chemistry , Tissue Scaffolds/chemistry , Animals , Electric Conductivity , Electrodes , Nanotubes, Carbon/ultrastructure , Spectroscopy, Fourier Transform Infrared , Spectrum Analysis, Raman , Stress, Mechanical , Temperature , Tensile Strength , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...