Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
JAMA Cardiol ; 7(10): 1000-1008, 2022 10 01.
Article in English | MEDLINE | ID: mdl-36001335

ABSTRACT

Importance: In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective: To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants: SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention: Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures: The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results: A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Female , Heart Valve Prosthesis/adverse effects , Humans , Male , Prospective Studies , Stroke/epidemiology , Stroke/etiology
2.
Circ Cardiovasc Qual Outcomes ; 12(6): e005024, 2019 06.
Article in English | MEDLINE | ID: mdl-31181957

ABSTRACT

Background Implantable cardioverter-defibrillators (ICDs) are indicated in patients with left ventricular ejection fraction ≤35%, but many eligible patients do not receive this therapy. In this cluster randomized trial, we investigated the impact of a best practice alert (BPA) through the electronic health records on the rates of electrophysiology referrals, ICD implantations, and all-cause mortality in severe cardiomyopathy patients. Methods and Results Providers in the Heart and Vascular Institute (n=106) and in General Internal Medicine (n=89) were randomized to receive or not receive a BPA recommending consideration for ICD implantation. Patients belonging to the BPA and no BPA groups of providers were followed to the end points of electrophysiology referrals, ICD implantations, and all-cause mortality. Between 2013 and 2015, patients with reduced left ventricular ejection fraction were managed by 93 providers in the BPA (n=997 patients) and 102 providers in the no BPA (n=909 patients) groups. Patients in the 2 groups had comparable baseline characteristics. After a median follow-up of 36 months, 638 (33%) patients were referred to electrophysiology, 536 (27%) received an ICD, and 445 (23%) died. Patients in the BPA group were more likely to be referred to electrophysiology (hazard ratio=1.23; P=0.026), to receive ICD therapy (hazard ratio=1.35; P=0.006), and exhibited a trend towards slightly lower mortality (hazard ratio=0.85; P=0.091). Conclusions Delivering a BPA through the electronic health record recommending to providers consideration of ICD implantation when the left ventricular ejection fraction is ≤35% improves the rates of electrophysiology referrals and ICD therapy in patients with severe left ventricular dysfunction.


Subject(s)
Cardiomyopathies/therapy , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Electronic Health Records , Reminder Systems , Stroke Volume , Ventricular Dysfunction, Left/therapy , Ventricular Function, Left , Adult , Aged , Aged, 80 and over , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/mortality , Cardiomyopathies/physiopathology , Cause of Death , Female , Humans , Male , Middle Aged , Pennsylvania , Prospective Studies , Referral and Consultation , Risk Assessment , Risk Factors , Treatment Outcome , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/physiopathology , Young Adult
3.
JAMA Cardiol ; 1(8): 945-949, 2016 11 01.
Article in English | MEDLINE | ID: mdl-27541162

ABSTRACT

Importance: Transcatheter aortic valve replacement (TAVR) is now a well-accepted alternative to surgical AVR (SAVR) for patients with symptomatic aortic stenosis at increased operative risk. There is interest in whether TAVR would benefit patients at lower risk. Objective: The Society of Thoracic Surgeons Predicted Risk of Mortality (STS PROM) has trended downward in US TAVR trials and the STS/American College of Cardiology Transcatheter Valve Therapy Registry. We hypothesized that if the Society of Thoracic Surgeons Predicted Risk of Mortality (STS PROM) alone is sufficient to define decreased risk, the contribution to survival based on the degree of invasiveness of the TAVR procedure will decrease, making it more difficult to show improved survival and benefit over SAVR. Design, Setting, and Participants: The CoreValve US Pivotal High Risk Trial was a multicenter, randomized, noninferiority trial. This retrospective analysis evaluated patients who underwent an attempted implant and had an STS PROM of 7% or less. The trial was performed at 45 US sites. Patients had severe aortic stenosis and were at increased surgical risk based on their STS PROM score and other risk factors. Interventions: Eligible patients were randomly assigned (1:1) to self-expanding TAVR or to SAVR. Main Outcomes and Measures: We retrospectively stratified patients by the overall median STS PROM score (7%) and analyzed clinical outcomes and quality of life using the Kansas City Cardiomyopathy Questionnaire in patients with an STS PROM score of 7% or less. Results: The mean (SD) ages were 81.5 (7.6) years for the TAVR group and 81.2 years (6.6) for the SAVR group. A little more than half were men (57.9% in the TAVR group and 55.8% in the SAVR group). Of 750 patients who underwent attempted implantation, 383 (202 TAVR and 181 SAVR) had an STS PROM of 7% or less (median [interquartile range]: TAVR, 5.3% [4.3%-6.1%]; SAVR, 5.3% [4.1%-5.9%]). Two-year all-cause mortality for TAVR vs SAVR was 15.0% (95% CI, 8.9-10.0) vs 26.3% (95% CI, 19.7-33.0) (log rank P = .01). The 2-year rate of stroke for TAVR vs SAVR was 11.3% vs 15.1% (log rank P = .50). Quality of life by the Kansas City Cardiomyopathy Questionnaire summary score showed significant and equivalent increases in both groups at 2 years (mean [SD] TAVR, 20.0 [25.0]; SAVR, 18.6 [23.6]; P = .71; both P < .001 compared with baseline). Medical benefit, defined as alive with a Kansas City Cardiomyopathy Questionnaire summary score of at least 60 and a less than 10-point decrease from baseline, was similar between groups at 2 years (TAVR, 51.0%; SAVR, 44.4%; P = .28). Conclusions and Relevance: Self-expanding TAVR compares favorably with SAVR in high-risk patients with STS PROM scores traditionally considered intermediate risk. Trial Registration: Clinicaltrials.gov Identifier: NCT01240902.


Subject(s)
Aortic Valve Stenosis/therapy , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Quality of Life , Retrospective Studies , Risk , Surgeons , Treatment Outcome
4.
Cell Transplant ; 25(9): 1701-1711, 2016.
Article in English | MEDLINE | ID: mdl-27151378

ABSTRACT

An increasing number of patients have refractory angina despite optimal medical therapy and are without further revascularization options. Preclinical studies indicate that human CD34+ stem cells can stimulate new blood vessel formation in ischemic myocardium, improving perfusion and function. In ACT34-CMI (N = 167), patients treated with autologous CD34+ stem cells had improvements in angina and exercise time at 6 and 12 months compared to placebo; however, the longer-term effects of this treatment are unknown. ACT34 was a phase II randomized, double-blind, placebo-controlled clinical trial comparing placebo, low dose (1 × 105 CD34/kg body weight), and high dose (5 × 105 CD34/kg) using intramyocardial delivery into the ischemic zone following NOGA® mapping. To obtain longer-term safety and efficacy in these patients, we compiled data of major adverse cardiac events (MACE; death, myocardial infarction, acute coronary syndrome, or heart failure hospitalization) up to 24 months as well as angina and quality of life assessments in patients who consented for 24-month follow-up. A total of 167 patients with class III-IV refractory angina were randomized and completed the injection procedure. The low-dose-treated patients had a significant reduction in angina frequency (p = 0.02, 0.035) and improvements in exercise tolerance testing (ETT) time (p = 0.014, 0.017) compared to the placebo group at 6 and 12 months. At 24 months, patients treated with both low-and high-dose CD34+ cells had significant reduction in angina frequency (p = 0.03). At 24 months, there were a total of seven deaths (12.5%) in the control group versus one (1.8%) in the low-dose and two (3.6%) in the high-dose (p = 0.08) groups. At 2 years, MACE occurred at a rate of 33.9%, 21.8%, and 16.2% in control, low-, and high-dose patients, respectively (p = 0.08). Autologous CD34+ cell therapy was associated with persistent improvement in angina at 2 years and a trend for reduction in mortality in no-option patients with refractory angina.


Subject(s)
Angina Pectoris/therapy , Antigens, CD34/metabolism , Cell- and Tissue-Based Therapy/methods , Stem Cells/metabolism , Transplantation, Autologous/methods , Double-Blind Method , Exercise Test , Humans , Myocardium/pathology , Stem Cells/physiology , Treatment Outcome
5.
J Am Coll Cardiol ; 67(22): 2565-74, 2016 Jun 07.
Article in English | MEDLINE | ID: mdl-27050187

ABSTRACT

BACKGROUND: In patients with severe aortic stenosis at increased risk for surgery, self-expanding transcatheter aortic valve replacement (TAVR) is associated with improved 2-year survival compared with surgery. OBJECTIVES: This study sought to determine whether this clinical benefit was sustained over time. METHODS: Patients with severe aortic stenosis deemed at increased risk for surgery by a multidisciplinary heart team were randomized 1:1 to TAVR or open surgical valve replacement (SAVR). Three-year clinical and echocardiographic outcomes were obtained in those patients with an attempted procedure. RESULTS: A total of 797 patients underwent randomization at 45 U.S. centers; 750 patients underwent an attempted procedure. Three-year all-cause mortality or stroke was significantly lower in TAVR patients (37.3% vs. 46.7% in SAVR; p = 0.006). Adverse clinical outcome components were also reduced in TAVR patients compared with SAVR patients, including all-cause mortality (32.9% vs. 39.1%, respectively; p = 0.068), all stroke (12.6% vs. 19.0%, respectively; p = 0.034), and major adverse cardiovascular or cerebrovascular events (40.2% vs. 47.9%, respectively; p = 0.025). At 3 years aortic valve hemodynamics were better with TAVR patients (mean aortic valve gradient 7.62 ± 3.57 mm Hg vs. 11.40 ± 6.81 mm Hg in SAVR; p < 0.001), although moderate or severe residual aortic regurgitation was higher in TAVR patients (6.8% vs. 0.0% in SAVR; p < 0.001). There was no clinical evidence of valve thrombosis in either group. CONCLUSIONS: Patients with severe aortic stenosis at increased risk for surgery had improved 3-year clinical outcomes after TAVR compared with surgery. Aortic valve hemodynamics were more favorable in TAVR patients without differences in structural valve deterioration. (Safety and Efficacy Study of the Medtronic CoreValve(®) System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Stents , Transcatheter Aortic Valve Replacement , Acute Kidney Injury/etiology , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/epidemiology , Aortic Valve Stenosis/mortality , Echocardiography , Endocarditis/etiology , Female , Follow-Up Studies , Hemodynamics , Hospitalization/statistics & numerical data , Humans , Male , Pacemaker, Artificial/statistics & numerical data , Prospective Studies , Reoperation , Stroke/epidemiology , United States/epidemiology
6.
J Am Coll Cardiol ; 66(2): 113-21, 2015 Jul 14.
Article in English | MEDLINE | ID: mdl-26055947

ABSTRACT

BACKGROUND: The U.S. pivotal trial for the self-expanding valve found that among patients with severe aortic stenosis at increased risk for surgery, the 1-year survival rate was 4.9 percentage points higher in patients treated with a self-expanding transcatheter aortic valve bioprosthesis than in those treated with a surgical bioprosthesis. OBJECTIVES: Longer-term clinical outcomes were examined to confirm if this mortality benefit is sustained. METHODS: Patients with severe aortic stenosis who were at increased surgical risk were recruited. Eligible patients were randomly assigned in a 1:1 ratio to transcatheter aortic valve replacement with the self-expanding transcatheter valve (transcatheter aortic valve replacement [TAVR] group) or to aortic valve replacement with a surgical bioprosthesis (surgical group). The 2-year clinical and echocardiographic outcomes were evaluated in these patients. RESULTS: A total of 797 patients underwent randomization at 45 centers in the United States. The rate of 2-year all-cause mortality was significantly lower in the TAVR group (22.2%) than in the surgical group (28.6%; log-rank test p < 0.05) in the as-treated cohort, with an absolute reduction in risk of 6.5 percentage points. Similar results were found in the intention-to-treat cohort (log-rank test p < 0.05). The rate of 2-year death or major stroke was significantly lower in the TAVR group (24.2%) than in the surgical group (32.5%; log-rank test p = 0.01). CONCLUSIONS: In patients with severe aortic stenosis who are at increased surgical risk, the higher rate of survival with a self-expanding TAVR compared with surgery was sustained at 2 years. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).


Subject(s)
Aortic Valve Stenosis/therapy , Aged, 80 and over , Aortic Valve , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Bioprosthesis , Cardiac Catheterization , Echocardiography , Female , Humans , Male , Stroke/etiology , Treatment Outcome
7.
J Thorac Cardiovasc Surg ; 148(6): 2869-76.e1-7, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25152474

ABSTRACT

OBJECTIVES: The CoreValve Extreme Risk US Pivotal Trial enrolled patients with symptomatic severe aortic stenosis deemed unsuitable for surgical aortic valve replacement. Implants were attempted using transfemoral access (n = 489) or an alternative access (n = 150). In present analysis, we sought to examine the safety and efficacy of CoreValve transcatheter aortic valve replacement using alternative access. METHODS: The present study included 150 patients with prohibitive iliofemoral anatomy who were treated with the CoreValve transcatheter heart valve delivered by way of the subclavian artery (n = 70) or a direct aortic approach (n = 80). The echocardiograms were read by an independent core laboratory. The primary endpoint was all-cause mortality or major stroke at 12 months. RESULTS: The preoperative aortic valve area was 0.72 ± 0.27 cm(2) and mean aortic valve gradient was 49.5 ± 17.0 mm Hg. After the transcatheter aortic valve replacement, the effective aortic valve area was 1.82 ± 0.64 cm(2) at 1 month and 1.85 ± 0.51 cm(2) at 12 months. The mean aortic valve gradient was 9.7 ± 5.8 mm Hg at 30 days and 9.5 ± 5.7 mm Hg at 12 months. The death or major stroke rate was 15.3% at 30 days and 39.4% at 12 months. The individual rate of all-cause mortality and major stroke was 11.3% and 7.5% at 30 days and 36.0% and 9.1% at 12 months. CONCLUSIONS: These data demonstrate that the CoreValve transcatheter heart valve delivered by an alternative access provides a suitable alternative for treatment of extreme risk patients with symptomatic severe aortic stenosis, who have prohibitive iliofemoral anatomy and no surgical options.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/physiopathology , Cardiac Catheterization/instrumentation , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aorta , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , Prospective Studies , Prosthesis Design , Severity of Illness Index , Stroke/etiology , Subclavian Artery , Time Factors , Treatment Outcome , United States
8.
Pharmacotherapy ; 27(5): 647-56, 2007 May.
Article in English | MEDLINE | ID: mdl-17461699

ABSTRACT

OBJECTIVE: To compare clinical outcomes and glycoprotein IIb-IIIa inhibitor use in patients undergoing percutaneous coronary intervention (PCI) who received bivalirudin or unfractionated heparin (UFH) in a real-world setting. DESIGN: Retrospective cohort analysis. SETTING: University-affiliated medical center. PATIENTS: One thousand seventy-five adult patients who underwent PCI and received either bivalirudin (539 patients) or UFH (536 patients) from April 1, 2003-April 1, 2004. MEASUREMENT AND MAIN RESULTS: Patient data on demographics, comorbidities, laboratory values, and reports of radiologic examinations, cardiac catheterizations, and discharge summaries were obtained. Outcomes evaluated included rates of in-hospital mortality, myocardial infarction, revascularization, and length of stay (LOS), as well as Randomized Evaluation of PCI Linking Angiomax to Reduced Clinical Events (REPLACE-2) and Thrombosis in Myocardial Infarction (TIMI) bleeding categorization. Bivalirudin use was associated with a significant reduction in TIMI major (5.0% vs 9.7%, p=0.003), REPLACE-2 major (5.4% vs 12.9%, p<0.001), and TIMI minor (1.7% vs 6%, p<0.001) bleeding complications compared with UFH use. Significantly fewer patients in the bivalirudin group received glycoprotein IIb-IIIa inhibitors (27.3% vs 62.7%, p<0.001). Patients receiving bivalirudin had significantly fewer myocardial infarctions after catheterization (10.7% [40/375] vs 18.0% [51/284], p=0.007). No differences were noted in mortality and revascularization rates between groups. A shortened LOS was observed in the bivalirudin group. CONCLUSIONS: This real-world analysis that included high-risk patients provides further evidence that bivalirudin is an attractive alternative to UFH because of a decrease in bleeding events without compromising efficacy.


Subject(s)
Angioplasty, Balloon, Coronary , Anticoagulants/therapeutic use , Heparin/therapeutic use , Peptide Fragments/therapeutic use , Aged , Anticoagulants/adverse effects , Cohort Studies , Female , Hemorrhage/chemically induced , Heparin/adverse effects , Hirudins/adverse effects , Hospitals, University , Humans , Length of Stay , Logistic Models , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/drug therapy , Myocardial Revascularization , Peptide Fragments/adverse effects , Platelet Aggregation Inhibitors/therapeutic use , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Recombinant Proteins/adverse effects , Recombinant Proteins/therapeutic use , Retrospective Studies , Risk Factors , Thrombosis , Treatment Outcome
9.
Am J Physiol Heart Circ Physiol ; 282(6): H2076-83, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12003814

ABSTRACT

Transgenic mice are widely used to study cardiac function, but strain-dependent differences in autonomic nervous system activity (ANSA) have not been explored. We compared 1) short-term pharmacological responses of cardiac rhythm in FVB vs. C57Black6/SV129 wild-type mice and 2) long-term physiological dynamics of cardiac rhythm and survival in tumor necrosis factor (TNF)-alpha transgenic mice with heart failure (TNF-alpha mice) on defined backgrounds. Ambulatory telemetry electrocardiographic recordings and response to saline, adrenergic, and cholinergic agents were examined in FVB and C57Black6/SV129 mice. In FVB mice, baseline heart rate (HR) was higher and did not change after injection of isoproterenol or atropine but decreased with propranolol. In C57Black6/SV129 mice, HR did not change with propranolol but increased with isoproterenol or atropine. Mean HR, but not indexes of HR variability, was an excellent predictor of response to autonomic agents. The proportion of surviving animals was higher in TNF-alpha mice on an FVB background than on a mixed FVB/C57Black6 background. The homeostatic states of ANSA are strain specific, which can explain the interstrain differences in mean HR, pharmacological responses, and survival of animals with congestive heart failure. Strain-specific differences should be considered in selecting the strains of mice used for transgenic and gene targeting experiments.


Subject(s)
Autonomic Nervous System/physiology , Genetic Predisposition to Disease , Heart Failure/genetics , Adrenergic alpha-Antagonists/pharmacology , Adrenergic beta-Agonists/pharmacology , Adrenergic beta-Antagonists/pharmacology , Animals , Atropine/pharmacology , Circadian Rhythm , Female , Heart Failure/mortality , Heart Failure/physiopathology , Heart Rate/drug effects , Isoproterenol/pharmacology , Male , Methoxamine/pharmacology , Mice , Mice, Inbred C57BL , Mice, Transgenic , Propranolol/pharmacology , Receptors, Adrenergic, alpha/physiology , Receptors, Adrenergic, alpha-1/drug effects , Receptors, Adrenergic, alpha-1/physiology , Species Specificity , Survival Rate , Tumor Necrosis Factor-alpha/genetics , Tumor Necrosis Factor-alpha/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...