Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Med ; 91(6): 2374-2390, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38225861

ABSTRACT

PURPOSE: To evaluate the performance of various MR electrical properties tomography (MR-EPT) methods at 3 T in terms of absolute quantification and spatial resolution limit for electrical conductivity. METHODS: Absolute quantification as well as spatial resolution performance were evaluated on homogeneous phantoms and a phantom with holes of different sizes, respectively. Ground-truth conductivities were measured with an open-ended coaxial probe connected to a vector network analyzer (VNA). Four widely used MR-EPT reconstruction methods were investigated: phase-based Helmholtz (PB), phase-based convection-reaction (PB-cr), image-based (IB), and generalized-image-based (GIB). These methods were compared using the same complex images from a 1 mm-isotropic UTE sequence. Alternative transceive phase acquisition sequences were also compared in PB and PB-cr. RESULTS: In large homogeneous phantoms, all methods showed a strong correlation with ground truth conductivities (r > 0.99); however, GIB was the best in terms of accuracy, spatial uniformity, and robustness to boundary artifacts. In the resolution phantom, the normalized root-mean-squared error of all methods grew rapidly (>0.40) when the hole size was below 10 mm, with simplified methods (PB and IB), or below 5 mm, with generalized methods (PB-cr and GIB). CONCLUSION: VNA measurements are essential to assess the accuracy of MR-EPT. In this study, all tested MR-EPT methods correlated strongly with the VNA measurements. The UTE sequence is recommended for MR-EPT, with the GIB method providing good accuracy for structures down to 5 mm. Structures below 5 mm may still be detected in the conductivity maps, but with significantly lower accuracy.


Subject(s)
Brain , Image Processing, Computer-Assisted , Image Processing, Computer-Assisted/methods , Algorithms , Magnetic Resonance Imaging/methods , Electric Conductivity , Phantoms, Imaging , Tomography/methods
2.
Article in English | MEDLINE | ID: mdl-38083553

ABSTRACT

Magnetic Resonance electrical property tomography (MR-EPT) is a non-invasive imaging modality that reconstructs the living biological tissue's conductivity σ and εr permittivity using spatial derivatives of the measured RF field, also termed B1 data, in a magnetic resonance imaging system. The spatial derivative operator, particularly the Laplacian, amplifies the noise in the reconstructed electrical property (EP) maps, hence decreasing accuracy and increasing boundary artifacts. We propose a novel adaptative convolution kernel for generating numerical derivatives based on 3D Savitzky-Golay (SG) filters and local segmentation in a magnitude image. In comparison to typical SG kernel, the proposed kernel allows arbitrary shapes and sizes to vary with local tissue. It provides an automatic trade-off between noise and resolution, thereby significantly enhancing reconstruction accuracy and eliminating boundary artifacts.


Subject(s)
Magnetic Resonance Imaging , Tomography , Phantoms, Imaging , Magnetic Resonance Imaging/methods , Tomography/methods , Magnetic Resonance Spectroscopy , Electric Conductivity
3.
ACS Appl Mater Interfaces ; 11(32): 28631-28640, 2019 Aug 14.
Article in English | MEDLINE | ID: mdl-31334634

ABSTRACT

The development of advanced techniques of fabrication of three-dimensional (3D) microenvironments for the study of cell growth and proliferation has become one of the major motivations of material scientists and bioengineers in the past decade. Here, we present a novel residueless 3D structuration technique of poly(dimethylsiloxane) (PDMS) by water-in-PDMS emulsion casting and subsequent curing process in temperature-/pressure-controlled environment. Scanning electron microscopy and X-ray microcomputed tomography allowed us to investigate the impact of those parameters on the microarchitecture of the porous structure. We demonstrated that the optimized emulsion casting process gives rise to large-scale and highly interconnected network with pore size ranging from 500 µm to 1.5 mm that turned out to be nicely adapted to 3D cell culture. Experimental cell culture validations were performed using SaOS-2 (osteosarcoma) cell lines. Epifluorescence and deep penetration imaging techniques as two-photon confocal microscopy unveiled information about cell morphology and confirmed a homogeneous cell proliferation and spatial distribution in the 3D porous structure within an available volume larger than 1 cm3. These results open alternative scenarios for the fabrication and integration of porous scaffolds for the development of 3D cell culture platforms.


Subject(s)
Cellular Microenvironment , Materials Testing , Silicones/chemistry , Cell Line, Tumor , Emulsions , Humans , Porosity , Tissue Scaffolds , Water
4.
J Magn Reson ; 294: 153-161, 2018 09.
Article in English | MEDLINE | ID: mdl-30053754

ABSTRACT

This article presents a new motion encoding strategy to perform magnetic resonance elastography (MRE). Instead of using standard motion encoding gradients, a tailored RF pulse is designed to simultaneously perform selective excitation and motion encoding in presence of a constant gradient. The RF pulse is designed with a numerical optimal control algorithm, in order to obtain a magnetization phase distribution that depends on the displacement characteristics inside each voxel. As a consequence, no post-excitation encoding gradients are required. This offers numerous advantages, such as reducing eddy current artifacts, and relaxing the constraint on the gradients maximum switch rate. It also allows to perform MRE with ultra-short TE acquisition schemes, which limits T2 decay and optimizes signal-to-noise ratio. The pulse design strategy is developed and analytically analyzed to clarify the encoding mechanism. Finally, simulations, phantom and ex vivo experiments show that phase-to-noise ratios are improved when compared to standard MRE encoding strategies.

5.
J Magn Reson ; 281: 82-93, 2017 08.
Article in English | MEDLINE | ID: mdl-28558274

ABSTRACT

This paper investigates the use of Optimal Control (OC) theory to design Radio-Frequency (RF) pulses that actively control the spatial distribution of the MRI magnetization phase. The RF pulses are generated through the application of the Pontryagin Maximum Principle and optimized so that the resulting transverse magnetization reproduces various non-trivial and spatial phase patterns. Two different phase patterns are defined and the resulting optimal pulses are tested both numerically with the ODIN MRI simulator and experimentally with an agar gel phantom on a 4.7T small-animal MR scanner. Phase images obtained in simulations and experiments are both consistent with the defined phase patterns. A practical application of phase control with OC-designed pulses is also presented, with the generation of RF pulses adapted for a Magnetic Resonance Elastography experiment. This study demonstrates the possibility to use OC-designed RF pulses to encode information in the magnetization phase and could have applications in MRI sequences using phase images.

SELECTION OF CITATIONS
SEARCH DETAIL
...