Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 61
Filter
1.
Med Phys ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38828894

ABSTRACT

BACKGROUND: Previous study proposed a method to measure linear energy transfer (LET) at specific points using the quenching magnitude of thin film solar cells. This study was conducted to propose a more advanced method for measuring the LET distribution. PURPOSE: This study focuses on evaluating the feasibility of estimating the proton LET distribution in proton therapy. The feasibility of measuring the proton LET and dose distribution simultaneously using a single-channel configuration comprising two solar cells with distinct quenching constants is investigated with the objective of paving the way for enhanced proton therapy dosimetry. METHODS: Two solar cells with different quenching constants were used to estimate the proton LET distribution. Detector characteristics (e.g., dose linearity and dose-rate dependency) of the solar cells were evaluated to assess their suitability for dosimetry applications. First, using a reference beam condition, the quenching constants of the two solar cells were determined according to the modified Birks equation. The signal ratios of the two solar cells were then evaluated according to proton LET in relation to the estimated quenching constants. The proton LET distributions of six test beams were obtained by measuring the signal ratios of the two solar cells at each depth, and the ratios were evaluated by comparing them with those calculated by Monte Carlo simulation. RESULTS: The detector characterization of the two solar cells including dose linearity and dose-rate dependence affirmed their suitability for use in dosimetry applications. The maximum difference between the LET measured using the two solar cells and that calculated by Monte Carlo simulation was 2.34 keV/µm. In the case of the dose distribution measured using the method proposed in this study, the maximum difference between range measured using the proposed method and that measured using a multilayered ionization chamber was 0.7 mm. The expected accuracy of simultaneous LET and dose distribution measurement using the method proposed in this study were estimated to be 3.82%. The signal ratios of the two solar cells, which are related to quenching constants, demonstrated the feasibility of measuring LET and dose distribution simultaneously. CONCLUSION: The feasibility of measuring proton LET and dose distribution simultaneously using two solar cells with different quenching constants was demonstrated. Although the method proposed in this study was evaluated using a single channel by varying the measuring depth, the results suggest that the proton LET and dose distribution can be simultaneously measured if the detector is configured in a multichannel form. We believe that the results presented in this study provide the envisioned transition to a multichannel configuration, with the promise of substantially advancing proton therapy's accuracy and efficacy in cancer treatment.

2.
Med Phys ; 51(3): 1985-1996, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37722712

ABSTRACT

BACKGROUND: In proton therapy, a highly steep distal dose penumbra can be utilized for dose conformity, given the Bragg peak characteristic of protons. However, the location of the Bragg peak in patients (i.e., the beam range) is very sensitive to range uncertainty. Even a small shift of beam range can produce a significant variation of delivered dose to tumor and normal tissues, thus degrading treatment quality and threatening patient safety. This range uncertainty issue, therefore, is one of the important aspects to be managed in proton therapy. PURPOSE: For better management of range uncertainty, range verification has been widely studied, and prompt gamma imaging (PGI) is considered one of the promising methods in that effort. In this context, a PGI system named the gamma electron vertex imaging (GEVI) system was developed and recently upgraded for application to pencil-beam scanning (PBS) proton therapy. Here, we report the first experimental results using the therapeutic spot scanning proton beams. METHODS: A homogeneous slab phantom and an anthropomorphic phantom were employed. Spherical and cubic planning target volumes (PTVs) were defined. Various range shift scenarios were introduced. Prompt gamma (PG) measurement was synchronized with beam irradiation. The measured PG distributions were aggregated to improve the PG statistics. The range shift was estimated based on the relative change of the centroid in the measured PG distribution. The estimated range shifts were analyzed by range shift mapping, confidence interval (CI) estimation, and statistical hypothesis testing. RESULTS: The range shift mapping results showed an obvious measured range shift tendency following the true shift values. However, some fluctuations were found for spots that had still-low PG statistics after spot aggregation. The 99% CI distributions showed clearly distributed range shift measurement data. The overall accuracy and precision for all investigated scenarios were 0.36 and 0.20 mm, respectively. The results of one-sample t-tests confirmed that every shift scenario could be observed up to 1 mm of shift. The ANOVA results proved that the measured range shift data could be discriminated from one another, except for 16 (of 138) comparison cases having 1-2 mm shift differences. CONCLUSIONS: This study demonstrated the feasibility of the GEVI system for measurement of range shift in spot scanning proton therapy. Our experimental results showed that the proton beam can be measured up to 1 mm of range shift with high accuracy and precision. We believe that the GEVI system is one of the most promising PGI systems for in vivo range verification. Further research for application to more various cases and patient treatments is planned.


Subject(s)
Proton Therapy , Humans , Proton Therapy/methods , Electrons , Protons , Radiotherapy Planning, Computer-Assisted/methods , Diagnostic Imaging , Phantoms, Imaging , Radiotherapy Dosage
3.
Cancers (Basel) ; 15(13)2023 Jul 02.
Article in English | MEDLINE | ID: mdl-37444573

ABSTRACT

(1) In this study, we developed a deep learning (DL) model that can be used to predict late bladder toxicity. (2) We collected data obtained from 281 uterine cervical cancer patients who underwent definitive radiation therapy. The DL model was trained using 16 features, including patient, tumor, treatment, and dose parameters, and its performance was compared with that of a multivariable logistic regression model using the following metrics: accuracy, prediction, recall, F1-score, and area under the receiver operating characteristic curve (AUROC). In addition, permutation feature importance was calculated to interpret the DL model for each feature, and the lightweight DL model was designed to focus on the top five important features. (3) The DL model outperformed the multivariable logistic regression model on our dataset. It achieved an F1-score of 0.76 and an AUROC of 0.81, while the corresponding values for the multivariable logistic regression were 0.14 and 0.43, respectively. The DL model identified the doses for the most exposed 2 cc volume of the bladder (BD2cc) as the most important feature, followed by BD5cc and the ICRU bladder point. In the case of the lightweight DL model, the F-score and AUROC were 0.90 and 0.91, respectively. (4) The DL models exhibited superior performance in predicting late bladder toxicity compared with the statistical method. Through the interpretation of the model, it further emphasized its potential for improving patient outcomes and minimizing treatment-related complications with a high level of reliability.

4.
Med Phys ; 50(4): 2402-2416, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36583513

ABSTRACT

PURPOSE: Various dosimeters have been proposed for skin dosimetry in electron radiotherapy. However, one main drawback of these skin dosimeters is their lack of flexibility, which could make accurate dose measurements challenging due to air gaps between a curved patient surface and dosimeter. Therefore, the purpose of this study is to suggest a novel flexible skin dosimeter based on a thin-film copper indium gallium selenide (CIGS) solar cell, and to evaluate its dosimetric characteristics. METHODS: The CIGS solar cell dosimeter consisted of (a) a customized thin-film CIGS solar cell and (b) a data acquisition (DAQ) system. The CIGS solar cell with a thickness of 0.33 mm was customized to a size of 10 × 10 mm2 . This customized solar cell plays a role in converting therapeutic electron radiation into electrical signals. The DAQ system was composed of a voltage amplifier with a gain of 1000, a voltage input module, a DAQ chassis, and an in-house software. This system converted the electrical analog signals (from solar cell) to digital signals with a sampling rate of ≤50 kHz and then quantified/visualized the digital signals in real time. We quantified the linearity/ sampling rate effect/dose rate dependence/energy dependence/field size output factor/reproducibility/curvature/bending recoverability/angular dependence of the CIGS solar cell dosimeter in therapeutic electron beams. To evaluate clinical feasibility, we measured the skin point doses by attaching the CIGS solar cell to an anthropomorphic phantom surface (for forehead, mouth, and thorax). The CIGS-measured doses were compared with calculated doses (by treatment planning system) and measured doses (by optically stimulated luminescent dosimeter). RESULTS: The normalized signals of the solar cell dosimeter increased linearly as the delivered dose increased. The gradient of the linearly fitted line was 1.00 with an R-square of 0.9999. The sampling rates (2, 10, and 50 kHz) of the solar cell dosimeter showed good performance even at low doses (<50 cGy). The solar cell dosimeter exhibited dose rate independence within 1% and energy independence within 3% error margins. The signals of the solar cell dosimeter were similar (<1%) when penetrating the same side of the CIGS cell regardless of the rotation angle of the solar cell. The field size output factor measured by the solar cell dosimeter was comparable to that measured by the ion chamber. The solar cell signals were similar between the baseline (week 1) and the last time point (week 4). Our detector showed curvature independence within 1.8% (curvatures of <0.10 mm- ) and bending recovery (curvature of 0.10 mm-1 ). The differences between measured doses (CIGS solar cell dosimeter vs. optically stimulated luminescent dosimeter) were 7.1%, 9.6%, and 1.0% for forehead, mouth, and thorax, respectively. CONCLUSION: We present the construction of a flexible skin dosimeter based on a CIGS solar cell. Our findings demonstrate that the CIGS solar cell has a potential to be a novel flexible skin dosimeter for electron radiotherapy. Moreover, this dosimeter is manufactured with low cost and can be easily customized to various size/shape, which represents advantages over other dosimeters.


Subject(s)
Copper , Radiation Dosimeters , Humans , Indium , Electrons , Reproducibility of Results , Radiometry
5.
Med Phys ; 50(2): 1194-1204, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36135795

ABSTRACT

PURPOSE: The amount of luminescent light detected in a scintillator is reduced with increased proton linear energy transfer (LET) despite receiving the same proton dose, through a phenomenon called quenching. This study evaluated the ability of a solar cell coated with scintillating powder (SC-SP) to measure therapeutic proton LET by measuring the quenching effect of the scintillating powder using a solar cell while simultaneously measuring the dose of the proton beam. METHODS: SC-SP was composed of a flexible thin film solar cell and scintillating powder. The LET and dose of the pristine Bragg peak in the 14 cm range were calculated using a validated Monte Carlo model of a double scattering proton beam nozzle. The SC-SP was evaluated by measuring the proton beam under the same conditions at specific depths using SC-SP and Markus chamber. Finally, the 10 and 20 cm range pristine Bragg peaks and 5 cm spread-out Bragg peak (SOBP) in the 14 cm range were measured using the SC-SP and the Markus chamber. LETs measured using the SC-SP were compared with those calculated using Monte Carlo simulations. RESULTS: The quenching factors of the SC-SP and solar cell alone, which were slopes of linear fit obtained from quenching correction factors according to LET, were 0.027 and 0.070 µm/keV (R2 : 0.974 and 0.975). For pristine Bragg peaks in the 10 and 20 cm ranges, the maximum differences between LETs measured using the SC-SP and calculated using Monte Carlo simulations were 0.5 keV/µm (15.7%) and 1.2 keV/µm (12.0%), respectively. For a 5 cm SOBP proton beam, the LET measured using the SC-SP and calculated using Monte Carlo simulations differed by up to 1.9 keV/µm (18.7%). CONCLUSIONS: Comparisons of LETs for pristine Bragg peaks and SOBP between measured using the SC-SP and calculated using Monte Carlo simulations indicated that the solar cell-based system could simultaneously measure both LET and dose in real-time and is cost-effective.


Subject(s)
Proton Therapy , Protons , Powders , Linear Energy Transfer , Monte Carlo Method
6.
Med Phys ; 50(1): 557-569, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35993665

ABSTRACT

PURPOSE: A real-time solar cell based in vivo dosimetry system (SC-IVD) was developed using a flexible thin film solar cell and scintillating powder. The present study evaluated the clinical feasibility of the SC-IVD in electron beam therapy. METHODS: A thin film solar cell was coated with 100 mg of scintillating powder using an optical adhesive to enhance the sensitivity of the SC-IVD. Calibration factors were obtained by dividing the dose, measured at a reference depth for 6-20 MeV electron beam energy, by the signal obtained using the SC-IVD. Dosimetric characteristics of SC-IVDs containing variable quantities of scintillating powder (0-500 mg) were evaluated, including energy, dose rate, and beam angle dependencies, as well as dose linearity. To determine the extent to which the SC-IVD affected the dose to the medium, doses at R90 were compared depending on whether the SC-IVD was on the surface. Finally, the accuracy of surface doses measured using the SC-IVD was evaluated by comparison with surface doses measured using a Markus chamber. RESULTS: Charge measured using the SC-IVD increased linearly with dose and was within 1% of the average signal according to the dose rate. The signal generated by the SC-IVD increased as the beam angle increased. The presence of the SC-IVD on the surface of a phantom resulted in a 0.5%-2.2% reduction in dose at R90 for 6-20 MeV electron beams compared with the bare phantom. Surface doses measured using the SC-IVD system and Markus chamber differed by less than 5%. CONCLUSIONS: The dosimetric characteristics of the SC-IVD were evaluated in this study. The results showed that it accurately measured the surface dose without a significant difference of dose in the medium when compared with the Markus chamber. The flexibility of the SC-IVD allows it to be attached to a patient's skin, enabling real-time and cost-effective measurement.


Subject(s)
Electrons , In Vivo Dosimetry , Humans , Powders , Radiometry/methods , Film Dosimetry/methods
7.
Cancers (Basel) ; 14(23)2022 Nov 29.
Article in English | MEDLINE | ID: mdl-36497374

ABSTRACT

This research addresses the problem of interobserver variability (IOV), in which different oncologists manually delineate varying primary gross tumor volume (pGTV) contours, adding risk to targeted radiation treatments. Thus, a method of IOV reduction is urgently needed. Hypothesizing that the radiation oncologist's IOV may shrink with the aid of IOV maps, we propose IOV prediction network (IOV-Net), a deep-learning model that uses the fuzzy membership function to produce high-quality maps based on computed tomography (CT) images. To test the prediction accuracy, a ground-truth pGTV IOV map was created using the manual contour delineations of radiation therapy structures provided by five expert oncologists. Then, we tasked IOV-Net with producing a map of its own. The mean squared error (prediction vs. ground truth) and its standard deviation were 0.0038 and 0.0005, respectively. To test the clinical feasibility of our method, CT images were divided into two groups, and oncologists from our institution created manual contours with and without IOV map guidance. The Dice similarity coefficient and Jaccard index increased by ~6 and 7%, respectively, and the Hausdorff distance decreased by 2.5 mm, indicating a statistically significant IOV reduction (p < 0.05). Hence, IOV-net and its resultant IOV maps have the potential to improve radiation therapy efficacy worldwide.

8.
Sensors (Basel) ; 22(15)2022 Aug 04.
Article in English | MEDLINE | ID: mdl-35957376

ABSTRACT

Several detectors have been developed to measure radiation doses during radiotherapy. However, most detectors are not flexible. Consequently, the airgaps between the patient surface and detector could reduce the measurement accuracy. Thus, this study proposes a dose measurement system based on a flexible copper indium gallium selenide (CIGS) solar cell. Our system comprises a customized CIGS solar cell (with a size 10 × 10 cm2 and thickness 0.33 mm), voltage amplifier, data acquisition module, and laptop with in-house software. In the study, the dosimetric characteristics, such as dose linearity, dose rate independence, energy independence, and field size output, of the dose measurement system in therapeutic X-ray radiation were quantified. For dose linearity, the slope of the linear fitted curve and the R-square value were 1.00 and 0.9999, respectively. The differences in the measured signals according to changes in the dose rates and photon energies were <2% and <3%, respectively. The field size output measured using our system exhibited a substantial increase as the field size increased, contrary to that measured using the ion chamber/film. Our findings demonstrate that our system has good dosimetric characteristics as a flexible in vivo dosimeter. Furthermore, the size and shape of the solar cell can be easily customized, which is an advantage over other flexible dosimeters based on an a-Si solar cell.


Subject(s)
Copper , Indium , Gallium , Humans , Radiation Dosage , Radiometry , Selenium , X-Rays
9.
Cancers (Basel) ; 14(12)2022 Jun 11.
Article in English | MEDLINE | ID: mdl-35740553

ABSTRACT

The feasibility of proton minibeam radiation therapy (pMBRT) using a multislit collimator (MSC) and a scattering device was evaluated for clinical use at a clinical proton therapy facility. We fabricated, through Monte Carlo (MC) simulations, not only an MSC with a high peak-to-valley dose ratio (PVDR) at the entrance of the proton beam, to prevent radiation toxicity, but also a scattering device to modulate the PVDR in depth. The slit width and center-to-center distance of the diverging MSC were 2.5 mm and 5.0 mm at the large end, respectively, and its thickness and available field size were 100 mm and 76 × 77.5 mm2, respectively. Spatially fractionated dose distributions were measured at various depths using radiochromic EBT3 films and also tested on bacterial cells. MC simulation showed that the thicker the MSC, the higher the PVDR at the phantom surface. Dosimetric evaluations showed that lateral dose profiles varied according to the scatterer's thickness, and the depths satisfying PVDR = 1.1 moved toward the surface as their thickness increased. The response of the bacterial cells to the proton minibeams' depth was also established, in a manner similar to the dosimetric pattern. Conclusively, these results strongly suggest that pMBRT can be implemented in clinical centers by using MSC and scatterers.

10.
Med Phys ; 49(7): 4768-4779, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35396722

ABSTRACT

PURPOSE: To evaluate the dosimetric characteristics and applications of a dosimetry system composed of a flexible amorphous silicon thin-film solar cell and scintillator screen (STFSC-SS) for therapeutic X-rays. METHODS: The real-time dosimetry system was composed of a flexible a-Si thin-film solar cell (0.2-mm thick), a scintillator screen to increase its efficiency, and an electrometer to measure the generated charge. The dosimetric characteristics of the developed system were evaluated including its energy dependence, dose linearity, and angular dependence. Calibration factors for the signal measured by the system and absorbed dose-to-water were obtained by setting reference conditions. The application and correction accuracy of the developed system were evaluated by comparing the absorbed dose-to-water measured using a patient treatment beam with that measured using the ion chamber. RESULTS: The responses of STFSC-SS to energy, field size, depth, and source-to-surface distance (SSD) were more dependent on measurement conditions than were the responses of the ion chamber, although the former dependence was due to the scintillator screen, not the solar cell. The signals of STFSC-SS were also dependent on dose rate, while the responses of solar cell alone and scintillator screen were not dependent on dose rate. The scintillator screen reduced the output of solar cell at 6 and 15 MV by 0.60 and 0.55%, respectively. The different absorbed dose-to-water measured using STFSC-SS for patient treatment beam differed by 0.4% compared to those measured using the ionization chamber. The uncertainties of the developed system for 6 and 15 MV photon beams were 1.8 and 1.7%, respectively, confirming the accuracy and applicability of this system. CONCLUSIONS: The thin-film solar cell-based detector developed in this study can accurately measure absorbed dose-to-water. The increased signal resulting from the use of the scintillator screen is advantageous for measuring low doses and stable signal output. In addition, this system is flexible, making it applicable to curved surfaces, such as a patient's body, and is cost-effective.


Subject(s)
Radiometry , Silicon , Humans , Radiography , Radiometry/methods , Water , X-Rays
11.
Jpn J Clin Oncol ; 52(3): 266-273, 2022 Mar 03.
Article in English | MEDLINE | ID: mdl-34958091

ABSTRACT

OBJECTIVE: To propose and evaluate an active method for sparing the small bowel in the treatment field of cervical cancer brachytherapy by prone position procedure. METHODS: The prone position procedure consists of five steps: making bladder empty, prone-positioning a patient on belly board, making the small bowel move to abdomen, filling the bladder with Foley catheter and finally turning the patient into the supine position. The proposed method was applied for the treatment of seven cervical cancer patients. Its effectiveness was evaluated and a correlation between the patient characteristics and the volumetric dose reduction of small bowel was also investigated. Brachytherapy treatment plans were built before and after the proposed method, and their dose-volume histograms were compared for targets and organs-at-risk. In this comparison, all plans were normalized to satisfy the same D90% for high-risk clinical target volume. RESULTS: For the enrolled patients, the average dose of small bowel was significantly reduced from 75.2 ± 4.9 Gy before to 60.2 ± 4.0 Gy after the prone position procedure, while minor dosimetric changes were observed in rectum, sigmoid and bladder. The linear correlation to body mass index, thickness and width of abdominopelvic cavity and bladder volume were 76.2, 69.7, 28.8 and -36.3%, respectively. CONCLUSIONS: The application of prone position procedure could effectively lower the volumetric dose of the small bowel. The dose reduction in the small bowel had a strong correlation with the patient's obesity and abdominal thickness. This means the patients for whom the proposed method would be beneficial can be judiciously selected for safe brachytherapy.


Subject(s)
Brachytherapy , Uterine Cervical Neoplasms , Abdomen , Brachytherapy/methods , Female , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Rectum , Uterine Cervical Neoplasms/radiotherapy
12.
Front Oncol ; 11: 707464, 2021.
Article in English | MEDLINE | ID: mdl-34595112

ABSTRACT

To automatically identify optimal beam angles for proton therapy configured with the double-scattering delivery technique, a beam angle optimization method based on a convolutional neural network (BAODS-Net) is proposed. Fifty liver plans were used for training in BAODS-Net. To generate a sequence of input data, 25 rays on the eye view of the beam were determined per angle. Each ray collects nine features, including the normalized Hounsfield unit and the position information of eight structures per 2° of gantry angle. The outputs are a set of beam angle ranking scores (S beam) ranging from 0° to 359°, with a step size of 1°. Based on these input and output designs, BAODS-Net consists of eight convolution layers and four fully connected layers. To evaluate the plan qualities of deep-learning, equi-spaced, and clinical plans, we compared the performances of three types of loss functions and performed K-fold cross-validation (K = 5). For statistical analysis, the volumes V27Gy and V30Gy as well as the mean, minimum, and maximum doses were calculated for organs-at-risk by using a paired-samples t-test. As a result, smooth-L1 loss showed the best optimization performance. At the end of the training procedure, the mean squared errors between the reference and predicted S beam were 0.031, 0.011, and 0.004 for L1, L2, and smooth-L1 loss, respectively. In terms of the plan quality, statistically, PlanBAO has no significant difference from PlanClinic (P >.05). In our test, a deep-learning based beam angle optimization method for proton double-scattering treatments was developed and verified. Using Eclipse API and BAODS-Net, a plan with clinically acceptable quality was created within 5 min.

13.
Radiat Oncol ; 16(1): 154, 2021 Aug 17.
Article in English | MEDLINE | ID: mdl-34404441

ABSTRACT

BACKGROUND: Patient-specific dose prediction improves the efficiency and quality of radiation treatment planning and reduces the time required to find the optimal plan. In this study, a patient-specific dose prediction model was developed for a left-sided breast clinical case using deep learning, and its performance was compared with that of conventional knowledge-based planning using RapidPlan™. METHODS: Patient-specific dose prediction was performed using a contour image of the planning target volume (PTV) and organs at risk (OARs) with a U-net-based modified dose prediction neural network. A database of 50 volumetric modulated arc therapy (VMAT) plans for left-sided breast cancer patients was utilized to produce training and validation datasets. The dose prediction deep neural network (DpNet) feature weights of the previously learned convolution layers were applied to the test on a cohort of 10 test sets. With the same patient data set, dose prediction was performed for the 10 test sets after training in RapidPlan. The 3D dose distribution, absolute dose difference error, dose-volume histogram, 2D gamma index, and iso-dose dice similarity coefficient were used for quantitative evaluation of the dose prediction. RESULTS: The mean absolute error (MAE) and one standard deviation (SD) between the clinical and deep learning dose prediction models were 0.02 ± 0.04%, 0.01 ± 0.83%, 0.16 ± 0.82%, 0.52 ± 0.97, - 0.88 ± 1.83%, - 1.16 ± 2.58%, and - 0.97 ± 1.73% for D95%, Dmean in the PTV, and the OARs of the body, left breast, heart, left lung, and right lung, respectively, and those measured between the clinical and RapidPlan dose prediction models were 0.02 ± 0.14%, 0.87 ± 0.63%, - 0.29 ± 0.98%, 1.30 ± 0.86%, - 0.32 ± 1.10%, 0.12 ± 2.13%, and - 1.74 ± 1.79, respectively. CONCLUSIONS: In this study, a deep learning method for dose prediction was developed and was demonstrated to accurately predict patient-specific doses for left-sided breast cancer. Using the deep learning framework, the efficiency and accuracy of the dose prediction were compared to those of RapidPlan. The doses predicted by deep learning were superior to the results of the RapidPlan-generated VMAT plan.


Subject(s)
Breast Neoplasms/radiotherapy , Deep Learning , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Female , Humans , Middle Aged , Organs at Risk , Radiotherapy Dosage
14.
J Appl Clin Med Phys ; 22(6): 104-118, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34036701

ABSTRACT

The present study verified and evaluated the dosimetric effects of protons scattered from a snout and an aperture in clinical practice, when a range compensator was included. The dose distribution calculated by a treatment planning system (TPS) was compared with the measured dose distribution and the dose distribution calculated by Monte Carlo simulation at several depths. The difference between the measured and calculated results was analyzed using Monte Carlo simulation with filtration of scattering in the snout and aperture. The dependence of the effects of scattered protons on snout size, beam range, and minimum thickness of the range compensator was also investigated using the Monte Carlo simulation. The simulated and measured results showed that the additional dose compared with the results calculated by the TPS at shallow depths was mainly due to protons scattered by the snout and aperture. This additional dose was filtered by the structure of the range compensator so that it was observed under the thin region of the range compensator. The maximum difference was measured at a depth of 16 mm (8.25%), with the difference decreasing with depth. Analysis of protons contributing to the additional dose showed that the contribution of protons scattered from the snout was greater than that of protons scattered from the aperture when a narrow snout was used. In the Monte Carlo simulation, this effect of scattered protons was reduced when wider snouts and longer-range proton beams were used. This effect was also reduced when thicker range compensator bases were used, even with a narrow snout. This study verified the effect of scattered protons even when a range compensator was included and emphasized the importance of snout-scattered protons when a narrow snout is used for small fields. It indicated that this additional dose can be reduced by wider snouts, longer range proton beams, and thicker range compensator bases. These results provide a better understanding of the additional dose from scattered protons in clinical practice.


Subject(s)
Proton Therapy , Computer Simulation , Humans , Monte Carlo Method , Protons , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
15.
J Appl Clin Med Phys ; 22(2): 69-76, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33433064

ABSTRACT

PURPOSE: In passive scattering proton beam therapy, scattered protons from the snout and aperture increase the superficial dose, however, treatment planning systems (TPSs) based on analytic algorithms (such as proton convolution superposition) are often inaccurate in this aspect. This additional dose can cause permanent alopecia or severe radiation dermatitis. This study aimed to evaluate the effect of bolus on the superficial radiation dose in passive scattering proton beam therapy. METHODS: We drew a clinical target volume (CTV) and a scalp-p (phantom), and created plans using a TPS for a solid water phantom with and without bolus. We calculated the dose distribution in the established plans independently with Monte Carlo (MC) simulation and measured the actual dose distribution with an array of ion chambers and radiochromic films. To assess the clinical impact of bolus on scalp dose, we conducted independent dose verification using MC simulation in a clinical case. RESULTS: In the solid water phantom without bolus, the calculated scalp-p volume receiving 190 cGy was 20% with TPS but 80% with MC simulation when the CTV received 200 cGy. With 2 cm bolus, this decreased from 80% to 10% in MC simulation. With the measurements, average superficial dose to the scalp-p was reduced by 5.2% when 2 cm bolus was applied. In the clinical case, the scalp-c (clinical) volume receiving 3000 cGy decreased from 74% to 63% when 2 cm bolus was applied. CONCLUSION: This study revealed that bolus can reduce radiation dose at the superficial body area and alleviate toxicity in passive scattering proton beam therapy.


Subject(s)
Proton Therapy , Algorithms , Humans , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Scattering, Radiation
16.
J Appl Clin Med Phys ; 21(8): 191-199, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32515552

ABSTRACT

PURPOSE: Imaging, breath-holding/gating, and fixation devices have been developed to minimize setup errors so that the prescribed dose can be exactly delivered to the target volume in radiotherapy. Despite these efforts, additional patient monitoring devices have been installed in the treatment room to view patients' whole-body movement. We developed a facial expression recognition system using deep learning with a convolutional neural network (CNN) to predict patients' advanced movement, enhancing the stability of the radiation treatment by giving warning signs to radiation therapists. MATERIALS AND METHODS: Convolutional neural network model and extended Cohn-Kanade datasets with 447 facial expressions of source images for training were used. Additionally, a user interface that can be used in the treatment control room was developed to monitor real-time patient's facial expression in the treatment room, and the entire system was constructed by installing a camera in the treatment room. To predict the possibility of patients' sudden movement, we categorized facial expressions into two groups: (a) uncomfortable expressions and (b) comfortable expressions. We assumed that the warning sign about the sudden movement was given when the uncomfortable expression was recognized. RESULTS: We have constructed the facial expression monitoring system, and the training and test accuracy were 100% and 85.6%, respectively. In 10 patients, their emotions were recognized based on their comfortable and uncomfortable expressions with 100% detection rate. The detected various emotions were represented by a heatmap and motion prediction accuracy was analyzed for each patient. CONCLUSION: We developed a system that monitors the patient's facial expressions and predicts patient's advanced movement during the treatment. It was confirmed that our patient monitoring system can be complementarily used with the existing monitoring system. This system will help in maintaining the initial setup and improving the accuracy of radiotherapy for the patients using deep learning in radiotherapy.


Subject(s)
Deep Learning , Facial Expression , Humans , Monitoring, Physiologic , Movement , Neural Networks, Computer
17.
Radiat Oncol ; 14(1): 213, 2019 Nov 27.
Article in English | MEDLINE | ID: mdl-31775825

ABSTRACT

BACKGROUND: Accurate and standardized descriptions of organs at risk (OARs) are essential in radiation therapy for treatment planning and evaluation. Traditionally, physicians have contoured patient images manually, which, is time-consuming and subject to inter-observer variability. This study aims to a) investigate whether customized, deep-learning-based auto-segmentation could overcome the limitations of manual contouring and b) compare its performance against a typical, atlas-based auto-segmentation method organ structures in liver cancer. METHODS: On-contrast computer tomography image sets of 70 liver cancer patients were used, and four OARs (heart, liver, kidney, and stomach) were manually delineated by three experienced physicians as reference structures. Atlas and deep learning auto-segmentations were respectively performed with MIM Maestro 6.5 (MIM Software Inc., Cleveland, OH) and, with a deep convolution neural network (DCNN). The Hausdorff distance (HD) and, dice similarity coefficient (DSC), volume overlap error (VOE), and relative volume difference (RVD) were used to quantitatively evaluate the four different methods in the case of the reference set of the four OAR structures. RESULTS: The atlas-based method yielded the following average DSC and standard deviation values (SD) for the heart, liver, right kidney, left kidney, and stomach: 0.92 ± 0.04 (DSC ± SD), 0.93 ± 0.02, 0.86 ± 0.07, 0.85 ± 0.11, and 0.60 ± 0.13 respectively. The deep-learning-based method yielded corresponding values for the OARs of 0.94 ± 0.01, 0.93 ± 0.01, 0.88 ± 0.03, 0.86 ± 0.03, and 0.73 ± 0.09. The segmentation results show that the deep learning framework is superior to the atlas-based framwork except in the case of the liver. Specifically, in the case of the stomach, the DSC, VOE, and RVD showed a maximum difference of 21.67, 25.11, 28.80% respectively. CONCLUSIONS: In this study, we demonstrated that a deep learning framework could be used more effectively and efficiently compared to atlas-based auto-segmentation for most OARs in human liver cancer. Extended use of the deep-learning-based framework is anticipated for auto-segmentations of other body sites.


Subject(s)
Deep Learning , Image Processing, Computer-Assisted/methods , Liver Neoplasms/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Aged , Female , Humans , Liver Neoplasms/radiotherapy , Male , Middle Aged , Neural Networks, Computer , Observer Variation , Organs at Risk , Radiotherapy , Reproducibility of Results , Republic of Korea , Tomography, X-Ray Computed
18.
Med Phys ; 45(11): 5277-5282, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30133716

ABSTRACT

PURPOSE: Fabricate an acrylic disk radiation sensor (ADRS) and characterize the photoluminescence signal generated from the optical device as basis for the development and evaluation of a new dosimetry system for pencil beam proton therapy. METHODS: Based on the characteristics of the proposed optical dosimetry sensor, we established the relation between the photoluminescence output and the applied dose using an ionization chamber. Then, we obtained the relative integral depth dose profiles using the photoluminescence signal generated by pencil beam irradiation at energies of 99.9 and 162.1 MeV, and compared the results with the curve measured using a Bragg peak ionization chamber. RESULTS: The relation between the photoluminescence output and applied dose was linear. In addition, the ADRS was dose independent for beam currents up to 6 Gy/min, and the calibration factor for energy was close to 1. Hence, the energy dependence on the optical device can be disregarded. The integral depth dose profiles obtained for the ADRS suitable agreed with the curve measured in the Bragg peak ionization chamber without requiring correction. CONCLUSIONS: These results suggest that the ADRS is suitable for dosimetry measurements in pencil beam scanning, and it will be employed as a low-cost and versatile dosimetry sensor in upcoming developments.


Subject(s)
Proton Therapy/instrumentation , Radiometry/instrumentation , Radiotherapy Dosage
19.
Acta Oncol ; 57(10): 1359-1366, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30004264

ABSTRACT

BACKGROUND: The aim of the present study was to verify the dosimetric accuracy of two-dimensional (2D) in vivo rectal dosimetry using an endorectal balloon (ERB) with unfoldable EBT3 films for high-dose-rate (HDR) brachytherapy for cervical cancer. The clinical applicability of the technique was discussed. MATERIAL AND METHODS: ERB inflation makes the EBT3 films unrolled, whereas its deflation makes them rolled. Patient-specific quality assurance (pQA) tests were performed in 20 patient plans using an Ir-192 remote afterloading system and a water-filled cervical phantom with the ERB. The dose distributions measured in ERBs were compared with those of the treatment plans. RESULTS: The absolute dose profiles measured by the ERBs were in good agreement with those of treatment plans. The global gamma passing rates were 96-100% and 91-100% over 20 pQAs under the criteria of 3%/3 mm and 3%/2 mm, respectively, with a 30% low-dose threshold. Dose-volume histograms of the rectal wall were obtained from the measured dose distributions and showed small volume differences less than 2% on average from the patients' plans over the entire dose interval. The positioning error of the applicator set was detectable with high sensitivity of 12% dose area variation per mm. Additionally, the clinical applicability of the ERB was evaluated in volunteers, and none of them felt any pain when the ERB was inserted or removed. CONCLUSIONS: The 2D in vivo rectal dosimetry using the ERB with EBT3 films was effective and might be clinically applicable for HDR brachytherapy for cervical and prostate cancers to monitor treatment accuracy and consistency as well as to predict rectal toxicity.


Subject(s)
Brachytherapy/methods , Rectum/radiation effects , Uterine Cervical Neoplasms/radiotherapy , Female , Humans , Phantoms, Imaging , Radiotherapy Dosage
20.
Sensors (Basel) ; 18(1)2018 Jan 15.
Article in English | MEDLINE | ID: mdl-29342941

ABSTRACT

This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam monitoring system based on FORS was verified by comparing 2D dose maps of square-shaped fields of various sizes, which were obtained using conventional dosimeters such as MatriXX and EBT3 film, with those measured using FORS. The resulting full-width at half maximum and penumbra were compared for PBS proton beams, with a ≤2% difference between each value, indicating that measurements using the conventional dosimetric tool corresponded to measurements based on FORS. For irregularly-shaped fields, a comparison based on the gamma index between 2D dose maps obtained using MatriXX and EBT3 film and the 2D dose map measured by the FORS showed passing rates of 96.9 ± 1.3% and 96.2 ± 1.9%, respectively, confirming that FORS-based measurements for PBS proton therapy agreed well with those measured using the conventional dosimetric tools. These results demonstrate that the developed beam monitoring system based on FORS is good candidate for monitoring the entrance dose map in PBS proton therapy.

SELECTION OF CITATIONS
SEARCH DETAIL
...