Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Peripher Nerv Syst ; 16(2): 143-6, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21692914

ABSTRACT

Various phenotypes have been reported in Charcot-Marie-Tooth (CMT) disease carrying mutations in the ganglioside-induced differentiation-associated protein 1 (GDAP1) gene. Here, we report two recessive intermediate Charcot-Marie-Tooth (RI-CMT) patients with GDAP1 missense mutations: a His256Arg homozygous mutation (c.767A>G + c.767A>G) and compound mutations of heterozygous Pro111His (c.332C>A) and Val219Gly (c.656T>G). The Pro111His and Val219Gly are unreported mutations, but the His256Arg was previously reported. In both patients, histopathological findings showed well-documented features of mixed demyelinating and axonal neuropathies, and nerve conduction velocities fall in the intermediate range. In addition, the patterns of fatty substitutions in leg magnetic resonance imaging (MRI) were different by the mutation sites within the same GDAP1 gene.


Subject(s)
Charcot-Marie-Tooth Disease/genetics , Charcot-Marie-Tooth Disease/pathology , Mutation, Missense , Nerve Tissue Proteins/genetics , Charcot-Marie-Tooth Disease/physiopathology , Child , Child, Preschool , DNA Mutational Analysis , Female , Genes, Recessive , Humans , Male , Point Mutation
2.
Article in English | MEDLINE | ID: mdl-19789213

ABSTRACT

In this work, we analyze the baseline, signal strength, aortic augmentation index (AIx), radial AIx, time to reflection and P_T2 at Chon, Gwan, and Cheok, which are the three pulse diagnosis positions in Oriental medicine. For the pulse measurement, we used the SphygmoCor apparatus, which has been widely used for the evaluation of the arterial stiffness at the aorta. By two-way repeated measures analysis of variance, we tested two independent measurements for repeatability and investigated their mean differences among Chon, Gwan and Cheok. To characterize further the parameters that were shown to be different between each palpation position, we carried out Duncan's test for the multiple comparisons. The baseline and signal strength were statistically different (P < .05) among Chon, Gwan and Cheok, respectively, which supports the major hypothesis of Oriental medicine that all of the three palpation positions contain different clinical information. On the other hand, aortic AIx and time to reflection were found to be statistically different between Chon and the others, and radial AIx and P_T2 did not show any difference between pulse positions. In the clinical sense, however, the aortic AIx at each palpation position was found to fall within the 90% confidence interval of normal arterial compliance. The results of the multiple comparisons indicate that the parameters of arterial stiffness were independent of the palpation positions. This work is the first attempt to characterize quantitatively the pulse signals at Chon, Gwan and Cheok with some relevant parameters extracted from the SphygmoCor apparatus.

SELECTION OF CITATIONS
SEARCH DETAIL
...