J Virol Methods ; 244: 39-45, 2017 06.
Article in English | MEDLINE | ID: mdl-28274744

ABSTRACT

Although access to antiretroviral therapy for HIV infection is increasing in resource-poor countries, viral load testing for monitoring of treatment efficacy remains limited, expensive, and confined to centralized laboratories. The SAMBA HIV-1 Semi-Q Test is a nucleic acid-based amplification assay developed for viral load monitoring performed on either the semi-automated SAMBA I system for laboratory use or the fully automated SAMBA II system for point-of care use. We have assessed the performance characteristics of the SAMBA HIV-1 Semi-Q Test on SAMBA I and SAMBA II systems according to the Common Technical Specifications of the European Community's 98/79 In Vitro Diagnostic Medical Devices Directive. The sensitivity, specificity, reproducibility, and viral subtype coverage of the test were similar on the SAMBA I and SAMBA II platforms. The clinical performance on the SAMBA I system was compared with the Roche CAP/CTM assay and evaluated in-house with 130 patient specimens from London as well as in the field with 390 specimens in Kenya and Zimbabwe. The overall concordance between the SAMBA and CAP/CTM assays was 98.1%. The clinical performance of the test on the SAMBA II platform in comparison with the Abbott HIV-1 RealTime Assay was evaluated in-house with 150 specimens from Ukraine, yielding a concordance of 98.0%. The results thus show that the SAMBA HIV-1 Semi-Q Test performs equivalently on SAMBA I and SAMBA II, and they suggest that the test is suitable for implementation at the point-of-care in resource-poor regions where viral load testing is desperately needed but often unavailable.


Subject(s)
HIV Infections/virology , HIV-1/isolation & purification , Point-of-Care Systems , Viral Load/methods , Automation, Laboratory/methods , Humans , Kenya , London , Reproducibility of Results , Sensitivity and Specificity , Ukraine , Zimbabwe
2.
J Virol Methods ; 237: 143-149, 2016 11.
Article in English | MEDLINE | ID: mdl-27568275

ABSTRACT

The SAMBA HIV-1 Qual Whole Blood Test is a nucleic acid-based amplification assay for the qualitative detection of HIV-1 in whole blood of adults or infants. The test can be run on either the semi-automated SAMBA I system for clinical use or the fully automated, including readout, SAMBA II system for point-of-care use in resource-limited settings. We have assessed the performance characteristics of the SAMBA HIV-1 Qual Whole Blood Test on SAMBA I and SAMBA II. The limit of detection obtained for the two tests were 518IU/ml and 399copies/ml on SAMBA I and 457IU/ml and 433copies/ml on SAMBA II. Test specificity on both systems was 100% with a panel of 503 HIV-1 negative samples. Evaluation of test reproducibility showed 100% concordance with expected gold standard results as well as 100% agreement between operators, days, and runs as well as within runs on both SAMBA I and SAMBA II. Our results thus show that the SAMBA HIV-1 Qual Whole Blood Test performs equivalently on SAMBA I and SAMBA II, and also suggest that the test is suitable for implementation in medium-throughput clinical facilities (SAMBA I) or low-throughput point-of-care (POC) settings (SAMBA II) in resource-poor regions.


Subject(s)
HIV Infections/diagnosis , HIV-1/genetics , Nucleic Acid Amplification Techniques , Point-of-Care Systems , Adult , Early Diagnosis , HIV Infections/virology , Humans , Infant , Limit of Detection , Nucleic Acid Amplification Techniques/methods , Nucleic Acid Amplification Techniques/standards , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity , Viremia/diagnosis , Viremia/virology