Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
Add more filters










Publication year range
1.
J Korean Assoc Oral Maxillofac Surg ; 49(6): 354-359, 2023 Dec 31.
Article in English | MEDLINE | ID: mdl-38155089

ABSTRACT

The temporomandibular joint is a unique structure composed of the joint capsule, articular disc, mandibular condyles, glenoid fossa of the temporal bone, surrounding ligaments, and associated muscles. The condyle is one of the major components of a functional temporomandibular joint. Reconstruction of large mandibular defects involving the condyle is a surgical challenge for oral and maxillofacial surgeons. To restore large mandibular defects, there are different options for free flap method such as fibula, scapula, and iliac crest. Currently, the vascularized fibula free flap is the gold standard for reconstruction of complex mandibular defects involving the condyle. In the present report, neocondyle regeneration after mandible reconstruction including the condyle head with fibula free flap was evaluated. In this report, two patients were evaluated periodically, and remodeling of the distal end of the free fibula was observed in both cases after condylectomy or mandibulectomy. With preservation of the articular disc, trapezoidal shaping of the neocondyle, and elastic guidance of occlusion, neocondyle bone regeneration occured without ankylosis. Preservation of the articular disc and maintenance of proper occlusion are critical factors in regeneration of the neocondyle after mandible reconstruction.

2.
J Craniomaxillofac Surg ; 51(9): 543-550, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37574384

ABSTRACT

The aim of this study was to convert medical images stored in 3 mm slices in the picture archiving and communication system (PACS) to 1 mm slices, using artificial intelligence (AI), and to analyze the accuracy of the AI. The original 1.0 mm CT slices of the facial bone were obtained from 30 patients and reformatted to a rough CT slice of 3.0 mm. CT slices of 1.0 mm were subsequently reconstructed from those of 3.0 mm using AI. The AI and rough CT images were superimposed on the original CT images. Fourteen hard-tissue and five soft-tissue landmarks were selected for measuring the discrepancy. The overall average differences in values for the hard-tissue landmarks were 1.31 ± 0.38 mm and 0.81 ± 0.17 mm for the rough and AI CT images, respectively. The values for the soft-tissue landmarks were 1.18 ± 0.35 mm and 0.54 ± 0.17 mm for the rough and AI CT images, respectively. The differences for all the landmarks, excluding point A and pogonion, were statistically significant. Within the limitations of the study it seems that CT images reconstructed using AI might provide more accurate clinical information with a discrepancy of less than 1.0 mm.

3.
Maxillofac Plast Reconstr Surg ; 45(1): 25, 2023 Jul 27.
Article in English | MEDLINE | ID: mdl-37495896

ABSTRACT

BACKGROUND: The use of beta-tricalcium phosphate (beta-TCP) in dental surgery is limited owing to its rapid absorption compared to mixed formulations of hydroxyapatite. However, newly developed pure beta-TCP crystals have demonstrated slow absorption; hence, they last longer within the defect and act as a scaffold until new bone formation. The oral environment is unique and can prove unfavorable for bone grafts due to the high infection rate in the oral cavity and the fragile condition of the oral mucosa. The aim of this study was to evaluate the feasibility of using pure beta-TCP bone grafts in various dental treatments. METHODS: Panoramic X-ray images of 25 patients who underwent bone grafting during dental surgery were analyzed. A specially treated pure beta-TCP crystal, Neo Bone® (Neo Bone®, SN Biologics Co., Ltd, Seoul, Korea), was used in this study. The bone density at the graft site was compared with that of the surrounding bone using the ImageJ software (Wayne Rasband, NIH USA). RESULTS: Six months after surgery, the bone graft density was similar to that of the surrounding bone in 20 patients and increased in 5 patients. No adverse effects, such as infection, dehiscence, or graft failure, were observed. CONCLUSION: The newly developed pure beta-TCP crystal was slowly absorbed and served as support until new bone formation at the defect site, thus demonstrating its potential for use in various oral conditions requiring bone grafting.

4.
J Craniofac Surg ; 34(5): 1493-1495, 2023.
Article in English | MEDLINE | ID: mdl-36935402

ABSTRACT

BACKGROUND: There are many different techniques to achieve intermaxillary fixation (IMF) for open reduction of mandible fractures. The arch bar has long been used as the gold standard of IMF to assist open reduction. However, owing to its long operating time, risk of needle stick injury, and gingival trauma, surgeons looked into different treatment options for IMF, such as the skeletal anchorage system (SAS). Therefore, this study aimed to compare the stability between IMF with arch bar and IMF with SAS based on computed tomography image. MATERIALS AND METHODS: In this retrospective study, postoperative computed tomography and panoramic radiographs were taken 1 week and 6 months after surgery, respectively. The treatment of mandibular fractures using IMF with arch bar and SAS were compared by evaluating changes in the dental midlines and condyle positions. Thirty patients with mandibular fractures were enrolled into 2 groups-IMF with arch bar and IMF with SAS. RESULTS: The arch bar showed slightly more deviation in dental midline. In SAS, the condyle moved more medially compared with the arch bar. CONCLUSIONS: Skeletal anchorage system could be used for IMF with reliable stability in mandible fracture. There were no significant differences in the treatment outcome between the 2 groups.


Subject(s)
Mandibular Fractures , Humans , Mandibular Fractures/diagnostic imaging , Mandibular Fractures/surgery , Retrospective Studies , Fracture Fixation, Internal/methods , Treatment Outcome , Jaw Fixation Techniques , Mandible
5.
Anal Chem ; 95(5): 2832-2837, 2023 Feb 07.
Article in English | MEDLINE | ID: mdl-36625765

ABSTRACT

Cloud point temperature (Tcp) is a thermal index used to define the phase transition of thermoresponsive polymers. In this study, we used electrochemical techniques to obtain an electrochemical cloud point temperature (Tecp) that exhibits the more accurate phase transition temperature and can replace Tcp. Thermoamperometry on an ultramicroelectrode was conducted with a poly(arylene ether sulfone) (PES10) as a model system to obtain a current-temperature (i-T) curve in real time; the Tecp of the PES10 was determined from the i-T curve. The i-T curve shows an unprecedented current decrease in the PES10 solution despite increasing temperature; on the other hand, the current increased linearly with increasing temperature in the solution without PES10. This phenomenon was analyzed by considering the characteristics of PES10 during phase transition, such as dynamic viscosity, temperature of the solution, and electrode impedance. It was confirmed that the current drops shown in the i-T curves were mainly due to the decrease of real electrode area. The comparison of Tecp and Tcp showed that both depended similarly on the concentrations of the thermoresponsive polymer and the supporting electrolyte. The results reveal that by adjusting the concentration of polymer and electrolyte in an organic solution, Tecp, as a new analytical method, can be used in electric circuit-based energy storage appliances such as Li-ion batteries and supercapacitors.

6.
Maxillofac Plast Reconstr Surg ; 44(1): 31, 2022 Oct 04.
Article in English | MEDLINE | ID: mdl-36195777

ABSTRACT

BACKGROUND: The mandible is a functional bio-organ that supports facial structures and helps mastication and speaking. Large mandible defects, generally greater than 6-cm segment loss, may require composite tissue reconstruction such as osteocutaneous-vascularized free flap which has a limitation of additional surgery and a functional morbidity at the donor site. A 3D bio-printing technology is recently developed to overcome the limitation in the composite reconstruction of the mandible using osteocutaneous-vascularized free flap. REVIEW: Scaffold, cells, and bioactive molecules are essential for a 3D bio-printing. For mandibular reconstruction, materials in a 3D bio-printing require mechanical strength, resilience, and biocompatibility. Recently, an integrated tissue and organ printing system with multiple cartridges are designed and it is capable of printing polymers to reinforce the printed structure, such as hydrogel. CONCLUSION: For successful composite tissue reconstruction of the mandible, biologic considerations and components should be presented with a comprehensive on-demand online platform model of customized approaches.

7.
Nanoscale ; 14(18): 6981-6989, 2022 May 16.
Article in English | MEDLINE | ID: mdl-35470845

ABSTRACT

Single-entity analysis is an important research topic in electrochemistry. To date, electrode collisions and subsequent electrode-particle interactions have been studied for many types of nano-objects, including metals, polymers, and micelles. Here we extend this nano-object electrochemistry analysis to Pickering emulsions for the first time. The electrochemistry of Pickering emulsions is important because the internal space of a Pickering emulsion can serve as a reactor or template; this leads to myriad possible applications, all the while maintaining mechanical stability far superior to what is exhibited by conventional emulsions. This work showed that Pickering emulsions exhibit similar hydrodynamic behavior to other nano-objects, despite the complex structure involving hard nanoparticle surfactants, and the electron-transport mechanism into the internal volume of Pickering emulsions was elucidated. The Pickering emulsion electrochemistry platform developed here can be applied to electrochemical nanomaterial synthesis, surmounting the challenges faced by conventional synthetic strategies involving normal emulsions.

8.
Materials (Basel) ; 14(22)2021 11 22.
Article in English | MEDLINE | ID: mdl-34832480

ABSTRACT

Understanding the bond behavior of steel rebar in concrete is important in order to determine the performance of a reinforced concrete structure. Although numerous studies have been carried out by many researchers to develop a robust model for numerical analysis, no consensus has been reached as the bond behavior depends on hysteresis. In this study, the bond behavior of a steel bar in concrete with pre-existing damage is investigated under low-level cyclic loading. Based on the experimental bond stress and slip curve, a numerical model for finite element analysis to simulate the effect of low-level cyclic loading is proposed. The results from the numerical analysis show good agreement with the experimental data, including accumulated damage on stiffness and strength throughout entire load cycles.

9.
Article in English | MEDLINE | ID: mdl-33807042

ABSTRACT

The recent COVID-19 pandemic has been disrupting the daily lives of people across the world, causing a major concern for psychological well-being in children. This study aimed to examine (1) how life satisfaction and its potential predictors have been affected by the pandemic among school-aged children in Korea, and (2) which factors would predict their life satisfaction during the pandemic. We surveyed 166 fourth-graders in the Seoul metropolitan area to assess their psychological well-being and potentially related variables during the pandemic. The data were compared with those available from two pre-COVID-19 surveys, the 2018 Korean Children and Youth Panel Survey (n = 1236) and the 2019 Korean Children and Youth Well-being Index Survey (n = 334). Higher levels of stress were observed in children during the COVID-19 pandemic; however, the level of their life satisfaction remained unchanged when compared with data from the pre-COVID-19 surveys. The pandemic also affected peer relationship quality and susceptibility to smartphone addiction, but not perceived parenting style nor academic engagement. Interestingly, peer relationship quality no longer predicted life satisfaction during the pandemic; perceived parenting styles and parent-child conversation time predicted life satisfaction. The results suggest a central role of parent-child relationship in supporting the psychological well-being of school-aged children during the pandemic.


Subject(s)
COVID-19 , Pandemics , Adolescent , Child , Humans , Personal Satisfaction , Quality of Life , Republic of Korea/epidemiology , SARS-CoV-2 , Schools , Seoul
10.
J Craniomaxillofac Surg ; 49(8): 732-737, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33676816

ABSTRACT

This study aimed to elucidate whether the stability of an unsintered hydroxyapatite particles/poly-l-lactide (uHA/PLLA) system is comparable with that of titanium, according to different load-bearing areas of the mandible. The study included patients who underwent open reduction and internal fixation of the mandibular body, angle, or subcondylar fracture. The stability of uHA/PLLA systems was compared between the immediate and 6-month postoperative time points using three-dimensional cone-beam CT image analysis. The positional changes of each landmark were measured in three-dimensional (3D) coordinate systems using simulation software. Among 36 patients, there were more displacements of the landmarks between the immediate and 6-month postoperative time points after subcondylar fracture reduction than after body or angle fracture reductions. Strong upward displacements of the landmarks after subcondylar fracture reduction were found in the lateral pole [mean (SD) = 1.75 (3.16), p-value = 0.003] and medial pole [mean (SD) = 1.64 (2.50), p-value = 0.024], but not in the center. Subgroup analyses revealed similar unstable results in males on the condylar landmarks after subcondylar fracture reduction. There were tendencies for lateral displacement of the coronoid process in the body fracture group [mean (SD) = 0.8 (0.83)] and angle fracture group [mean (SD) = 0.75 (0.58)] postoperatively (p-value = 0.01). This study concluded that bioresorbable osteosynthesis can be recommended for body or angle fractures, while the indication for subcondylar fractures is less clear.


Subject(s)
Mandibular Fractures , Absorbable Implants , Bone Plates , Fracture Fixation, Internal , Humans , Male , Mandibular Condyle/diagnostic imaging , Mandibular Condyle/surgery , Mandibular Fractures/diagnostic imaging , Mandibular Fractures/surgery , Open Fracture Reduction
11.
Nucl Med Mol Imaging ; 54(6): 292-298, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33282000

ABSTRACT

PURPOSE: We aimed to evaluate the performance of hybrid bone single-photon emission computed tomography (SPECT)/computed tomography (CT) in predicting bone graft viability after maxillary or mandibular reconstructive surgery with vascularized bone grafts. METHODS: We retrospectively reviewed 46 bone planar scintigraphy and SPECT/CT images of 45 adult patients taken at 1 week (5-8 days) after maxillary or mandibular reconstructive surgery with vascularized bone grafts. By visual analysis, two nuclear medicine physicians scored the uptake degrees of each bone graft segment compared with the calvarium uptake on planar bone scintigraphy and SPECT/CT, respectively (0 = absence of uptake, 1 = less uptake, 2 = similar uptake, and 3 = more uptake). The imaging results were compared with clinical follow-up for assessing bone graft viability. RESULTS: During follow-up, five bone graft segments were surgically removed and confirmed as nonviable-one had a score of 0, although the other four had a score of 1-3 on planar bone scintigraphy. All five bone graft segments were scored 0 on SPECT/CT and eventually confirmed as nonviable. All other graft segments with a score of > 1 on SPECT/CT were viable and uneventful. The anatomical CT information on SPECT/CT images was helpful in discriminating bone graft uptake from adjacent bone or soft tissue uptake. CONCLUSIONS: The absence of tracer uptake by the vascularized bone graft on bone SPECT/CT at 1 week after maxillary or mandibular reconstructive surgery can predict graft failure. Bone SPECT/CT can be used to predict vascularized bone graft viability postoperatively.

12.
PLoS One ; 15(10): e0240352, 2020.
Article in English | MEDLINE | ID: mdl-33031474

ABSTRACT

Fixation materials used in the surgical treatment of subcondylar fractures contribute to successful clinical outcomes. In this study, we simulated the mechanical properties of four fixation materials [titanium (Ti), magnesium alloy (Mg alloy), poly-L-lactic acid (PLLA), and hydroxyapatite/poly-L-lactide (HA-PLLA)] in a finite-element analysis model of subcondylar fracture. Two four-hole plates were fixed on the anterior and posterior surfaces of the subcondyle of the mandible. In the simulation model of a subcondylar fracture, we evaluated the stress distribution and mechanical deformation of fixation materials. The stress distribution conspicuously appeared on the condylar neck of the non-fractured side and the center of the anterior plate for all materials. More stress distribution to the biologic component appeared with HA-PLLA than with Ti or Mg alloy, but its effects were less prominent than that of PLLA. The largest deformation was observed with PLLA, followed by HA-PLLA, Mg alloy, and Ti. The results of the present study imply the clinical potential of the HA-PLLA fixation material for open reduction of subcondylar fractures.


Subject(s)
Bone Screws , Finite Element Analysis , Mandibular Fractures/surgery , Absorbable Implants , Alloys/chemistry , Durapatite/chemistry , Elastic Modulus , Fracture Fixation, Internal/methods , Humans , Polyesters/chemistry , Tensile Strength , Titanium/chemistry
13.
Maxillofac Plast Reconstr Surg ; 42(1): 21, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32607318

ABSTRACT

BACKGROUND: Fibula free flap mandible reconstruction is the standard procedure after wide resection of the mandible. Establishment and maintenance of normal occlusion are important in mandible reconstruction both intraoperatively and after surgery. However, scar formation on the surgical site can cause severe fibrosis and atrophy of soft tissue in the head and neck region. CASE PRESENTATION: Here, we report a case of severe soft tissue atrophy that appeared along with scar formation after mandibular reconstruction through the fibular free flap procedure. This led to normal occlusion collapse after it was established, and the midline of the mandible became severely deviated to the affected side that was replaced with the fibula free flap, leading to facial asymmetry. We corrected the malocclusion with a secondary operation: a sagittal split ramus osteotomy on the unaffected side and a sliding osteotomy on the previous fibula graft. After a healing time of 3 months, implants were placed on the fibula graft for additional occlusal stability. CONCLUSION: We report satisfactory results from the correction of malocclusion after fibula reconstruction using sliding fibula osteotomy and sagittal split ramus osteotomy. The midline of the mandible returned to its original position and the degree of facial asymmetry was reduced. The implants reduced difficulties that the patient experienced with masticatory function.

14.
Materials (Basel) ; 13(10)2020 May 19.
Article in English | MEDLINE | ID: mdl-32438671

ABSTRACT

In the present study, the reproducibility and postoperative stability of a 3D printed surgical guide were evaluated in mandibular reconstruction with an osteocutaneous free flap (OCFF), including a fibular free flap (FFF) and deep circumflex iliac artery free flap (DCIA). Fifteen patients were enrolled, and a 3D surgical guide was fabricated by simulation surgery using preoperative (T0) Computed tomography (CT) images. Mandibular reconstruction was performed with OCFF using the 3D surgical guide. Postoperative CTs were taken immediately, 1 week (T1), and 6 months (T2) after surgery, to evaluate the reproducibility of the 3D surgical guide and condyle stability. Error of the 3D surgical guide ranged from 0.85 to 2.56 mm. There were no differences in reproducibility according to flap type. Condylar error and error at mandible midpoint were significantly different in FFF. However, there was no difference in DCIA error between the condyle and mandible midpoint. Regarding condyle stability 6 months after surgery, condyles moved more than 2 mm (up to 2.85 mm) in FFF, whereas there were no significant movement in DCIA. Careful intraoperative flap fixation and closed postoperative observation should be considered for stable clinical outcome, especially in the case of FFF.

15.
Materials (Basel) ; 13(1)2020 Jan 04.
Article in English | MEDLINE | ID: mdl-31947998

ABSTRACT

Recently, a hydroxyapatite particle/poly-L-lactide (HA-PLLA) composite device was introduced as an alternative to previous fixation systems. In this study, we used finite element analysis to simulate peak von Mises stress (PVMS) and deformation of bone plates and screws with the following four materials-Ti, Mg alloy, PLLA, and HA-PLLA-at a unilateral mandibular fracture. A three-dimensional virtual mandibular model was constructed, and the fracture surface was designed to run from the left mandibular angle. Masticatory loading was applied on the right first molars. Stress was concentrated at the upper part and the neck of the screw. The largest PVMS was observed for Ti; that was followed by Mg alloy, HA-PLLA, and PLLA. The largest deformation was observed for PLLA; next was HA-PLLA, then Mg alloy, and finally Ti. We could rank relative superiority in terms of mechanical properties. The HA-PLLA screw and mini-plate deformed less than 0.15 mm until 300 N. Thus, we can expect good bone healing with usual masticatory loading six weeks postoperatively. HA-PLLA is more frequently indicated clinically than PLLA owing to less deformation. If the quality of HA-PLLA fixation is improved, it could be widely utilized in facial bone trauma or craniofacial surgery.

16.
J Craniomaxillofac Surg ; 47(11): 1752-1757, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31445877

ABSTRACT

PURPOSE: The recent development of bioresorbable bone plates and screws allows plates to be applied to the load-bearing regions of the mandible and to remain in place over time without the need for removal. We hypothesized that the stability of composite plates and screws forged from unsintered hydroxyapatite particles and poly-l-lactide (u-HA/PLLA) is comparable to that of standard titanium fixation systems for the reduction of fractures of load-bearing regions of the mandibular body. MATERIALS AND METHODS: 40 patients underwent open reduction and internal fixation of the fractured mandibular body with either a titanium or u-HA/PLLA bone plate. Cone-beam CT images were obtained immediately postoperatively and at 6-month follow-up, and were analyzed for positional changes of the affected mandible. RESULTS: There were no significant differences in the postoperative positional changes of reference points between the titanium and u-HA/PLLA miniplates, except for that for the coronoid process (p-value = 0.03). Multivariate regression analysis revealed no significant differences in spatial changes between the immediate postoperative and 6-month follow-up images, after adjusting for age and sex. CONCLUSION: The stability of bioresorbable u-HA/PLLA miniplates and screws was comparable to that of titanium miniplates and screws immediately postoperatively and at 6-month follow-up, following surgical reduction of fractures of load-bearing regions of the mandibular body. Bioresorbable osteosynthesis can be considered a viable alternative to titanium osteosynthesis.


Subject(s)
Absorbable Implants , Bone Plates , Mandibular Fractures/surgery , Orthognathic Surgical Procedures/instrumentation , Polyesters/chemistry , Titanium/chemistry , Cone-Beam Computed Tomography , Durapatite , Fracture Fixation, Internal , Humans , Mandible/diagnostic imaging , Treatment Outcome
17.
J Craniofac Surg ; 30(6): 1829-1832, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31058721

ABSTRACT

A patient was diagnosed with squamous cell carcinoma of the maxillary sinus and consequently underwent a unilateral total maxillectomy and reconstruction using an anterolateral thigh (ALT) free flap. Soft tissue transplantation without a bone graft at the large maxillary defect site caused a midfacial collapse, which worsened, especially after radiotherapy. The 3-dimensional positioning of the composite flap for wide maxillary reconstruction is aesthetically important. To achieve ideal symmetry and aesthetics, a mirror image was created using the normal contralateral side. Through computer simulation, the function and symmetry of the virtually reconstructed maxilla was evaluated, and the surgical guide was made using a 3D printing system. Based on the prepared surgical guide, a deep circumflex iliac artery (DCIA) free flap was harvested, and its implementation in the reconstruction ultimately led to satisfactory results. Utilization of mirror image based virtual surgical planning and a 3D printing guide is a significantly effective method for maxilla reconstruction with DCIA flaps.


Subject(s)
Iliac Artery/diagnostic imaging , Maxilla/diagnostic imaging , Printing, Three-Dimensional , Computer Simulation , Free Tissue Flaps/transplantation , Humans , Iliac Artery/surgery , Male , Maxilla/blood supply , Maxilla/surgery , Middle Aged , Plastic Surgery Procedures/methods
18.
J Craniofac Surg ; 29(4): e394-e396, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29498977

ABSTRACT

A 21-year-old female patient underwent wide excision of the buccal mucosa and tongue as well as selective neck dissection due to squamous cell carcinoma on the left side of the tongue. She had a severe limitation in opening her mouth, owing to fibrosis of the mucosa and scar contracture after adjuvant radiation therapy. Reconstruction of the oral mucosa and tongue defect was performed after removal of the scar to improve mouth opening. An anterolateral thigh (ALT) flap was used, trimmed to an adipofascial flap for the reconstruction of the thin and pliable oral mucosa and tongue. The maximum mouth opening improved to 40 mm intraoperatively and was 30 mm after surgery. The adipofascial ALT flap had excellent viability and presented neomucosa after secondary healing. An adipofascial flap obtained by trimming an ALT flap could be a reliable option for the reconstruction of thin and pliable oral mucosa after wide excision of oral cancer.


Subject(s)
Free Tissue Flaps/surgery , Mouth Mucosa/surgery , Plastic Surgery Procedures/methods , Thigh/surgery , Tongue Neoplasms/surgery , Tongue/surgery , Adult , Carcinoma, Squamous Cell/surgery , Face/surgery , Female , Humans , Young Adult
19.
J Craniomaxillofac Surg ; 45(10): 1639-1646, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28818322

ABSTRACT

Mg-Ca-Zn alloy has been suggested for the application of fixation materials during maxillofacial surgery. We investigated the stability of Mg-Ca-Zn alloy for clinical application during orthognathic surgery. The finite element model for the fixation of sagittal split ramus osteotomy was constructed. In the bicortical screw fixation of the mandible setback condition, the stress distributions of Mg-Ca-Za alloy, polylactic acid polymer, and titanium were evaluated using the virtual model with occlusal loading of 132 N. The deformations of the three different materials of fixation screw were observed according to masticatory force ranging from 132 to 1,000 N. When comparing the stress distribution placed on cortical bone between the polymer and magnesium alloy groups, the magnesium alloy screws could bear more stress, thereby decreasing the stress, which might be distributed to other biologic components, such as the condyle and cortical ramus of the mandible. Deformations of the screws according to functional load were minimal, and the deformation remained <0.21 mm at the initial functional load of the mandible after surgery, regardless of materials used. The biodegradable magnesium alloy screw can bear more stress and decrease the detrimental effect on the stability of sagittal split ramus osteotomy setback surgery.


Subject(s)
Absorbable Implants , Alloys , Bone Screws , Osteotomy, Sagittal Split Ramus/instrumentation , Polymers , Calcium , Equipment Design , Finite Element Analysis , Imaging, Three-Dimensional , Magnesium , Materials Testing , Models, Theoretical , Titanium , Zinc
20.
J Korean Assoc Oral Maxillofac Surg ; 42(5): 265-270, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27847734

ABSTRACT

OBJECTIVES: To gain information on anatomical variation in anterolateral thigh (ALT) flaps in a series of clinical cases, with special focus on perforators and pedicles, for potential use in reconstruction of oral and maxillofacial soft tissue defects. MATERIALS AND METHODS: Eight patients who underwent microvascular reconstructive surgery with ALT free flaps after ablative surgery for oral cancer were included. The number of perforators included in cutaneous flaps, location of perforators (septocutaneous or musculocutaneous), and the course of vascular pedicles were intraoperatively investigated. RESULTS: Four cases with a single perforator and four cases with multiple perforators were included in the ALT flap designed along the line from anterior superior iliac spine to patella. Three cases had perforators running the septum between the vastus lateralis and rectus femoris muscle (septocutaneous type), and five cases had perforators running in the vastus lateralis muscle (musculocutaneous type). Regarding the course of vascular pedicles, five cases were derived from the descending branch of the lateral circumflex femoral artery (type I), and three cases were from the transverse branch (type II). CONCLUSION: Anatomical variation affecting the distribution of perforators and the course of pedicles might prevent use of an ALT free flap in various reconstruction cases. However, these issues can be overcome with an understanding of anatomical variation and meticulous surgical dissection. ALT free flaps are considered reliable options for reconstruction of soft tissue defects of the oral and maxillofacial area.

SELECTION OF CITATIONS
SEARCH DETAIL
...