Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(19)2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37836978

ABSTRACT

Photoacoustic (PA) imaging is a non-invasive biomedical imaging technique that combines the benefits of optics and acoustics to provide high-resolution structural and functional information. This review highlights the emergence of three-dimensional handheld PA imaging systems as a promising approach for various biomedical applications. These systems are classified into four techniques: direct imaging with 2D ultrasound (US) arrays, mechanical-scanning-based imaging with 1D US arrays, mirror-scanning-based imaging, and freehand-scanning-based imaging. A comprehensive overview of recent research in each imaging technique is provided, and potential solutions for system limitations are discussed. This review will serve as a valuable resource for researchers and practitioners interested in advancements and opportunities in three-dimensional handheld PA imaging technology.


Subject(s)
Imaging, Three-Dimensional , Photoacoustic Techniques , Ultrasonography , Spectrum Analysis , Photoacoustic Techniques/methods
2.
Photoacoustics ; 31: 100512, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37252650

ABSTRACT

Photoacoustic (PA) imaging has gained much attention, providing structural and functional information in combination with clinical ultrasound (US) imaging systems. 2D PA and US imaging is easily implemented, but its heavy dependence on operator skills makes 3D imaging preferable. In this study, we propose a panoramic volumetric clinical PA and US imaging system equipping a handheld imaging scanner weighing 600 g and measuring 70 × 62 × 110 mm3. Multiple PA/US scans were performed to cover a large field-of-view (FOV), and the acquired PA/US volumes were mosaic-stitched after manually correcting the positions and rotations in a total of 6 degrees of freedom. PA and US maximum amplitude projection images were visualized online, while spectral unmixed data was quantified offline. The performance of the system was tested via tissue-mimicking phantom experiments. The system's potential was confirmed in vivo by panoramically imaging vascular networks in human arms and necks, with FOVs of 331 × 38 and 129 × 120 mm2, respectively. Further, we quantified hemoglobin oxygen saturation levels in the radial artery, brachial artery, carotid artery, and jugular vein. We hope that this system can be applied for various clinical fields such as cardiovascular imaging, dermatology, vascular surgery, internal medicine, and oncology.

3.
Opt Lett ; 48(2): 343-346, 2023 Jan 15.
Article in English | MEDLINE | ID: mdl-36638453

ABSTRACT

Two-dimensional matrix transducer arrays are the most appropriate imaging probes for acquiring dual-modal 3D photoacoustic (PA)/ultrasound (US) images. However, they have small footprints which limit the field-of-view (FOV) to less than 10 mm × 10 mm and degrade the spatial resolution. In this study, we demonstrate a dual-modal PA and US imaging system (using a 2D matrix transducer array and a motorized 2D scanning system) to enlarge the FOV of volumetric images. Multiple PA volumes were merged to form a wide-field image of approximately 45 mm × 45 mm. In vivo imaging was demonstrated using rat sentinel lymph nodes (SLNs) and bladders stained with methylene blue. We believe that this volumetric PA/US imaging technique with a 2D matrix transducer array can be a useful tool for narrow-field real-time monitoring and wide-field imaging of various preclinical and clinical studies.


Subject(s)
Imaging, Three-Dimensional , Photoacoustic Techniques , Rats , Animals , Ultrasonography/methods , Imaging, Three-Dimensional/methods , Phantoms, Imaging , Methylene Blue , Transducers , Photoacoustic Techniques/methods
4.
Biosensors (Basel) ; 12(12)2022 Nov 29.
Article in English | MEDLINE | ID: mdl-36551059

ABSTRACT

Three-dimensional (3D) handheld photoacoustic (PA) and ultrasound (US) imaging performed using mechanical scanning are more useful than conventional 2D PA/US imaging for obtaining local volumetric information and reducing operator dependence. In particular, 3D multispectral PA imaging can capture vital functional information, such as hemoglobin concentrations and hemoglobin oxygen saturation (sO2), of epidermal, hemorrhagic, ischemic, and cancerous diseases. However, the accuracy of PA morphology and physiological parameters is hampered by motion artifacts during image acquisition. The aim of this paper is to apply appropriate correction to remove the effect of such motion artifacts. We propose a new motion compensation method that corrects PA images in both axial and lateral directions based on structural US information. 3D PA/US imaging experiments are performed on a tissue-mimicking phantom and a human wrist to verify the effects of the proposed motion compensation mechanism and the consequent spectral unmixing results. The structural motions and sO2 values are confirmed to be successfully corrected by comparing the motion-compensated images with the original images. The proposed method is expected to be useful in various clinical PA imaging applications (e.g., breast cancer, thyroid cancer, and carotid artery disease) that are susceptible to motion contamination during multispectral PA image analysis.


Subject(s)
Photoacoustic Techniques , Humans , Photoacoustic Techniques/methods , Imaging, Three-Dimensional/methods , Motion , Image Processing, Computer-Assisted/methods , Hemoglobins , Artifacts
5.
Opt Express ; 30(18): 32031-32050, 2022 Aug 29.
Article in English | MEDLINE | ID: mdl-36242273

ABSTRACT

The OH radical concentration was measured by applying tunable diode laser absorption spectroscopy, which is an in situ optical method. An optical absorption region (P7.5ff transition at 1502.7 nm) of the OH radical was selected in the near-infrared range to measure the OH radicals quantitatively in premixed CH4/air flames. An improved direct absorption spectroscopy (DAS) method based on wavelength division multiplexing was proposed to extract the H2O absorption signal that interfered with the OH light absorption signal, and the integral intensity of OH* chemiluminescence was compared to the measured OH radical concentration based on the improved DAS method.

6.
Radiology ; 303(2): 467-473, 2022 05.
Article in English | MEDLINE | ID: mdl-35191741

ABSTRACT

Background Monitoring the microcirculation in human feet is crucial in assessing peripheral vascular diseases, such as diabetic foot. However, conventional imaging modalities are more focused on diagnosis in major arteries, and there are limited methods to provide microvascular information in early stages of the disease. Purpose To investigate a three-dimensional (3D) noncontrast bimodal photoacoustic (PA)/US imaging system that visualizes the human foot morphologically and also reliably quantifies podiatric vascular parameters noninvasively. Materials and Methods A clinically relevant PA/US imaging system was combined with a foot scanner to obtain 3D PA and US images of the human foot in vivo. Healthy participants were recruited from September 2020 to June 2021. The collected 3D PA and US images were postprocessed to present structural information about the foot. The quantitative reliability was evaluated in five repeated scans of 10 healthy feet by calculating the intraclass correlation coefficient and minimal detectable change, and the detectability of microvascular changes was tested by imaging 10 healthy feet intentionally occluded with use of a pressure cuff (160 mm Hg). Statistically significant difference is indicated with P values. Results Ten feet from six healthy male volunteers (mean age ± standard deviation, 27 years ± 3) were included. The foot images clearly visualized the structure of the vasculature, bones, and skin and provided such functional information as the total hemoglobin concentration (HbT), hemoglobin oxygen saturation (SO2), vessel density, and vessel depth. Functional information from five independent measurements of 10 healthy feet was moderately reliable (intraclass correlation coefficient, 0.51-0.74). Significant improvements in HbT (P = .006) and vessel density (P = .046) as well as the retention of SO2 were observed, which accurately described the microvascular change due to venous occlusion. Conclusion Three-dimensional photoacoustic and US imaging was able to visualize morphologic and physiologic features of the human foot, including the peripheral microvasculature, in healthy volunteers. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Mezrich in this issue.


Subject(s)
Imaging, Three-Dimensional , Lower Extremity , Adult , Hemoglobins , Humans , Imaging, Three-Dimensional/methods , Male , Microvessels , Reproducibility of Results , Young Adult
7.
Sensors (Basel) ; 20(10)2020 May 12.
Article in English | MEDLINE | ID: mdl-32408675

ABSTRACT

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ-ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%-34.3%, fall time increase of 201-1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07-11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

8.
Photoacoustics ; 18: 100173, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32215250

ABSTRACT

Clinical 2D photoacoustic (PA) imaging can be easily implemented in a traditional ultrasound (US) system. However, 3D PA imaging is still preferable because 2D B-mode PA/US imaging suffers from low reproducibility and high-operator dependency. Here, we demonstrate a compact clinical handheld 3D PA/US scanner using an 1D linear array US transducer combined with a mechanical scanning stage working via a Scotch yoke mechanism. The entire scanner measures just 100 × 80 × 100 mm3 and weighs only 950 g, so it can easily be operated by hand. Blood vessels and hemoglobin oxygen saturation images of different parts of the human body (e.g., neck, wrist, thigh, and instep) have been successfully acquired. The system can potentially be used for clinical applications in fields such as oncology, dermatology, nephrology, and internal medicine.

SELECTION OF CITATIONS
SEARCH DETAIL
...