Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
SAR QSAR Environ Res ; 24(8): 661-78, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23724974

ABSTRACT

Many in silico alternatives to aquatic toxicity tests rely on hydrophobicity-based quantitative structure-activity relationships (QSARs). Hydrophobicity is often estimated as log P, where P is the octanol-water partition coefficient. Immobilised artificial membrane (IAM) high performance liquid chromatography (HPLC) may be a more biologically relevant alternative to log P. The aim of this study was to investigate the applicability of a theoretical structural fragment and feature-based method to predict log k IAM (the logarithm of the retention index determined by IAM-HPLC) values. This will allow the prediction of log k IAM based on chemical structure alone. The use of structural fragment values to predict log P was first proposed in the 1970s. The application of a similar method using fragment values to predict log k IAM is a novel approach. Values of log k IAM were determined for 22 aliphatic and 42 aromatic compounds using an optimised and robust IAM-HPLC assay. The method developed shows good predictive performance using leave-one-out cross validation and application to an external validation set not seen a priori by the training set also generated good predictive values. The ability to predict log k IAM without the need for practical measurement will allow for the increased use of QSARs based on this descriptor.


Subject(s)
Chromatography, High Pressure Liquid , Membranes, Artificial , Organic Chemicals/chemistry , Hydrophobic and Hydrophilic Interactions , Molecular Structure , Quantitative Structure-Activity Relationship
2.
Environ Toxicol Chem ; 30(12): 2701-8, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21919042

ABSTRACT

A database was collated of published experimental logarithmic values for the relative retention factors (log k(IAM)) measured using an immobilized artificial membrane column and high-performance liquid chromatography (IAM HPLC). Log k(IAM) is an alternative measure of hydrophobicity to the octanol/water partition coefficient (log K(OW)). While there are several accepted methods to measure log K(OW), no standardized method exists to determine log k(IAM). The database of collated log k(IAM) values includes 13 key experimental parameters and contains 1,686 values for 555 compounds, which are predominantly polar organic compounds and include drug molecules and surfactants. These compounds are acidic, basic, and neutral and both ionized and un-ionized under the conditions of analysis. The data compiled demonstrated experimental variability for each experimental parameter considered, including column stationary phase, pH, temperature, and mobile phase. Reducing the experimental variability allowed for greater consistency in the datasets.


Subject(s)
Databases, Factual , Environmental Pollutants/chemistry , Membranes, Artificial , Pharmaceutical Preparations/chemistry , Chromatography, High Pressure Liquid/methods , Environmental Monitoring , Environmental Pollutants/analysis , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Octanols/chemistry , Pharmaceutical Preparations/analysis , Waste Disposal, Fluid , Water/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...