Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
Add more filters










Publication year range
1.
Acta Crystallogr A ; 56 (Pt 2): 119-26, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10772453

ABSTRACT

A method to invert the dynamical diffraction of high-energy electrons inside a crystal, which takes into account absorption, is discussed. It is shown that, working at fixed energy, the projected potentials associated with both the elastic and the absorptive scattering can be uniquely obtained from the scattering matrix. Inversion is possible for any principal orientation of the incident beam. Model examples are given.

2.
J Microsc ; 195(Pt 1): 23-33, 1999 Jul.
Article in English | MEDLINE | ID: mdl-10444299

ABSTRACT

A method for accurate dimensional and angular measurements of microstructures analysed in the scanning electron microscope is described. The method considers central and parallel projections and involves (a) digital image acquisition of stereopaired images from the scanning electron microscope's photodisplay, (b) generation of 3D-image representations, (c) setting of measuring points in the digitized stereopaired images, (d) computation of exact space coordinates (x/y/z) from the corresponding point coordinates (xL/yL; xR/yR), (e) determination of distances and angles between consecutive corresponding points using vector equations, and (f) transfer of computed data into spreadsheets of the data analysis software using dynamic data exchange with simultaneous graphical display of the frequency distribution of variables. Measurements performed on specimens with known dimensions (grid with 10 microm wide square meshes, polystyrene beads with 0.33 microm diameter) and angles (synthetic crystals of K(Al,Cr)[SO4], CuSO4.5H2O and NaCl) revealed a high accuracy in dimensional as well as angular measurements (total error 1 +/- 0.5%). In Monte Carlo experiments the overall error was found to depend strongly on the size of the measured structure relative to the size of the measurement field (field width).


Subject(s)
Image Processing, Computer-Assisted , Microscopy, Electron, Scanning
3.
Acta Crystallogr A ; 55(Pt 2 Pt 1): 105-111, 1999 Mar 01.
Article in English | MEDLINE | ID: mdl-10927239

ABSTRACT

The retrieval of a unique crystal potential from the scattering matrix S in high-energy transmission electron diffraction is discussed. It is shown that, in general, data taken at a single orientation are not sufficient to determine all the elements of S. Additional measurements with tilted incident beam are required for the determination of the whole S matrix. An algorithm for the extraction of the crystal potential from the S matrix measured at a single energy and thickness is presented. The limiting case of thin crystals is discussed. Several examples with simulated data are considered.

5.
Phys Rev A ; 48(5): 3504-3512, 1993 Nov.
Article in English | MEDLINE | ID: mdl-9910014
7.
Phys Rev C Nucl Phys ; 45(6): 2919-2925, 1992 Jun.
Article in English | MEDLINE | ID: mdl-9968058
8.
Phys Rev Lett ; 68(10): 1472-1475, 1992 Mar 09.
Article in English | MEDLINE | ID: mdl-10045140
10.
Phys Rev C Nucl Phys ; 32(4): 1223-1230, 1985 Oct.
Article in English | MEDLINE | ID: mdl-9952963
11.
Phys Rev C Nucl Phys ; 32(3): 789-795, 1985 Sep.
Article in English | MEDLINE | ID: mdl-9952906
12.
Phys Rev D Part Fields ; 31(8): 2029-2034, 1985 Apr 15.
Article in English | MEDLINE | ID: mdl-9955932
SELECTION OF CITATIONS
SEARCH DETAIL
...