Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters











Publication year range
1.
J Nanosci Nanotechnol ; 20(7): 4182-4187, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-31968438

ABSTRACT

The tunnel field-effect transistor (TFET) with surrounding channel nanowire (SCNW) structure promises better performance than the conventional planar TFET in terms of subthreshold swing (SS) and on-current (ION). In spite of the advantages of SCNW TFET, there are some technical issues in the aspects of a hump phenomenon in subthreshold region and a high ambipolar current (IAMB) in off-state. In order to overcome these issues, a novel dual-gate SCNW TFET (DG-SCNW TFET) with differential gate work functions (WFs) and a gate-drain underlap is proposed and studied by using technology computer-aided design (TCAD) simulation. In addition, a hetero-junction with SiGe source is applied to improve the device performance. Finally, it is confirmed that the optimized DG-SCNW TFET shows the remarkable performance comparing with the control device.

2.
J Audiol Otol ; 23(2): 76-82, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30989997

ABSTRACT

BACKGROUND AND OBJECTIVES: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. MATERIALS AND METHODS: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. RESULTS: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. CONCLUSIONS: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

3.
ACS Appl Mater Interfaces ; 10(31): 26405-26412, 2018 Aug 08.
Article in English | MEDLINE | ID: mdl-29998730

ABSTRACT

A new concept of a tunneling oxide-free nonvolatile memory device with a deep trap interface floating gate is proposed. This device demonstrates a high on/off current ratio of 107 and a sizable memory window due to deep traps at the interface between the channel and gate dielectric layers. Interestingly, irradiation with 400 nm light can completely restore the program state to the initial one (performing an erasing process), which is attributed to the visible light-sensitive channel layer. Device reproducibility is enhanced by selectively passivating shallow traps at the interface using in situ H2 plasma treatment. The passivated memory device shows highly reproducible memory operation and on-state current during retention bake tests at 85 °C. One of the most significant advantages of this visible light-erasable oxide field-effect transistor-based nonvolatile memory is its simple structure, which is free from deterioration due to the frequent tunneling processes, as compared to conventional nonvolatile memory devices with tunneling oxides.

4.
Nanotechnology ; 28(3): 035402, 2017 Jan 20.
Article in English | MEDLINE | ID: mdl-27934781

ABSTRACT

We investigated the ultraviolet (UV) responses of a heterojunction Si quantum dot (QD) solar cell consisting of p-type Si-QDs fabricated on a n-type crystalline Si (p-Si-QD/n-c-Si HJSC). The UV responses were compared with a conventional n-type crystalline Si solar cell (n-c-Si SC). The external and internal quantum efficiency results of the p-Si-QD/n-c-Si HJSC exhibited a clear enhancement in the UV responses (300-400 nm), which was not observed in the n-c-Si SC. Based on the results of the cell reflectance and bias-dependent responses, we expect that almost all UV responses occur in the p-Si-QD layer, and the generated carriers can be transported via the Si-QD layer due to the formation of a sufficient electric filed. As a result, a high power conversion efficiency of 14.5% was achieved from the p-Si-QD/n-c-Si HJSC. By reducing the thickness of the n-Si substrate from 650 µm to 300 µm, more enhanced power conversion efficiency of 14.8% was obtained which is the highest value among the reported Si-QD based solar cells to date.

5.
Sci Rep ; 6: 32300, 2016 08 26.
Article in English | MEDLINE | ID: mdl-27562634

ABSTRACT

Artificially designed acoustic meta-surfaces have the ability to manipulate sound energy to an extraordinary extent. Here, we report on a new type of directional reflective surface consisting of an array of sub-wavelength Helmholtz resonators with varying internal coiled path lengths, which induce a reflection phase gradient along a planar acoustic meta-surface. The acoustically reshaped reflective surface created by the gradient-impeding meta-surface yields a distinct focal line similar to a parabolic cylinder antenna, and is used for directive sound beamforming. Focused beam steering can be also obtained by repositioning the source (or receiver) off axis, i.e., displaced from the focal line. Besides flat reflective surfaces, complex surfaces such as convex or conformal shapes may be used for sound beamforming, thus facilitating easy application in sound reinforcement systems. Therefore, directional reflective surfaces have promising applications in fields such as acoustic imaging, sonic weaponry, and underwater communication.


Subject(s)
Acoustics/instrumentation , Sound Localization , Sound Spectrography/instrumentation , Sound , Acoustic Stimulation , Algorithms , Humans , Models, Theoretical , Signal Processing, Computer-Assisted , Sound Spectrography/methods
6.
J Acoust Soc Am ; 139(5): 2324, 2016 05.
Article in English | MEDLINE | ID: mdl-27250128

ABSTRACT

In this paper, the sound transmission loss (STL) of thin double plates with an air cavity between them in a rigid duct is considered using an analytical approach. The vibration motion of the plate and sound pressure field are expanded in terms of an infinite series of the modal functions. Under the plane wave condition, a low frequency solution is derived by including the first few symmetric modes. It is determined that the peak frequencies of the double plates coincide with those of each single plate. When the two plates are identical, the STL becomes zero at the natural frequencies of the single plate. However, when the two plates are not identical, the STL is always greater than zero. The location and amplitude of the dips are investigated using an approximate solution when the cavity depth is very small. It is observed that dividing the single plate into two plates with an air cavity in between degrades the STL in the low frequency range, while the equivalent surface mass density is preserved. However, when the cavity depth is not small, the STL of the single plate can be smaller than that of the double plates.

7.
J Bone Metab ; 22(4): 183-9, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26713309

ABSTRACT

BACKGROUND: Bisphosphonates (BPs) are the most commonly used anti-osteoporotic drugs, which have been proven to reduce the risk of osteoporotic fractures. However, use of BPs, particularly for long periods of time, is associated with an increased risk of atypical femoral fracture (AFF). Healing of BP-associated AFF is usually delayed because of suppressed bone turnover. Teriparatide (TPTD), a recombinant form of parathyroid hormone (PTH), enhances bone healing in patients with delayed healing or non-union. METHODS: In this study, we summarized and performed a systemic review of the published literature on treatment of AFF using TPTD. RESULTS: Although there is a lack of level 1 studies on the evidence of TPTD in promoting bone union in AFFs, this systemic review of the available literature revealed that TPTD works positively in AFFs, and we put together the evidence that TPTD is a viable treatment option for enhancing fracture healing in AFFs. CONCLUSIONS: While anecdotal evidence of beneficial effects of TPTD on fracture healing offer limited guidance for clinical decision making, a better understanding of the role of TPTD in fracture healing may be elucidated with future prospective trials.

8.
Korean J Urol ; 55(11): 732-6, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25405015

ABSTRACT

PURPOSE: Transrectal ultrasound (TRUS)-guided biopsy of the prostate is usually safe. However, some patients are hospitalized owing to complications from TRUS biopsy. We identified the risk factors for complications and effective preventive measures for treating complications after TRUS biopsy. MATERIALS AND METHODS: Medical records and radiological images of 1,083 patients who underwent TRUS biopsy of the prostate over 10 years in Gyeongsang National University Hospital were examined retrospectively to investigate the correlation between complications after TRUS biopsy and preventive antibiotics, prebiopsy enema, number of biopsy cores, and pathological findings. RESULTS: Complications occurred in 69 patients (6.4%). The complication rates of the 1,008 patients who received antibiotics and the 75 patients who did not were 6.3% and 8.0%, respectively (p=0.469). Complication rates of the pre-biopsy enema group (n=658) and the group without prebiopsy enema (n=425) were 4.7% and 8.9%, respectively (p=0.007). Complication rates of the 6-core biopsy group (n=41) and the 12-core biopsy group (n=955) were 7.3% and 6.3%, respectively (p=0.891). Complication rates of the prostate cancer group (n=306) and the no prostate cancer group (n=713) were 6.2% and 6.6%, respectively (p=0.740). CONCLUSIONS: A prebiopsy enema was associated with a reduced risk of complications after TRUS biopsy. Preventive antibiotics, number of biopsy cores, and pathological findings did not significantly influence the complication rate.


Subject(s)
Endosonography , Enema/methods , Image-Guided Biopsy/adverse effects , Prostatic Neoplasms/pathology , Prostatitis/prevention & control , Syncope, Vasovagal/prevention & control , Urinary Retention/prevention & control , Aged , Humans , Image-Guided Biopsy/methods , Incidence , Male , Prostatitis/epidemiology , Prostatitis/etiology , Rectum , Republic of Korea/epidemiology , Retrospective Studies , Risk Factors , Syncope, Vasovagal/epidemiology , Syncope, Vasovagal/etiology , Urinary Retention/epidemiology , Urinary Retention/etiology
9.
Sci Rep ; 4: 4165, 2014 Mar 03.
Article in English | MEDLINE | ID: mdl-24584552

ABSTRACT

The emission enhancement of sound without electronic components has wide applications in a variety of remote systems, especially when highly miniaturized (smaller than wavelength) structures can be used. The recent advent of acoustic metamaterials has made it possible to realize this. In this study, we propose, design, and demonstrate a new class of acoustic cavity using a double-walled metamaterial structure operating at an extremely low frequency. Periodic zigzag elements which exhibit Fabry-Perot resonant behavior below the phononic band-gap are used to yield strong sound localization within the subwavelength gap, thus providing highly effective emission enhancement. We show, both theoretically and experimentally, 10 dB sound emission enhancement near 1060 Hz that corresponds to a wavelength approximately 30 times that of the periodicity. We also provide a general guideline for the independent tuning of the quality factor and effective volume of acoustic metamaterials. This approach shows the flexibility of our design in the efficient control of the enhancement rate.

10.
J Nanosci Nanotechnol ; 14(11): 8309-14, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25958519

ABSTRACT

A scattering matrix (S-matrix) analysis method was developed for evaluating hydrogenated amorphous silicon (a-Si:H)-based thin film solar cells. In this approach, light wave vectors A and B represent the incoming and outgoing behaviors of the incident solar light, respectively, in terms of coherent wave and incoherent intensity components. The S-matrix determines the relation between A and B according to optical effects such as reflection and transmission, as described by the Fresnel equations, scattering at the boundary surfaces, or scattering within the propagation medium, as described by the Beer-Lambert law and the change in the phase of the propagating light wave. This matrix can be used to evaluate the behavior of angle-incident coherent and incoherent light simultaneously, and takes into account not only the light scattering process at material boundaries (haze effects) but also nonlinear optical processes within the material. The optical parameters in the S-matrix were determined by modeling both a 2%-gallium-doped zinc oxide transparent conducting oxide and germanium-compounded a-Si:H (a-SiGe:H). Using the S-matrix equations, the photocurrent for an a-Si:H/a-SiGe:H tandem cell and the optical loss in semitransparent a-Si:H solar cells for use in building-integrated photovoltaic applications were analyzed. The developed S-matrix method can also be used as a general analysis tool for various thin film solar cells.

11.
J Ethnopharmacol ; 149(2): 597-9, 2013 Sep 16.
Article in English | MEDLINE | ID: mdl-23872254

ABSTRACT

ETHNOPHARMACOLOGICAL RELEVENCE: The ginseng root has been traditionally used as a sedative in oriental countries. However, the condition "ginseng abuse syndrome" (GAS), defined as hypertension, nervousness, sleeplessness, skin eruption, and morning diarrhea, was coined as a result of a study of people who had been using a variety of ginseng preparations. However, we reported that administration of RGE increased rapid eye movement (REM) and non rapid eye movement (NREM) sleep via GABAergic systems in animals. Therefore, this study was performed to investigate how red ginseng extract (RGE) affects sleeping behaviors in human volunteers. MATERIALS AND METHODS: RGE (1500 mg) was orally administered to young male healthy volunteers (from 15 to 37 years old ages, n=15) three times a day for 7 days. Overnight polysomnographic (PSG) studies were performed two times, 1 day before and 7 days after RGE administration. We investigated differences in sleep architecture parameters such as total sleep time (TST), sleep efficacy (SE: total sleep time/time in bed), proportion of each sleep stage, and wakefulness after sleep onset (WASO) between baseline PSG and PSG after RGE administration. RESULTS: Total wake time (TWT) was significantly reduced (P<0.05) and SE was increased (P<0.05), although slow wave sleep stage 1 (N1) was reduced (P<0.01) and non-rapid eye movement (REM) sleep was increased (P<0.03) after administration. CONCLUSION: From these results, it is presumed that RGE intake would improve the quality of sleep, thus having beneficial effects on sleep disturbed subjects.


Subject(s)
Panax , Plant Extracts/pharmacology , Sleep/drug effects , Adolescent , Adult , Healthy Volunteers , Humans , Male , Polysomnography , Young Adult
12.
J Acoust Soc Am ; 114(1): 98-113, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12880024

ABSTRACT

Although there are many analytical and empirical models for orifice impedance, the predicted acoustical performance when adopting any one of them sometimes shows a large discrepancy with the measured result in some cases. In order to obtain a new practical and precise empirical impedance model under grazing flow conditions, the acoustic impedance of circular orifices has been measured with a variation of the involved parameters under very carefully tested and controlled measurement conditions. The parameters involved in determining the acoustic impedance of an orifice are comprised of the orifice diameter, orifice thickness, perforation ratio, mean flow velocity, and frequency. The range of involved parameters is chosen to cover the practical data span of perforates in typical exhaust systems of internal combustion engines. The empirical impedance model is obtained by using nonlinear regression analysis of the various results of the parametric tests. The proposed empirical model of orifice impedance, with a very high correlation coefficient, is applied to the prediction of the transmission loss of concentric resonators, which have geometric configurations typical of acoustically short and long through-flow resonators. By comparing the measured and predicted results, in which the predictions are made by employing many previous orifice impedance models as well as the present model, it is confirmed that the proposed orifice impedance model yields the most accurate prediction among all other existing impedance models.

13.
J Acoust Soc Am ; 114(6 Pt 1): 3076-86, 2003 Dec.
Article in English | MEDLINE | ID: mdl-14714789

ABSTRACT

It is well known that the presence of a grazing mean flow affects the acoustic impedance of an aperture, but the detailed nature and understanding of the influence is still unknown. In this paper, results from a recent theoretical analysis of the problem are compared with a new set of experimental results. The purpose is twofold. First, the experimental results are used to validate the theory. It is found that the theory predicts the resistance quite well, but not the reactance. Second, the theory is used to try and give some physical understanding to the experimental results. In particular, some scaling laws are confirmed, and it is also shown that measured negative resistance values are to be expected. They are not erroneous, as previously thought. Former sets of experimental data for this problem are notable for the amount of variation that they display. Thus, both the theory and the new experimental results are also compared with those earlier detailed results that most closely conform to the conditions assumed here, namely fully developed turbulent pipe flow of low Mach number past circular orifices. The main field of application is in flow ducts, in particular, flow through perforated tubes in exhaust mufflers.

SELECTION OF CITATIONS
SEARCH DETAIL