Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
J Med Internet Res ; 22(5): e19540, 2020 05 05.
Article in English | MEDLINE | ID: mdl-32353827

ABSTRACT

BACKGROUND: Low infection and case-fatality rates have been thus far observed in Taiwan. One of the reasons for this major success is better use of big data analytics in efficient contact tracing and management and surveillance of those who require quarantine and isolation. OBJECTIVE: We present here a unique application of big data analytics among Taiwanese people who had contact with more than 3000 passengers that disembarked at Keelung harbor in Taiwan for a 1-day tour on January 31, 2020, 5 days before the outbreak of coronavirus disease (COVID-19) on the Diamond Princess cruise ship on February 5, 2020, after an index case was identified on January 20, 2020. METHODS: The smart contact tracing-based mobile sensor data, cross-validated by other big sensor surveillance data, were analyzed by the mobile geopositioning method and rapid analysis to identify 627,386 potential contact-persons. Information on self-monitoring and self-quarantine was provided via SMS, and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) tests were offered for symptomatic contacts. National Health Insurance claims big data were linked, to follow-up on the outcome related to COVID-19 among those who were hospitalized due to pneumonia and advised to undergo screening for SARS-CoV-2. RESULTS: As of February 29, a total of 67 contacts who were tested by reverse transcription-polymerase chain reaction were all negative and no confirmed COVID-19 cases were found. Less cases of respiratory syndrome and pneumonia were found after the follow-up of the contact population compared with the general population until March 10, 2020. CONCLUSIONS: Big data analytics with smart contact tracing, automated alert messaging for self-restriction, and follow-up of the outcome related to COVID-19 using health insurance data could curtail the resources required for conventional epidemiological contact tracing.


Subject(s)
Big Data , Contact Tracing/methods , Coronavirus Infections/diagnosis , Coronavirus Infections/prevention & control , Disease Outbreaks/prevention & control , Pandemics/prevention & control , Pneumonia, Viral/diagnosis , Pneumonia, Viral/prevention & control , Public Health Surveillance/methods , Quarantine/methods , Ships , Betacoronavirus/isolation & purification , COVID-19 , Communicable Disease Control , Coronavirus Infections/epidemiology , Coronavirus Infections/transmission , Disease Outbreaks/statistics & numerical data , Geographic Information Systems , Humans , Pandemics/statistics & numerical data , Pneumonia, Viral/epidemiology , Pneumonia, Viral/transmission , Retrospective Studies , SARS-CoV-2 , Taiwan/epidemiology
2.
Nanoscale Res Lett ; 13(1): 411, 2018 Dec 22.
Article in English | MEDLINE | ID: mdl-30578467

ABSTRACT

High-brightness white-light-emitting diodes (w-LEDs) with excellent color quality is demonstrated by using nontoxic nanomaterials. Previously, we have reported the high color quality w-LEDs with heavy-metal phosphor and quantum dots (QDs), which may cause environmental hazards. In the present work, liquid-type white LEDs composed of nontoxic materials, named as graphene and porous silicon quantum dots are fabricated with a high color rendering index (CRI) value gain up to 95. The liquid-typed device structure possesses minimized surface temperature and 25% higher value of luminous efficiency as compare to dispensing-typed structure. Further, the as-prepared device is environment friendly and attributed to low toxicity. The low toxicity and high R9 (87) component values were conjectured to produce new or improve current methods toward bioimaging application.

3.
Appl Opt ; 51(16): 3558-63, 2012 Jun 01.
Article in English | MEDLINE | ID: mdl-22695595

ABSTRACT

This study presents a special k-type (45°, 135°) microprism structure design for the lateral-type semiconductor laser of optical systems. This study combines front- and back-side inclined exposure technology to develop a k-type microprism structure and replaces the optical prism manufactured through traditional machine processing or injection molding with a new polymer (thick-film negative photoresists) micro-optical prism structure. To obtain the optimal structural surface roughness (12-15 nm at 400 µm×400 µm area), the percentage of polymer material loss caused by the solvent was controlled. This roughness level meets Blu-ray specifications (λ/10, λ=405 nm).

SELECTION OF CITATIONS
SEARCH DETAIL