Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Type of study
Publication year range
1.
J Infect Dev Ctries ; 13(6): 487-495, 2019 06 30.
Article in English | MEDLINE | ID: mdl-32058983

ABSTRACT

INTRODUCTION: Antibiotic-loaded bone cements of poly(methyl methacrylate) are considered as very useful biomaterials for the management of corporal deep osseous infections. However, the high prevalence of resistant germs and polymicrobial infections makes it necessary to search for new formulations of bone cements containing antibiotics for local antibacterial therapy. In this work, bone cements loaded with drugs with different mechanism of action were evaluated to determine its antibacterial effectiveness on Pseudomonas aeruginosa. METHODOLOGY: Poly(methyl methacrylate) cements loaded with 10 wt.% of Oleozon®, mixtures of Ciprofloxacin/Meropenem and Ciprofloxacin/Meropenem/Oleozon® were prepared. The in vitro drugs release in water was followed by UV-Vis spectroscopy, and their antibacterial activity against Pseudomonas aeruginosa was evaluated for 11 days using the microdilution method. RESULTS: All the extracts demonstrated an inhibitory effect on the growth of the strain during the whole trial period. Extracts from cement with Oleozon® only presented a total antibacterial inhibitory effect during 20 hours for the extracts taken at day 1 while the extracts from the cements loaded with mixtures of Ciprofloxacin/Meropenem and Ciprofloxacin/Meropenem/Oleozon® showed complete inhibition of the growth of the microorganism, even at 11 days. At the end of the trial period, some of the drugs remained inside the matrices, indicating that they can be released for a longer time in treatments. CONCLUSIONS: The results indicated a positive antibacterial effect by the combined used of the two or the three drugs tested against the Gram-negative bacilli Pseudomonas aeruginosa, so these proposal may be a valid alternative to be considered by surgeons.


Subject(s)
Anti-Bacterial Agents/pharmacology , Bone Cements/pharmacology , Polymethyl Methacrylate/pharmacology , Pseudomonas aeruginosa/drug effects , Anti-Bacterial Agents/pharmacokinetics , Drug Combinations , Microbial Sensitivity Tests
3.
Rev. cuba. farm ; 49(2)abr.-jun. 2015. graf, tab
Article in Spanish | CUMED | ID: cum-63293

ABSTRACT

Introducción: la cafeína es una sustancia que se encuentra en algunas plantas como el café, el té, el cacao, además es un ingrediente de algunos medicamentos como los analgésicos, es estimulante metabólico y del sistema nervioso central. Su consumo agudo o crónico puede dar lugar a una variedad de efectos adversos. Debido a su uso en la industria farmacéutica su determinación adquiere gran importancia. La validación de un método analítico demuestra científicamente que es adecuado para una aplicación específica, como la determinación de ingredientes farmacéuticos activos en disoluciones acuosas. Objetivo: validar un método analítico para la cuantificación por Cromatografía Líquida de Alta Resolución de la cafeína presente en disoluciones acuosas y la determinación de su contenido en muestras residuales acuosas de un laboratorio farmacéutico productor de medicamentos. Métodos: la validación del método cromatográfico se llevó a cabo empleando una columna RP-18 de 250 × 4,6 mm, 5 µm; Fase móvil: agua—CH3OH (70/30); flujo: 1,0 mL/min y un detector ultravioleta visible a 254 nm. La determinación de la cafeína se efectuó por el método validado según las regulaciones internacionales vigentes. Resultados: el método resultó selectivo frente a los productos de ozonización, lineal (r= 0,999 y r2= 0,999), preciso, exacto, robusto y sensible, en el intervalo de 1 × 10-4 mol/L a 2 × 10-3 mol ̸ L. Se evaluó la estabilidad del analito en las condiciones de análisis. El contenido de cafeína en aguas residuales de la industria farmacéutica productora del medicamento fue determinado en concentraciones inferiores a 3 × 10-4 mol/L. Conclusiones: el método validado fue selectivo, lineal, preciso, exacto y robusto en el intervalo de concentraciones analizado y permite la determinación de cafeína y del analito en disolución acuosa en muestras residuales acuosas del laboratorio farmacéutico productor del medicamento en Cuba(AU)


Introduction: caffeine is a substance located in some plants like coffee, tea, cocoa; it is also an ingredient of some drugs such as analgesics, a metabolic and central nervous system stimulant. The consumption of caffeine either acute or chronic may give rise to a variety of adverse effects. Due to its use in the drug industry, it is vitally important to determine it. The validation of an analytical method scientifically proves that it is adequate for a particular application as in the case of determination of active ingredients in aqueous solutions. Objective: to validate an analytical method for the quantitation by means of high performance liquid chromatography of the caffeine content in aqueous solutions and in wastewater samples from a drug manufacturing laboratory. Methods: the validation of the chromatographic method was performed by using a RP—18 de 250 x 4,6 mm, 5 µm column, a mobile phase: water/ CH3OH (70/30); Flow: 1,0 mL/min and an ultraviolet detector at 254 nm. The caffeine content was estimated by the high performance liquid chromatograpy following the international regulations in force. Results: the method was selective against the ozonization products, linear r = 0.999 y r2 = 0.999), precise, accurate, robust and sensitive in the 1x10-4mol/L to 2x10-3mol/L interval. The analyte stability was also evaluated under the analysis conditions. The caffeine content in wastewaters of the drug manufacturing industry was determined at concentrations lower than 3x10-4 mol/L. Conclusions: the validated method was selective, linear, precise, accurate and robust in the analyzed interval of concentrations and allows estimating the caffeine content in aqueous solutions and of the analyte in wastewater samples from a pharmaceutical laboratory that produces the drug in Cuba(AU)


Subject(s)
Humans , Chromatography, High Pressure Liquid/methods , Caffeine/adverse effects , Cuba , Drug Industry , Validation Studies as Topic
4.
Rev. cuba. farm ; 49(2)abr.-jun. 2015. ilus, tab
Article in Spanish | LILACS, CUMED | ID: lil-776400

ABSTRACT

Introducción: la cafeína es una sustancia que se encuentra en algunas plantas como el café, el té, el cacao, además es un ingrediente de algunos medicamentos como los analgésicos, es estimulante metabólico y del sistema nervioso central. Su consumo agudo o crónico puede dar lugar a una variedad de efectos adversos. Debido a su uso en la industria farmacéutica su determinación adquiere gran importancia. La validación de un método analítico demuestra científicamente que es adecuado para una aplicación específica, como la determinación de ingredientes farmacéuticos activos en disoluciones acuosas. Objetivo: validar un método analítico para la cuantificación por Cromatografía Líquida de Alta Resolución de la cafeína presente en disoluciones acuosas y la determinación de su contenido en muestras residuales acuosas de un laboratorio farmacéutico productor de medicamentos. Métodos: la validación del método cromatográfico se llevó a cabo empleando una columna RP-18 de 250 × 4,6 mm, 5 µm; Fase móvil: agua­CH3OH (70/30); flujo: 1,0 mL/min y un detector ultravioleta visible a 254 nm. La determinación de la cafeína se efectuó por el método validado según las regulaciones internacionales vigentes. Resultados: el método resultó selectivo frente a los productos de ozonización, lineal (r= 0,999 y r2= 0,999), preciso, exacto, robusto y sensible, en el intervalo de 1 × 10-4 mol/L a 2 × 10-3 mol ̸ L. Se evaluó la estabilidad del analito en las condiciones de análisis. El contenido de cafeína en aguas residuales de la industria farmacéutica productora del medicamento fue determinado en concentraciones inferiores a 3 × 10-4 mol/L. Conclusiones: el método validado fue selectivo, lineal, preciso, exacto y robusto en el intervalo de concentraciones analizado y permite la determinación de cafeína y del analito en disolución acuosa en muestras residuales acuosas del laboratorio farmacéutico productor del medicamento en Cuba(AU)


Introduction: caffeine is a substance located in some plants like coffee, tea, cocoa; it is also an ingredient of some drugs such as analgesics, a metabolic and central nervous system stimulant. The consumption of caffeine either acute or chronic may give rise to a variety of adverse effects. Due to its use in the drug industry, it is vitally important to determine it. The validation of an analytical method scientifically proves that it is adequate for a particular application as in the case of determination of active ingredients in aqueous solutions. Objective: to validate an analytical method for the quantitation by means of high performance liquid chromatography of the caffeine content in aqueous solutions and in wastewater samples from a drug manufacturing laboratory. Methods: the validation of the chromatographic method was performed by using a RP­18 de 250 x 4,6 mm, 5 µm column, a mobile phase: water/ CH3OH (70/30); Flow: 1,0 mL/min and an ultraviolet detector at 254 nm. The caffeine content was estimated by the high performance liquid chromatograpy following the international regulations in force. Results: the method was selective against the ozonization products, linear r = 0.999 y r2 = 0.999), precise, accurate, robust and sensitive in the 1x10-4mol/L to 2x10-3mol/L interval. The analyte stability was also evaluated under the analysis conditions. The caffeine content in wastewaters of the drug manufacturing industry was determined at concentrations lower than 3x10-4 mol/L. Conclusions: the validated method was selective, linear, precise, accurate and robust in the analyzed interval of concentrations and allows estimating the caffeine content in aqueous solutions and of the analyte in wastewater samples from a pharmaceutical laboratory that produces the drug in Cuba(AU)


Subject(s)
Humans , Caffeine/adverse effects , Drug Industry , Chromatography, High Pressure Liquid/methods , Cuba , Validation Studies as Topic
5.
Rev. cuba. farm ; 48(4)oct.-dic. 2014. ilus, tab
Article in Spanish | LILACS, CUMED | ID: lil-748771

ABSTRACT

INTRODUCCIÓN: la evaluación de hormonas en pacientes de endocrinología y bioquímica clínica, entre otros, se realiza actualmente por métodos de inmunoensayo con las desventajas inherentes a este tipo de análisis (ejemplo: reacciones cruzadas). Con la aplicación de la espectrometría de masas acoplada a cromatografía de gases es posible aumentar la sensibilidad y especificidad de los análisis. OBJETIVO: validar un ensayo que permita la cuantificación de 21 hormonas mediante la técnica de cromatografía de gases-espectrometría de masas con propósitos de pesquizaje. MÉTODOS: el ensayo se basó en una extracción en fase sólida con columnas DetectabuseTM y posterior extracción líquido-líquido a pH básico. Los derivados trimetilsilil se analizaron con un cromatógrafo de gases Hewlett-Packard 6890 acoplado a un espectrómetro de masas cuadrupolar serie 5973. La columna capilar fue HP Ultra-1 (17 m x 0,20 mm x 0,11 µm). La adquisición fue realizada en modo SIM (monitoreo selectivo de iones). RESULTADOS: los resultados del proceso de validación cumplieron con los criterios de aceptación de una manera adecuada correspondiente a un método con propósitos de pesquizaje. El método resultó ser específico para los 21 compuestos estudiados, lineal (r2= 0,900-0,996) y preciso (CV entre 1,4-9,6 por ciento). El rendimiento de extracción se mantuvo entre 69-117 por ciento. La robustez con variación de disolvente mostró recobrados entre 69-139 por ciento. CONCLUSIONES: los resultados demuestran que la técnica analítica desarrollada para la cuantificación de los 21 compuestos esteroidales en orina, es exacta, específica, lineal, precisa y robusta para su aplicación con propósitos de pesquizaje en estudios endocrinológicos clínicos(AU)


INTRODUCTION: the evaluation of hormones on endocrinology and clinical biochemistry patients, among others, is presently performed, using inmunoassays with its intrinsic disadvantages such as cross reactions. The application of gas chromatography coupled to mass spectrometry allows increasing the sensitivity and specificity of this analysis. OBJECTIVE: to validate an assay for quantitation of 21 hormones by the analytical technique of gas chromatography - mass spectrometry for screening purposes. METHODS: the assay followed a solid-phase extraction using DetectabuseTM columns and subsequently liquid-liquid extraction at basic pH. Trimethylsilyl derivatives were evaluated on Hewlett-Packard 6890 gas chromatograph coupled to serial 5973 quadrupolar mass spectrometer. The capillary column was HP Ultra-1 (17 m x 0.20 mm x 0.11 µm). Data was gathered following SIM mode (selective ion monitoring). RESULTS: the results of the validation process adequately fulfilled the acceptance criteria for screening purposes. The assay proved to be specific for all studied compounds, linear (r2= 0.900-0.996) and precise (VC 1.4-9.6 percent). The extraction yield was kept at 69-117 percent. The robustness assay with varying dissolvent showed extraction yields ranging 69-139 percent. CONCLUSIONS: results of the validation process show that the developed assay to simultaneously quantify 21 steroidal compounds in urine is exact, linear, precise, robust and specific for its application in clinical endocrine studies for screening purposes(AU)


Subject(s)
Humans , Male , Female , Validation Studies as Topic , Hormone Antagonists , Gas Chromatography-Mass Spectrometry/methods
6.
Rev. cuba. farm ; 48(4): 550-561, oct.-dic. 2014. ilus
Article in Spanish | CUMED | ID: cum-61942

ABSTRACT

Introducción: la evaluación de hormonas en pacientes de endocrinología y bioquímica clínica, entre otros, se realiza actualmente por métodos de inmunoensayo con las desventajas inherentes a este tipo de análisis (ejemplo: reacciones cruzadas). Con la aplicación de la espectrometría de masas acoplada a cromatografía de gases es posible aumentar la sensibilidad y especificidad de los análisis. Objetivo: validar un ensayo que permita la cuantificación de 21 hormonas mediante la técnica de cromatografía de gases-espectrometría de masas con propósitos de pesquizaje. Métodos: el ensayo se basó en una extracción en fase sólida con columnas DetectabuseTM y posterior extracción líquido-líquido a pH básico. Los derivados trimetilsilil se analizaron con un cromatógrafo de gases Hewlett-Packard 6890 acoplado a un espectrómetro de masas cuadrupolar serie 5973. La columna capilar fue HP Ultra-1 (17 m x 0,20 mm x 0,11 µm). La adquisición fue realizada en modo SIM (monitoreo selectivo de iones). Resultados: los resultados del proceso de validación cumplieron con los criterios de aceptación de una manera adecuada correspondiente a un método con propósitos de pesquizaje. El método resultó ser específico para los 21 compuestos estudiados, lineal (r2= 0,900-0,996) y preciso (CV entre 1,4-9,6 por ciento). El rendimiento de extracción se mantuvo entre 69-117 por ciento. La robustez con variación de disolvente mostró recobrados entre 69-139 por ciento. Conclusiones: los resultados demuestran que la técnica analítica desarrollada para la cuantificación de los 21 compuestos esteroidales en orina, es exacta, específica, lineal, precisa y robusta para su aplicación con propósitos de pesquizaje en estudios endocrinológicos clínicos(AU)


Introduction: the evaluation of hormones on endocrinology and clinical biochemistry patients, among others, is presently performed, using inmunoassays with its intrinsic disadvantages such as cross reactions. The application of gas chromatography coupled to mass spectrometry allows increasing the sensitivity and specificity of this analysis. Objective: to validate an assay for quantitation of 21 hormones by the analytical technique of gas chromatography - mass spectrometry for screening purposes. Methods: the assay followed a solid-phase extraction using DetectabuseTM columns and subsequently liquid-liquid extraction at basic pH. Trimethylsilyl derivatives were evaluated on Hewlett-Packard 6890 gas chromatograph coupled to serial 5973 quadrupolar mass spectrometer. The capillary column was HP Ultra-1 (17 m x 0.20 mm x 0.11 µm). Data was gathered following SIM mode (selective ion monitoring). Results: the results of the validation process adequately fulfilled the acceptance criteria for screening purposes. The assay proved to be specific for all studied compounds, linear (r2= 0.900-0.996) and precise (VC 1.4-9.6 percent). The extraction yield was kept at 69-117 percent. The robustness assay with varying dissolvent showed extraction yields ranging 69-139 percent. Conclusions: results of the validation process show that the developed assay to simultaneously quantify 21 steroidal compounds in urine is exact, linear, precise, robust and specific for its application in clinical endocrine studies for screening purposes(AU)


Subject(s)
Validation Studies as Topic , Gas Chromatography-Mass Spectrometry/methods , Hormone Antagonists
SELECTION OF CITATIONS
SEARCH DETAIL
...