Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
Add more filters










Publication year range
1.
Angew Chem Int Ed Engl ; 62(22): e202219024, 2023 05 22.
Article in English | MEDLINE | ID: mdl-36935352

ABSTRACT

We report on a controllable and specific functionalisation route for graphene field-effect transistors (GFETs) for the recognition of small physiologically active molecules. Key element is the noncovalent functionalisation of the graphene surface with perylene bisimide (PBI) molecules directly on the growth substrate. This Functional Layer Transfer enables the homogeneous self-assembly of PBI molecules on graphene, onto which antibodies are subsequently immobilised. The sensor surface was characterised by atomic force microscopy, Raman spectroscopy and electrical measurements, showing superior performance over conventional functionalisation after transfer. Specific sensing of small molecules was realised by monitoring the electrical property changes of functionalised GFET devices upon the application of methamphetamine and cortisol. The concentration dependent electrical response of our sensors was determined down to a concentration of 300 ng ml-1 for methamphetamine.


Subject(s)
Graphite , Graphite/chemistry , Transistors, Electronic , Biomarkers , Antibodies , Microscopy, Atomic Force
2.
Acute Crit Care ; 38(1): 95-103, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36935538

ABSTRACT

BACKGROUND: In patients with severe trauma, the diagnosis of acute kidney injury (AKI) is important because it is a predictive factor for poor prognosis and can affect patient care. The diagnosis and staging of AKI are based on change in serum creatinine (SCr) levels from baseline. However, baseline creatinine levels in patients with traumatic injuries are often unknown, making the diagnosis of AKI in trauma patients difficult. This study aimed to enhance the accuracy of AKI diagnosis in trauma patients by presenting an appropriate reference creatinine estimate (RCE). METHODS: We reviewed adult patients with severe trauma requiring intensive care unit admission between 2015 and 2019 (n=3,228) at a single regional trauma center in South Korea. AKI was diagnosed based on the current guideline published by the Kidney Disease: Improving Global Outcomes organization. AKI was determined using the following RCEs: estimated SCr75-modification of diet in renal disease (MDRD), trauma MDRD (TMDRD), admission creatinine level, and first-day creatinine nadir. We assessed inclusivity, prognostic ability, and incrementality using the different RCEs. RESULTS: The incidence of AKI varied from 15% to 46% according to the RCE used. The receiver operating characteristic curve of TMDRD used to predict mortality and the need for renal replacement therapy (RRT) had the highest value and was statistically significant (0.797, P<0.001; 0.890, P=0.002, respectively). In addition, the use of TMDRD resulted in a mortality prognostic ability and the need for RRT was incremental with AKI stage. CONCLUSIONS: In this study, TMDRD was feasible as a RCE, resulting in optimal post-traumatic AKI diagnosis and prognosis.

3.
Sensors (Basel) ; 24(1)2023 Dec 26.
Article in English | MEDLINE | ID: mdl-38202994

ABSTRACT

Amputees typically experience changes in residual limb volume in their daily lives. It causes an uncomfortable fit of the socket by applying high pressure on the sensitive area of the residual limb or by loosening the socket. In this study, we developed a transfemoral prosthetic socket for above-the-knee amputees that ensures a good socket fit by maintaining uniform and constant contact pressure despite volume changes in the residual limb. The socket has two air bladders in the posterior femoral region, and the pneumatic controller is located on the tibia of the prosthesis. The pneumatic system aims to minimize unstable fitting of the socket and improve walking performance by inflating or deflating the air bladder. The developed socket autonomously maintains the air pressure inside the prosthetic socket at a steady-state error of 3 mmHg or less by adjusting the amount of air in the air bladder via closed-loop control. In the clinical trial, amputee participants walked on flat and inclined surfaces. The displacement between the residual limb and socket during the gait cycle was reduced by up to 33.4% after air injection into the socket. The inflatable bladder increased the knee flexion angle on the affected side, resulting in increased stride length and gait velocity. The pneumatic socket provides a stable and comfortable walking experience not only when walking on flat ground but also on slopes.


Subject(s)
Amputees , Artificial Limbs , Humans , Gait , Walking , Extremities
4.
Nature ; 606(7915): 663-673, 2022 06.
Article in English | MEDLINE | ID: mdl-35732761

ABSTRACT

Non-volatile magnetic random-access memories (MRAMs), such as spin-transfer torque MRAM and next-generation spin-orbit torque MRAM, are emerging as key to enabling low-power technologies, which are expected to spread over large markets from embedded memories to the Internet of Things. Concurrently, the development and performances of devices based on two-dimensional van der Waals heterostructures bring ultracompact multilayer compounds with unprecedented material-engineering capabilities. Here we provide an overview of the current developments and challenges in regard to MRAM, and then outline the opportunities that can arise by incorporating two-dimensional material technologies. We highlight the fundamental properties of atomically smooth interfaces, the reduced material intermixing, the crystal symmetries and the proximity effects as the key drivers for possible disruptive improvements for MRAM at advanced technology nodes.

5.
Nature ; 601(7892): 211-216, 2022 01.
Article in English | MEDLINE | ID: mdl-35022590

ABSTRACT

Implementations of artificial neural networks that borrow analogue techniques could potentially offer low-power alternatives to fully digital approaches1-3. One notable example is in-memory computing based on crossbar arrays of non-volatile memories4-7 that execute, in an analogue manner, multiply-accumulate operations prevalent in artificial neural networks. Various non-volatile memories-including resistive memory8-13, phase-change memory14,15 and flash memory16-19-have been used for such approaches. However, it remains challenging to develop a crossbar array of spin-transfer-torque magnetoresistive random-access memory (MRAM)20-22,  despite the technology's practical advantages such as endurance and large-scale commercialization5. The difficulty stems from the low resistance of MRAM, which would result in large power consumption in a conventional crossbar array that uses current summation for analogue multiply-accumulate operations. Here we report a 64 × 64 crossbar array based on MRAM cells that overcomes the low-resistance issue with an architecture that uses resistance summation for analogue multiply-accumulate operations. The array is integrated with readout electronics in 28-nanometre complementary metal-oxide-semiconductor technology. Using this array, a two-layer perceptron is implemented to classify 10,000 Modified National Institute of Standards and Technology digits with an accuracy of 93.23 per cent (software baseline: 95.24 per cent). In an emulation of a deeper, eight-layer Visual Geometry Group-8 neural network with measured errors, the classification accuracy improves to 98.86 per cent (software baseline: 99.28 per cent). We also use the array to implement a single layer in a ten-layer neural network to realize face detection with an accuracy of 93.4 per cent.

6.
Sensors (Basel) ; 21(2)2021 Jan 07.
Article in English | MEDLINE | ID: mdl-33430443

ABSTRACT

We developed an integrated PCR system that performs automated sample preparation and fast polymerase chain reaction (PCR) for application in point-of care (POC) testing. This system is assembled from inexpensive 3D-printing parts, off-the-shelf electronics and motors. Molecular detection requires a series of procedures including sample preparation, amplification, and fluorescence intensity analysis. The system can perform automated DNA sample preparation (extraction, separation and purification) in ≤5 min. The variance of the automated sample preparation was clearly lower than that achieved using manual DNA extraction. Fast thermal ramp cycles were generated by a customized thermocycler designed to automatically transport samples between heating and cooling blocks. Despite the large sample volume (50 µL), rapid two-step PCR amplification completed 40 cycles in ≤13.8 min. Variations in fluorescence intensity were measured by analyzing fluorescence images. As proof of concept of this system, we demonstrated the rapid DNA detection of pathogenic bacteria. We also compared the sensitivity of this system with that of a commercial device during the automated extraction and fast PCR of Salmonella bacteria.


Subject(s)
Bacterial Infections , Point-of-Care Systems , Bacteria/genetics , DNA , Humans , Polymerase Chain Reaction
7.
Sensors (Basel) ; 21(2)2021 Jan 08.
Article in English | MEDLINE | ID: mdl-33435553

ABSTRACT

Typically, the actual volume of the residual limb changes over time. This causes the prosthesis to not fit, and then pain and skin disease. In this study, a prosthetic socket was developed to compensate for the volume change of the residual limb. Using an inflatable air bladder, the proposed socket monitors the pressure in the socket and keeps the pressure distribution uniform and constant while walking. The socket has three air bladders on anterior and posterior tibia areas, a latching type 3-way pneumatic valve and a portable control device. In the paper, the mechanical properties of the air bladder were investigated, and the electromagnetic analysis was performed to design the pneumatic valve. The controller is based on a hysteresis control algorithm with a closed loop, which keeps the pressure in the socket close to the initial set point over a long period of time. In experiments, the proposed prosthesis was tested through the gait simulator that can imitate a human's gait cycle. The active volume compensation of the socket was successfully verified during repetitive gait cycle using the weight loads of 50, 70, and 90 kg and the residual limb model with a variety of volumes. It was confirmed that the pressure of the residual limb recovered to the initial state through the active control. The pressure inside the socket had a steady state error of less than 0.75% even if the volume of the residual limb was changed from -7% to +7%.


Subject(s)
Amputation Stumps , Artificial Limbs , Humans , Lower Extremity , Prosthesis Design , Tibia
8.
Research (Wash D C) ; 2020: 8748602, 2020.
Article in English | MEDLINE | ID: mdl-32766550

ABSTRACT

The unique properties and atomic thickness of two-dimensional (2D) materials enable smaller and better nanoelectromechanical sensors with novel functionalities. During the last decade, many studies have successfully shown the feasibility of using suspended membranes of 2D materials in pressure sensors, microphones, accelerometers, and mass and gas sensors. In this review, we explain the different sensing concepts and give an overview of the relevant material properties, fabrication routes, and device operation principles. Finally, we discuss sensor readout and integration methods and provide comparisons against the state of the art to show both the challenges and promises of 2D material-based nanoelectromechanical sensing.

10.
ACS Omega ; 5(11): 5959-5963, 2020 Mar 24.
Article in English | MEDLINE | ID: mdl-32226876

ABSTRACT

Two-dimensional materials (2DMs) have high potential in gas sensing, due to their large surface-to-volume ratio. However, most sensors based on 2DMs suffer from the lack of a steady state during gas exposure, hampering sensor calibration. Here, we demonstrate that analysis of the time differential of the signal output enables the calibration of chemiresistors based on platinum or tungsten diselenide (PtSe2, WSe2) and molybdenum disulfide (MoS2), which present nonstationary behavior. 2DMs are synthesized by thermally assisted conversion of predeposited metals on a silicon/silicon dioxide substrate and therefore are integrable with standard complementary metal-oxide semiconductor (CMOS) technology. We analyze the behavior of the sensors at room temperature toward nitrogen dioxide (NO2) in a narrow range from 0.1 to 1 ppm. This study overcomes the problem of the absence of steady-state signals in 2DM gas sensors and thus facilitates their usage in this highly important application.

11.
Sensors (Basel) ; 19(18)2019 Sep 06.
Article in English | MEDLINE | ID: mdl-31500195

ABSTRACT

A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0-50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.

12.
Sensors (Basel) ; 18(7)2018 Jul 14.
Article in English | MEDLINE | ID: mdl-30011898

ABSTRACT

A disposable potentiometric sensor was newly developed for the amplification-coupled detection of nucleic acids. The hydrogen-ion is generally released during isothermal amplification of nucleic acids. The surface potential on the oxide-functionalized electrode of the extended gate was directly measured using full electrical circuits with the commercial metal-oxide semiconductor field-effect transistors (MOSFETs) and ring oscillator components, which resulted in cost-effective, portable and scalable real-time nucleic acid analysis. The current-starved ring oscillator changes surface potential to its frequency depending on the square of the variation in pH with a high signal-to-noise ratio during isothermal amplification. The device achieves a conversion rate of 20.5 kHz/mV and a detection resolution of 200 µV for the surface potential. It is demonstrated that the sensor successfully monitors in real-time isothermal amplification of the extracted nucleic acids from Salmonella pathogenic bacteria. The in situ variations in the frequency of the pH-sensitive sensor were compared with the results of both a conventional optical device and pH-meter during isothermal amplification.


Subject(s)
Nucleic Acid Amplification Techniques , Nucleic Acids/analysis , Potentiometry/instrumentation , Temperature , Electrodes , Hydrogen-Ion Concentration , Nucleic Acids/isolation & purification , Salmonella/genetics , Semiconductors
13.
Biosens Bioelectron ; 88: 153-158, 2017 Feb 15.
Article in English | MEDLINE | ID: mdl-27503409

ABSTRACT

Relocation mechanisms of the circulating tumor cells (CTCs) from the primary site to the secondary site through the blood vessel network cause tumor metastasis. Despite of the importance to diagnose the cancer metastasis by CTCs, still it is formidable challenge to use in the clinical purpose because of the rarity and the heterogeneity of CTCs in the cancer patient's peripheral blood sample. In this study we have developed magnetic force gradient based microfluidic chip (Mag-Gradient Chip) for isolating the total number of CTCs in the sample and characterizing the state of CTCs simultaneously with respect to the epithelial cell adhesion molecule (EpCAM) expression level. We have synthesized magnetic nanoparticles (MNPs) using hydrothermal method and functionalized anti-EpCAM on their surface for the specific binding with CTCs. The Mag-Gradient Chip designed to isolate and classify the CTCs by isolating at the different location in the chip using magnetic force differences depending on the EpCAM expression level. We observed 95.7% of EpCAM positive and 79.3% of EpCAM negative CTCs isolated in the Mag-Gradient Chip. At the same time, the 71.3% of isolated EpCAM positive CTCs were isolated at the first half area whereas the 76.9% of EpCAM negative CTCs were collected at the latter half area. The Mag-Gradient Chip can isolate the 3ml of heterogeneous CTCs sample in 1h with high isolating yield. The EpCAM expression level dose not means essential condition of the metastatic CTCs, but the Mag-Gradient Chip can shorten the date to diagnose the cancer metastasis in clinic.


Subject(s)
Epithelial Cell Adhesion Molecule/analysis , Immunomagnetic Separation/instrumentation , Lab-On-A-Chip Devices , Neoplastic Cells, Circulating/pathology , Antibodies, Immobilized/chemistry , Cell Line, Tumor , Equipment Design , Humans , Magnetics/instrumentation , Magnetite Nanoparticles/chemistry
14.
ACS Nano ; 10(10): 9550-9558, 2016 Oct 25.
Article in English | MEDLINE | ID: mdl-27661979

ABSTRACT

Layered two-dimensional (2D) materials display great potential for a range of applications, particularly in electronics. We report the large-scale synthesis of thin films of platinum diselenide (PtSe2), a thus far scarcely investigated transition metal dichalcogenide. Importantly, the synthesis by thermally assisted conversion is performed at 400 °C, representing a breakthrough for the direct integration of this material with silicon (Si) technology. Besides the thorough characterization of this 2D material, we demonstrate its promise for applications in high-performance gas sensing with extremely short response and recovery times observed due to the 2D nature of the films. Furthermore, we realized vertically stacked heterostructures of PtSe2 on Si which act as both photodiodes and photovoltaic cells. Thus, this study establishes PtSe2 as a potential candidate for next-generation sensors and (opto-)electronic devices, using fabrication protocols compatible with established Si technologies.

15.
Nat Commun ; 6: 8563, 2015 Oct 15.
Article in English | MEDLINE | ID: mdl-26469634

ABSTRACT

Few-layer black phosphorus (BP) is a new two-dimensional material which is of great interest for applications, mainly in electronics. However, its lack of environmental stability severely limits its synthesis and processing. Here we demonstrate that high-quality, few-layer BP nanosheets, with controllable size and observable photoluminescence, can be produced in large quantities by liquid phase exfoliation under ambient conditions in solvents such as N-cyclohexyl-2-pyrrolidone (CHP). Nanosheets are surprisingly stable in CHP, probably due to the solvation shell protecting the nanosheets from reacting with water or oxygen. Experiments, supported by simulations, show reactions to occur only at the nanosheet edge, with the rate and extent of the reaction dependent on the water/oxygen content. We demonstrate that liquid-exfoliated BP nanosheets are potentially useful in a range of applications from ultrafast saturable absorbers to gas sensors to fillers for composite reinforcement.

16.
Sci Rep ; 4: 7374, 2014 Dec 09.
Article in English | MEDLINE | ID: mdl-25487822

ABSTRACT

Reliable chemical vapour deposition (CVD) of transition metal dichalcogenides (TMDs) is currently a highly pressing research field, as numerous potential applications rely on the production of high quality films on a macroscopic scale. Here, we show the use of liquid phase exfoliated nanosheets and patterned sputter deposited layers as solid precursors for chemical vapour deposition. TMD monolayers were realized using a close proximity precursor supply in a CVD microreactor setup. A model describing the growth mechanism, which is capable of producing TMD monolayers on arbitrary substrates, is presented. Raman spectroscopy, photoluminescence, X-ray photoelectron spectroscopy, atomic force microscopy, transmission electron microscopy, scanning electron microscopy and electrical transport measurements reveal the high quality of the TMD samples produced. Furthermore, through patterning of the precursor supply, we achieve patterned growth of monolayer TMDs in defined locations, which could be adapted for the facile production of electronic device components.

17.
Bioorg Med Chem ; 22(17): 4587-96, 2014 Sep 01.
Article in English | MEDLINE | ID: mdl-25127461

ABSTRACT

5-HT7 receptor (5-HT7R) is a promising target for the treatment of depression and neuropathic pain. 5-HT7R antagonists exhibited antidepressant effects, while the agonists produced strong anti-hyperalgesic effects. In our efforts to discover selective 5-HT7R antagonists or agonists, N-biphenylylmethyl 2-methoxyphenylpiperazinylalkanamides 1 were designed, synthesized, and biologically evaluated against 5-HT7R. Among the synthesized compounds, N-2'-chlorobiphenylylmethyl 2-methoxyphenylpiperazinylpentanamide 1-8 showed the best binding affinity with a Ki value of 8.69nM and it was verified as a novel antagonist according to functional assays. The compound 1-8 was very selective over 5-HT1DR, 5-HT2AR, 5-HT3R, 5-HT5AR and 5-HT6R and moderately selective over 5-HT1AR, 5-HT1BR and 5-HT2CR. The novel 5-HT7R antagonist 1-8 exhibited an antidepressant effect at a dose of 25mg/kg in the forced swimming test in mice and showed a U-shaped dose-response curve which typically appears in 5-HT7R antagonists such as SB-269970 and lurasidone.


Subject(s)
Amides/pharmacology , Antidepressive Agents/pharmacology , Depression/drug therapy , Piperazines/pharmacology , Receptors, Serotonin/metabolism , Amides/administration & dosage , Amides/chemistry , Animals , Antidepressive Agents/administration & dosage , Antidepressive Agents/chemistry , HEK293 Cells , Humans , Injections, Intraperitoneal , Male , Mice , Mice, Inbred ICR , Piperazines/administration & dosage , Piperazines/chemistry , Swimming
18.
ChemMedChem ; 8(11): 1855-64, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24039134

ABSTRACT

The 5-HT7 receptor (5-HT7 R) is a promising therapeutic target for the treatment of depression and neuropathic pain. The 5-HT7 R antagonist SB-269970 exhibited antidepressant-like activity, whereas systemic administration of the 5-HT7 R agonist AS-19 significantly inhibited mechanical hypersensitivity and thermal hyperalgesia. In our efforts to discover selective 5-HT7 R antagonists or agonists, aryl biphenyl-3-ylmethylpiperazines were designed, synthesized, and biologically evaluated against the 5-HT7 R. Among the synthesized compounds, 1-([2'-methoxy-(1,1'-biphenyl)-3-yl]methyl)-4-(2-methoxyphenyl)piperazine (28) was the best binder to the 5-HT7 R (pKi =7.83), and its antagonistic property was confirmed by functional assays. The selectivity profile of compound 28 was also recorded for the 5-HT7 R over other serotonin receptor subtypes, such as 5-HT1 R, 5-HT2 R, 5-HT3 R, and 5-HT6 R. In a molecular modeling study, the 2-methoxyphenyl moiety attached to the piperazine ring of compound 28 was proposed to be essential for the antagonistic function.


Subject(s)
Biphenyl Compounds/chemistry , Drug Design , Phenols/chemistry , Phenols/pharmacology , Piperazines/chemistry , Receptors, Serotonin/chemistry , Sulfonamides/chemistry , Sulfonamides/pharmacology , Biphenyl Compounds/pharmacology , Ligands , Models, Molecular , Piperazines/chemical synthesis , Piperazines/pharmacology , Protein Binding/drug effects , Serotonin Antagonists/chemical synthesis , Serotonin Antagonists/chemistry , Serotonin Antagonists/pharmacology , Structure-Activity Relationship
19.
Adv Mater ; 25(46): 6699-702, 2013 Dec 10.
Article in English | MEDLINE | ID: mdl-24027114

ABSTRACT

High-performance sensors based on molybdenum disulfide (MoS2 ) grown by sulfurization of sputtered molybdenum layers are presented. Using a simple integration scheme, it is found that the electrical conductivity of MoS2 films is highly sensitive to NH3 adsorption, consistent with n-type semiconducting behavior. A sensitivity of 300 ppb at room temperature is achieved, showing the high potential of 2D transition metal-dichalcogenides for sensing.

20.
Nano Lett ; 13(5): 2182-8, 2013 May 08.
Article in English | MEDLINE | ID: mdl-23547771

ABSTRACT

We report the manufacture of novel graphene diode sensors (GDS), which are composed of monolayer graphene on silicon substrates, allowing exposure to liquids and gases. Parameter changes in the diode can be correlated with charge transfer from various adsorbates. The GDS allows for investigation and tuning of extrinsic doping of graphene with great reliability. The demonstrated recovery and long-term stability qualifies the GDS as a new platform for gas, environmental, and biocompatible sensors.

SELECTION OF CITATIONS
SEARCH DETAIL
...