Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38180346

ABSTRACT

In this paper, we present the design and commissioning results of the upgraded collective Thomson scattering diagnostic at the Wendelstein 7-X stellarator. The diagnostic has a new radiometer designed to operate between the second and third harmonics of the electron cyclotron emission from the plasma at 171-177 GHz, where the emission background has a minimum and is of order 10-100 eV. It allows us to receive the scattered electromagnetic field with a significantly improved signal-to-noise ratio and extends the set of possible scattering geometries compared to the case of the original instrument operated at 140 GHz. The elements of the diagnostic are a narrowband notch filter and a frequency stabilized probing gyrotron that will allow measuring scattered radiation spectra very close to the probing frequency. Here, we characterize the microwave components applied to the radiometer and demonstrate the performance of the complete system that was achieved during the latest experimental campaign, OP2.1.

2.
Rev Sci Instrum ; 90(1): 013503, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30709181

ABSTRACT

A Collective Thomson Scattering (CTS) diagnostic is installed at Wendelstein 7-X for ion temperature measurements in the plasma core. The diagnostic utilizes 140 GHz gyrotrons usually used for electron cyclotron resonance heating (ECRH) as a source of probing radiation. The CTS diagnostic uses a quasi-optical transmission line covering a distance of over 40 m. The transmission line is shared between the ECRH system and the CTS diagnostic. Here we elaborate on the design, installation, and alignment of the CTS diagnostic and present the first measurements at Wendelstein 7-X.

3.
Rev Sci Instrum ; 89(10): 10H115, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399932

ABSTRACT

A passive phased array Doppler reflectometry system has recently been installed in the Wendelstein-7X stellarator. In contrast to conventional Doppler reflectometry systems, the microwave beam can be steered on short time scales in the measurement plane perpendicular to the magnetic field in the range of ±25° without mechanical steering components. This paper characterizes the design and properties of the phased array antenna system and presents the first measurement results from the latest OP1.2a campaign.

SELECTION OF CITATIONS
SEARCH DETAIL
...