1.
J Med Imaging (Bellingham) ; 5(3): 033504, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30840723

ABSTRACT

Development of advanced preclinical imaging techniques has had an important impact on the field of biomedical research, with positron emission tomography (PET) imaging the most mature of these efforts. Developers of preclinical PET scanners have joined the recent multimodality imaging trend by combining PET imaging with other modalities, such as magnetic resonance imaging (MRI). Our group has developed a combined PET-MRI insert for the imaging of animals up to the size of rats in a clinical 3T MRI scanner. The system utilizes a sequential scanner configuration instead of the more common coplanar geometry. The PET component of the system consists of a ring of 12 liquid-cooled, SiPM-based detector modules ( diameter = 15.2 cm ). System performance was evaluated with the NEMA NU 4-2008 protocol. Spatial resolution is ∼ 1.71 mm 5 cm from the center of the field-of-view measured from single-slice rebinned filtered backprojection-reconstructed images. Peak noise equivalent count rate is 17.7 kcps at 8.5 MBq; peak sensitivity is 2.9%. The MRI component of the system is composed of a 12-cm-diameter birdcage transmit/receive coil with a dual-preamplifier interface possessing very low noise preamplifiers. System performance was evaluated using American College of Radiology-based methods. Image homogeneity is 99%; the ghosting ratio is 0.0054. The signal-to-noise ratio is 95 and spatial resolution is ∼ 0.25 mm . There was no discernable cross-modality interference.

2.
Magn Reson Med ; 52(3): 628-39, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15334584

ABSTRACT

Theoretical arguments and experimental results are presented that characterize the impact of inductive coupling on the performance of parallel MRI reconstructions. A simple model of MR signal and noise reception suggests that the intrinsic amount of spatial information available from a given coil array is unchanged in the presence of inductive coupling, as long as the sample remains the dominant source of noise for the coupled array. Any loss of distinctness in the measured coil sensitivities is compensated by information stored in the measured noise correlations. Adjustments to the theory are described to account for preamplifier noise contributions. Results are presented from an experimental system in which preamplifier input impedances are systematically adjusted in order to vary the level of coupling between array elements. Parallel image reconstructions using an array with four different levels of coupling and an acceleration factor up to six show average SNR changes of -7.6% to +7.5%. The modest changes in overall SNR are accompanied by similarly small changes in g-factor. These initial results suggest that moderate amounts of inductive coupling should not have a prohibitive effect on the use of a given coil array for parallel MRI.


Subject(s)
Image Processing, Computer-Assisted/instrumentation , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging
3.
Magn Reson Med ; 52(1): 131-40, 2004 Jul.
Article in English | MEDLINE | ID: mdl-15236376

ABSTRACT

A variety of continuous and pulsed arterial spin labeling (ASL) perfusion MRI techniques have been demonstrated in recent years. One of the reasons these methods are still not routinely used is the limited extent of the imaging region. Of the ASL methods proposed to date, continuous ASL (CASL) with a separate labeling coil is particularly attractive for whole-brain studies at high fields. This approach can provide an increased signal-to-noise ratio (SNR) in perfusion images because there are no magnetization transfer (MT) effects, and lessen concerns regarding RF power deposition at high field because it uses a local labeling coil. In this work, we demonstrate CASL whole-brain quantitative perfusion imaging at 3.0 T using a combination of strategies: 3D volume acquisition, background tissue signal suppression, and a separate labeling coil. The results show that this approach can be used to acquire perfusion images in all brain regions with good sensitivity. Further, it is shown that the method can be performed safely on humans without exceeding the current RF power deposition limits. The current method can be extended to higher fields, and further improved by the use of multiple receiver coils and parallel imaging techniques to reduce scan time or provide increased resolution.


Subject(s)
Cerebrovascular Circulation , Imaging, Three-Dimensional , Magnetic Resonance Imaging/methods , Humans , Magnetic Resonance Imaging/instrumentation , Spin Labels
4.
Magn Reson Med ; 51(1): 22-6, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14705041

ABSTRACT

The performance of a 16-channel receive-only RF coil for brain imaging at 3.0 Tesla was investigated using a custom-built 16-channel receiver. Both the image signal-to-noise ratio (SNR) and the noise amplification (g-factor) in sensitivity-encoding (SENSE) parallel imaging applications were quantitatively evaluated. Furthermore, the performance was compared with that of hypothetical coils with one, two, four, and eight elements (n) by combining channels in software during image reconstruction. As expected, both the g-factor and SNR improved substantially with n. Compared to an equivalent (simulated) single-element coil, the 16-channel coil showed a 1.87-fold average increase in brain SNR. This was mainly due to an increase in SNR in the peripheral brain (an up to threefold SNR increase), whereas the SNR increase in the center of the brain was 4%. The incremental SNR gains became relatively small at large n, with a 9% gain observed when n was increased from 8 to 16. Compared to the (larger) product birdcage head coil, SNR increased by close to a factor of 2 in the center, and by up to a factor of 6 in the periphery of the brain. For low SENSE acceleration (rate-2), g-factors leveled off for n>4, and improved only slightly (1.4% averaged over brain) going from n=8 to n=16. Improvements in g for n>8 were larger for higher acceleration rates, with the improvement for rate-3 averaging 12.0%.


Subject(s)
Brain Mapping , Magnetic Resonance Imaging/instrumentation , Equipment Design , Humans , Radio Waves , Signal Processing, Computer-Assisted
5.
Magn Reson Med ; 51(1): 165-71, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14705057

ABSTRACT

A scalable multichannel digital MRI receiver system was designed to achieve high bandwidth echo-planar imaging (EPI) acquisitions for applications such as BOLD-fMRI. The modular system design allows for easy extension to an arbitrary number of channels. A 16-channel receiver was developed and integrated with a General Electric (GE) Signa 3T VH/3 clinical scanner. Receiver performance was evaluated on phantoms and human volunteers using a custom-built 16-element receive-only brain surface coil array. At an output bandwidth of 1 MHz, a 100% acquisition duty cycle was achieved. Overall system noise figure and dynamic range were better than 0.85 dB and 84 dB, respectively. During repetitive EPI scanning on phantoms, the relative temporal standard deviation of the image intensity time-course was below 0.2%. As compared to the product birdcage head coil, 16-channel reception with the custom array yielded a nearly 6-fold SNR gain in the cerebral cortex and a 1.8-fold SNR gain in the center of the brain. The excellent system stability combined with the increased sensitivity and SENSE capabilities of 16-channel coils are expected to significantly benefit and enhance fMRI applications.


Subject(s)
Brain/anatomy & histology , Magnetic Resonance Imaging/instrumentation , Electronics , Equipment Design , Humans , Phantoms, Imaging , Software
6.
J Neurophysiol ; 91(3): 1282-96, 2004 Mar.
Article in English | MEDLINE | ID: mdl-14614108

ABSTRACT

Functional neuroimaging experiments have revealed an organization of frequency-dependent responses in human auditory cortex suggestive of multiple tonotopically organized areas. Numerous studies have sampled cortical responses to isolated narrow-band stimuli, revealing multiple locations in auditory cortex at which the position of response varies systematically with frequency content. Because appropriate anatomical or functional grouping of these distinct frequency-dependent responses is uncertain, the number and location of tonotopic mappings within human auditory cortex remains unclear. Further, sampling does not address whether the observed mappings exhibit continuity as a function of position. This functional magnetic resonance imaging study used frequency-swept stimuli to identify progressions of frequency sensitivity across the cortical surface. The center-frequency of narrow-band, amplitude-modulated noise was slowly swept between 125 and 8,000 Hz. The latency of response relative to sweep onset was determined for each cortical surface location. Because frequency varied systematically with time, response latency indicated the frequency to which a location was maximally sensitive. Areas of cortex exhibiting a progressive change in response latency with position were considered tonotopically organized. There exist two main findings. First, six progressions of frequency sensitivity (i.e., tonotopic mappings) were repeatably observed in the superior temporal plane. Second, the locations of the higher- and lower-frequency endpoints of these progressions were approximately congruent with regions reported to be most responsive to discrete higher- and lower-frequency stimuli. Based on these findings and previous anatomical work, we propose a correspondence between these progressions and anatomically defined cortical areas, suggesting that five areas in human auditory cortex exhibit at least six tonotopic organizations.


Subject(s)
Auditory Cortex/physiology , Pitch Discrimination/physiology , Acoustic Stimulation , Adult , Auditory Cortex/anatomy & histology , Brain Mapping , Female , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Male
7.
Magn Reson Med ; 47(6): 1218-27, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12111969

ABSTRACT

An 8-channel receive-only detector array was developed for SENSE MRI of human brain. The coil geometry was based on a gapped element design and used ultra-high impedance preamplifiers for mutual decoupling of the elements. Computer simulations of the electric and magnetic fields showed that excellent signal-to-noise ratio (SNR) and SENSE performance could be achieved by placing the coil elements close to the head and maintaining a substantial gap between the elements. Measurements with a 1.5 T prototype coil showed a 2.7-fold improvement of the SNR averaged over the brain compared to a conventional quadrature birdcage receive coil and an average geometrical noise amplification factor (g-value) of 1.06 and 1.38 for rate-2 and rate-3 SENSE, respectively.


Subject(s)
Brain/anatomy & histology , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/instrumentation , Computer Simulation , Humans , Magnetic Resonance Imaging/methods