1.
J Chromatogr Sci ; 39(10): 425-30, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11669367

ABSTRACT

A high-performance liquid chromatographic method with amperometric detection has been developed for the determination of the diuretic bumetanide using a microBondapak C18 column. The mobile phase consists of a 50:50 acetonitrile-water mixture containing 5mM KH2PO4-K2HPO4 (pH 4.0). The compound is monitored at +1350 mV with an amperometric detector equipped with a glassy carbon working electrode. A liquid-liquid or solid-liquid extraction is done prior to chromatographic analysis in order to avoid the interferences found in the urine matrix. The percentages of recovery obtained are 71%+/-1% for liquid-liquid extraction and 84.2%+/-0.7% for solid-liquid extraction. The method developed has a linear concentration range from 50 to 499 ng/mL with a reproducibility in terms of relative standard deviation of 1.73% and 3.85% for a concentration level of 70 ng/mL and 237 ng/mL, respectively, and a detection limit of 0.25 ng/mL (3:1 signal-to-noise ratio). The method is applied to the determination of bumetanide in pharmaceutical formulations and urine obtained from hypertensive patients and healthy volunteers after the ingestion of a therapeutic dose of Fordiuran (1 mg bumetanide).


Subject(s)
Bumetanide/analysis , Chromatography, High Pressure Liquid/methods , Diuretics/analysis , Adult , Bumetanide/urine , Diuretics/urine , Electrochemistry , Female , Humans , Male , Reproducibility of Results
2.
J Chromatogr Sci ; 37(8): 283-7, 1999 Aug.
Article in English | MEDLINE | ID: mdl-10457602

ABSTRACT

A high-performance liquid chromatographic method with amperometric detection for the determination of the diuretic indapamide using a muBondapak C18 column is developed. The mobile phase consists of an acetonitrile-water mixture (45:55, 5 mM) in KH2PO4-K2HPO4 (pH 4.0). The compound is monitored at +1200 mV with an amperometric detector equipped with a glassy carbon working electrode. A liquid-liquid or solid-liquid extraction is performed prior to chromatographic analysis to avoid the interferences found in urine matrix. Percentages of recovery are 88.3 +/- 5.6 and 82.9 +/- 7.8 for liquid-liquid and solid-liquid extraction, respectively. The developed method has a linear concentration range from 25 to 315 ng/mL with a reproducibility in terms of relative standard deviation of 4% for a concentration level of 0.5 microgram/mL and a quantitation limit of 1 ng/mL. The method is applied to the determination of indapamide in tablets and urine obtained from hypertensive patients after the ingestion of Tertensif (indapamide 2.5 mg).


Subject(s)
Chromatography, High Pressure Liquid/methods , Diuretics/analysis , Indapamide/analysis , Indapamide/urine , Pharmaceutical Preparations/analysis , Adult , Diuretics/urine , Female , Humans , Hydrogen-Ion Concentration , Hypertension/urine , Male , Middle Aged