Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
Add more filters










Publication year range
1.
Nat Commun ; 15(1): 161, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38167498

ABSTRACT

Accurate parameters of molecular hot-band transitions, i.e., those starting from vibrationally excited levels, are needed to accurately model high-temperature spectra in astrophysics and combustion, yet laboratory spectra measured at high temperatures are often unresolved and difficult to assign. Optical-optical double-resonance (OODR) spectroscopy allows the measurement and assignment of individual hot-band transitions from selectively pumped energy levels without the need to heat the sample. However, previous demonstrations lacked either sufficient resolution, spectral coverage, absorption sensitivity, or frequency accuracy. Here we demonstrate OODR spectroscopy using a cavity-enhanced frequency comb probe that combines all these advantages. We detect and assign sub-Doppler transitions in the spectral range of the 3ν3 ← ν3 resonance of methane with frequency precision and sensitivity more than an order of magnitude better than before. This technique will provide high-accuracy data about excited states of a wide range of molecules that is urgently needed for theoretical modeling of high-temperature data and cannot be obtained using other methods.

2.
J Chem Phys ; 159(18)2023 Nov 14.
Article in English | MEDLINE | ID: mdl-37937939

ABSTRACT

Double Resonance is a powerful spectroscopic method that unambiguously assigns the rigorous quantum numbers of one state of a transition. However, there is often ambiguity as to the branch (ΔJ) of that transition. Spectroscopists have resolved this ambiguity by using the dependence of the double resonance intensity on the relative polarization directions of pump and probe radiation. However, published theoretical predictions for this ratio are based upon a weak (i.e., non-saturating) field approximation. This paper presents theoretical predictions for these intensity ratios for cases where the pump field is strongly saturating in the two limits of transitions dominated by homogeneous or of inhomogeneous broadening. Saturation reduces but does not eliminate the magnitude of the polarization effect (driving the intensity ratio closer to unity) even with strong pump saturation. For the case of an inhomogeneously broadened line, such as when Doppler broadened linewidth dominates over the power-broadened homogeneous line width, a large fraction of the low pump power polarization anisotropy remains. This paper reports predicted polarization ratios for both linear and circular pump and probe field polarizations. The present predictions are compared with experimental measurements on CH4 ground state → ν3 → 3ν3 transitions recently reported by de Oliveira et al.63 and these are in better agreement than with the weak field predictions.

3.
J Chem Phys ; 154(10): 104105, 2021 Mar 14.
Article in English | MEDLINE | ID: mdl-33722054

ABSTRACT

A weak excitation transit-time resolution limited analytic line shape is derived for a Doppler broadening-free degenerate two-photon transition from a standing wave with a TEM00 transverse profile. This approximation is appropriate when the collisional mean free path is much larger than the transverse width of the TEM00 beam. It is considerably simpler than the two-photon absorption line shape previously published, Bordé, C. R. Hebd. Seances Acad. Sci., Ser. B 282, 341-344 (1976), which was derived for more general experimental conditions. The case of a saturating field, with an intensity-dependent shift of the resonance frequency, is treated and expressed in reduced units. Numerical calculations are presented for the line shape for a range of the reduced intensity and light intensity shifts values.

4.
Phys Rev Lett ; 126(6): 063001, 2021 Feb 12.
Article in English | MEDLINE | ID: mdl-33635699

ABSTRACT

We report the first measurement of sub-Doppler molecular response using a frequency comb by employing the comb as a probe in optical-optical double-resonance spectroscopy. We use a 3.3 µm continuous wave pump and a 1.67 µm comb probe to detect sub-Doppler transitions to the 2ν_{3} and 3ν_{3} bands of methane with ∼1.7 MHz center frequency accuracy. These measurements provide the first verification of the accuracy of theoretical predictions from highly vibrationally excited states, needed to model the high-temperature spectra of exoplanets. Transition frequencies to the 3ν_{3} band show good agreement with the TheoReTS line list.

5.
Article in English | MEDLINE | ID: mdl-33103022

ABSTRACT

We report Doppler-free two-photon absorption of N2O at λ = 4.53 µm, measured by cavity ring-down spectroscopy. High power was achieved by optical self-locking of a quantum cascade laser to a linear resonator of finesse F = 22730 , and accurate laser detuning over a 400 MHz range was measured relative to an optical frequency comb. At a sample pressure of p = 0.13 kPa, we report a large two-photon cross-section per molecule of σ 13 ( 2 ) = 8.0 × 10 - 41 cm4 s for the Q(18) rovibrational transition at a resonant frequency of ν 0 = 66179400.8 MHz.

7.
J Chem Phys ; 151(14): 144201, 2019 Oct 14.
Article in English | MEDLINE | ID: mdl-31615233

ABSTRACT

This paper presents an analysis of near-resonant, rovibrational two-photon spectroscopy and the use of cavity ring-down spectroscopy for its detection. Expressions are derived for the photon absorption rate of a three-level system, correct to all orders and the simpler expressions that result from various approximations. The analysis includes the angular momentum projection degeneracies and linear or circular polarization of the exciting field. Expressions are derived for the rate of two-photon power loss for light inside a resonant cavity. Explicit calculations are made for excitation of the ν3 mode of 12C16O2 for which the two-photon excitation spectrum is dominated by a single v3 = 0 → 2, Q(16) line at ν̃=2335.826 cm-1. This transition has an intermediate v3 = 0 → 1, P(16) one-photon transition that is off resonance by 0.093 cm-1 (2.8 GHz). At 1 Torr total pressure, the Q(16) two-photon transition is calculated to have a cross section of 2.99 × 10-38 cm4 s per CO2 molecule in the J = 16 state or 2.24 × 10-39 cm4 s per CO2 molecule at 300 K. The analysis of the sensitivity limits for 2-photon cavity ring-down spectroscopy predicts a theoretical detection limit of 32 ppq (10-15) Hz-1/2 for 12C16O2, higher sensitivity than has been realized using one-photon absorption. The analysis predicts that most polyatomic molecules will have sparse, Doppler-free two-photon absorption spectra, which will dramatically increase the selectivity of trace gas detection of samples with multiple components with overlapping absorption bands. This is demonstrated by the predicted mid-IR two-photon absorption spectrum of butadiene using theoretical spectroscopic constants.

8.
J Chem Phys ; 149(9): 094201, 2018 Sep 07.
Article in English | MEDLINE | ID: mdl-30195302

ABSTRACT

Pulse flip angles are calculated for three-wave mixing, three-state cycles of chiral molecules to produce optimized free induction decay amplitudes proportional to the enantiomeric excess of a sample and to produce optimized degrees of state-specific enantiomeric separation. The calculations account for the spatial degeneracy of the levels involved and the resulting inhomogeneous distribution of transition dipole moments. Cycles of transitions that include R followed by Q followed by P branch transitions display only modest reductions of the calculated optimal signals compared to those calculated if every M component was optimally polarized. Transition cycles P-Q-R are only slightly worse, while the Q-Q-Q cycles are much worse, increasingly so, as the rotational total quantum number is increased.

9.
J Chem Phys ; 146(13): 134305, 2017 Apr 07.
Article in English | MEDLINE | ID: mdl-28390374

ABSTRACT

We report the first experimental gas-phase observation of an asymmetric, trans-N2O4 formed by the dimerization of NO2. In additional to the dominant 14N216O4 species, rotational transitions have been observed for all species with single 15N and 18O substitutions as well as several multiply substituted isotopologues. These transitions were used to determine a complete substitution structure as well as an r0 structure from the fitted zero-point averaged rotational constants. The determined structure is found to be that of an ON-O-NO2 linkage with the shared oxygen atom closer to the NO2 than the NO (1.42 vs 1.61 Å). The structure is found to be nearly planar with a trans O-N-O-N linkage. From the spectra of the 14N15NO4 species, we were able to determine the nuclear quadrupole coupling constants for each specific nitrogen atom. The equilibrium structure determined by ab initio quantum chemistry calculations is in excellent agreement with the experimentally determined structure. No spectral evidence of the predicted asymmetric, cis-N2O4 was found in the spectra.

10.
Astrobiology ; 16(10): 787-797, 2016 10.
Article in English | MEDLINE | ID: mdl-27732068

ABSTRACT

In this study, near-infrared continuous wave cavity ring-down spectroscopy was applied to the measurement of the δ2H of methane (CH4). The cavity ring-down spectrometer (CRDS) system consisted of multiple DFB laser diodes to optimize selection of spectral line pairs. By rapidly switching measurements between spectral line peaks and the baseline regions, the long-term instrumental drift was minimized, substantially increasing measurement precision. The CRDS system coupled with a cryogenic pre-concentrator measured the δ2H of terrestrial atmospheric CH4 from 3 standard liters of air with a precision of ±1.7‰. The rapidity with which both C and H isotopic measurements of CH4 can be made with the CRDS will enable hourly monitoring of diurnal variations in terrestrial atmospheric CH4 signatures that can be used to increase the resolution of global climate models for the CH4 cycle. Although the current instrument is not capable of measuring the δ2H of 10 ppbv of martian CH4, current technology does exist that could make this feasible for future spaceflight missions. As biological and abiotic CH4 sources have overlapping carbon isotope signatures, dual-element (C and H) analysis is key to reliable differentiation of these sources. Such an instrument package would therefore offer improved ability to determine whether or not the CH4 recently detected in the martian atmosphere is biogenic in origin. Key Words: Arctic-Hydrogen isotopes-Atmospheric CH4-CRDS-Laser. Astrobiology 16, 787-797.


Subject(s)
Atmosphere/chemistry , Carbon Isotopes/chemistry , Hydrogen/analysis , Methane/chemistry , Spectroscopy, Near-Infrared/instrumentation , Arctic Regions , Feasibility Studies , Freezing , Lasers , Spectroscopy, Near-Infrared/methods
11.
Proc Natl Acad Sci U S A ; 112(40): 12315-20, 2015 Oct 06.
Article in English | MEDLINE | ID: mdl-26392538

ABSTRACT

Raman spectroscopy is an important tool in understanding chemical components of various materials. However, the excessive weight and energy consumption of a conventional CCD-based Raman spectrometer forbids its applications under extreme conditions, including unmanned aircraft vehicles (UAVs) and Mars/Moon rovers. In this article, we present a highly sensitive, shot-noise-limited, and ruggedized Raman signal acquisition using a time-correlated photon-counting system. Compared with conventional Raman spectrometers, over 95% weight, 65% energy consumption, and 70% cost could be removed through this design. This technique allows space- and UAV-based Raman spectrometers to robustly perform hyperspectral Raman acquisitions without excessive energy consumption.


Subject(s)
Photons , Spectrum Analysis, Raman/instrumentation , Spectrum Analysis, Raman/methods , Aircraft , Algorithms , Equipment Design , Exobiology/instrumentation , Exobiology/methods , Mars , Moon , Remote Sensing Technology/instrumentation , Reproducibility of Results , Spacecraft
12.
J Phys Chem Lett ; 6(1): 196-200, 2015 Jan 02.
Article in English | MEDLINE | ID: mdl-26263113

ABSTRACT

We describe a three-wave mixing experiment using time-separated microwave pulses to detect the enantiomer-specific emission signal of the chiral molecule using Fourier transform microwave (FTMW) spectroscopy. A chirped-pulse FTMW spectrometer operating in the 2-8 GHz frequency range is used to determine the heavy-atom substitution structure of solketal (2,2-dimethyl-1,3-dioxolan-4-yl-methanol) through analysis of the singly substituted (13)C and (18)O isotopologue rotational spectra in natural abundance. A second set of microwave horn antennas is added to the instrument design to permit three-wave mixing experiments where an enantiomer-specific phase of the signal is observed. Using samples of R-, S-, and racemic solketal, the properties of the three-wave mixing experiment are presented, including the measurement of the corresponding nutation curves to demonstrate the optimal pulse sequence.

13.
Anal Chem ; 87(6): 3345-53, 2015 Mar 17.
Article in English | MEDLINE | ID: mdl-25692741

ABSTRACT

S-Nitroso compounds have received much attention in biological research. In addition to their role as nitric oxide donors, there is growing evidence that these compounds are involved in signaling processes in biological systems. Determination of S-nitrosylated proteins is of great importance for fundamental biological research and medical applications. The most common method to assay biological S-nitroso compounds is to chemically or photochemically reduce SNO functional groups to release nitric oxide, which is then entrained in an inert gas stream and detected, usually through chemiluminescence. We report a method of S-nitroso compound detection using cavity ring-down measurements of gaseous NO absorbance at 5.2 µm. The proposed method, in contrast to the chemiluminescence-based approach, can be used to distinguish isotopic forms of NO. We demonstrated sensitivity down to ∼2 pmol of S(14)NO groups and ∼5 pmol of S(15)NO groups for S-nitroso compounds in aqueous solutions. The wide dynamic range of cavity ring-down detection allows the measurement of S-nitroso compound levels from pico- to nanomole amounts.


Subject(s)
Nitric Oxide/analysis , Spectrophotometry, Infrared/methods , Limit of Detection , Nitric Oxide/chemistry , Photochemical Processes , S-Nitrosothiols/analysis , S-Nitrosothiols/chemistry
14.
Anal Chem ; 85(23): 11250-7, 2013 Dec 03.
Article in English | MEDLINE | ID: mdl-24160448

ABSTRACT

A near-infrared (NIR) continuous-wave-cavity ring-down spectrometry (CW-CRDS) device was developed with the goal of measuring seasonal changes in the isotopic composition of atmospheric CH4 on Earth and eventually on Mars. The system consisted of three distributed feedback laser diodes (DFB-LDs), two of which were tuned to the absorption line peaks of (12)CH4 and (13)CH4 at 6046.954 cm(-1) and 6049.121 cm(-1), respectively, and a third that measured the baseline at 6050.766 cm(-1). The multiple laser design improved the long-term stability of the system and increased the data acquisition rate. The acquisition frequency was further increased by utilizing a semiconductor optical amplifier (SOA) to initiate cavity ring-down events. The high repetition rate combined with the superhigh reflectivity mirrors yielded precise isotopic measurements in this NIR region, even though the line strengths of CH4 in this region are 200 times weaker than those of the strongest mid-IR absorption bands. The current system has a detection limit of 1.9 × 10(-12) cm(-1), corresponding to 10 pptv of CH4 at 100 Torr. For ambient air samples that contained 1.9 ppmv CH4, the δ(13)C of the CH4 was determined to be -48.7 ± 1.7‰ (1σ).

15.
J Phys Chem A ; 117(50): 13399-411, 2013 Dec 19.
Article in English | MEDLINE | ID: mdl-23978273

ABSTRACT

An optimized nonlinear least-squares fit algorithm for data processing in cavity ring-down spectroscopy (CRDS) is discussed, which improves the calculation efficiency substantially over using a general purpose fitting package. Theoretical absorption sensitivity limits for both the detector noise and the shot noise limited situations are derived and compared with experimental results. The effect of limiting the bandwidth of detection system on ring-down signal is discussed and compared with real ring-down data. The optimal trigger level and fitting interval are obtained for continuous wave cavity ring-down spectroscopy (cw-CRDS) in both the detector noise and shot noise limits, with the resulting sensitivity in units of cm(-1) per (Hz(1/2)) derived. Interestingly, it is found that the optimized shot noise limited sensitivity in cw-CRDS method is, in principle, comparable with the ultimate sensitivity of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS).

16.
Rev Sci Instrum ; 83(4): 043115, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22559523

ABSTRACT

A novel cell for continuous wave cavity ring-down spectroscopy (cw-CRDS) is described and tested. The cell is monolithic and maintains a rigid alignment of the two cavity mirrors. Two high-resolution and high-force piezoelectric transducers are used to sweep the length of the cell by elastic deformation of the 2.86 cm outer diameter stainless steel tube that makes up the body of the cell. The cavity length is scanned more than 1/2 wavelength of the near-IR light used, which ensures that at least one TEM(00) mode of the cavity will pass through resonance with the laser. This allows the use of a frequency-locked-laser cw-CRDS technique, which increases the precision of the measurements compared to the alternative of sweeping the laser more than one free spectral range of the cavity. The performance of the cell is demonstrated by using it to detect the absorption spectrum of methane (CH(4)) at the wavenumber regions of around 6051.8-6057.7 cm(-1).

17.
J Phys Chem A ; 115(34): 9411-21, 2011 Sep 01.
Article in English | MEDLINE | ID: mdl-21790164

ABSTRACT

The averaged transmitted intensity of a cavity excited by a linearly frequency swept laser with finite line width is derived and presented as a sum over passes, analytical integrals (where the sum of passes is converted to a continuous time variable), and an approximate but computationally more stable stationary phase approximation expression. The transmitted waveform is used to derive the bias in extraction of the cavity decay rate from such a cavity transient for three different fitting models. Numerical simulation of cavity excitation gives statistical fluctuations in the transmitted intensity that leads to noise in the cavity decay rate. For a range of parameters spanning those likely to be encountered in real experiments, numerical results are presented. These demonstrate that the theoretical signal-to-noise ratio and thus sensitivity of swept cavity (or equivalently, frequency) CRDS is substantially below that for CRDS where one attenuates the laser either with current modulation or with an external modulator.

18.
Appl Opt ; 49(8): 1378-87, 2010 Mar 10.
Article in English | MEDLINE | ID: mdl-20220895

ABSTRACT

Allan variance has been used to characterize the slow drift of a near-IR distributed feedback laser-based continuous wave cavity ringdown spectroscopy (CW-CRDS) system. Long-term drift in the cavity loss rate, highly correlated with changes in ambient pressure but not temperature, is observed. With differential measurement of on- and off-peak decay rates, the drift between them largely cancels out, but some residual drift remains if the lasers are detuned more than a few hundred megahertz from each other. A sensitivity to bulk cavity loss (1sigma) of 4.4 x 10(-12) cm(-1) has been obtained during an optimum integration time of approximately 30 min with our CW-CRDS setup, which corresponds to the methane detection limit (3sigma) in N(2) of 0.24 parts in 10(9) by volume (ppbv) at 20 Torr or 29 parts in 10(12) by volume (pptv) at 760 Torr pressure. The stability of our system is demonstrated by measuring sub-ppbv methane in N(2) at 760 Torr through recording the spectrum of methane lines with our setup.

19.
J Phys Chem A ; 114(10): 3391-402, 2010 Mar 18.
Article in English | MEDLINE | ID: mdl-20151690

ABSTRACT

Infrared (IR) laser spectroscopy is used to probe the rotational and vibrational dynamics of the (HCN)(m)-M(n) (M = K, Ca, Sr) complexes, either solvated within or bound to the surface of helium nanodroplets. The IR spectra of the (HCN)(m)-K (m = 1-3), HCN-Sr, and HCN-Ca complexes have the signature of a surface species, similar to the previously reported spectra of HCN-M (M = Na, K, Rb, Cs) [Douberly, G. E.; Miller, R. E. J. Phys. Chem. A 2007, 111, 7292.]. A second band in the HCN-Ca spectrum is assigned to a solvated complex. The relative intensities of the two HCN-Ca bands are droplet size dependent, with the solvated species being favored in larger droplets. IR-IR double resonance spectroscopy is used to probe the interconversion of the two distinct HCN-Ca populations. While only a surface-bound HCN-Sr species is initially produced, CH stretch vibrational excitation results in a population transfer to a solvated state. Complexes containing multiple HCN molecules and one Sr atom are surface-bound, while the nu(1) (HCN)(2)Ca spectrum has both the solvated and surface-bound signatures. All HCN-(Ca,Sr)(n) (n > or = 2) complexes are solvated following cluster formation in the droplet. Density-functional calculations of helium nanodroplets interacting with the HCN-M show surface binding for M = Na with a binding energy of 95 cm(-1). The calculations predict a fully solvated complex for M = Ca. For M = Sr, a 2.2 cm(-1) barrier is predicted between nearly isoenergetic surface binding and solvated states.

20.
Appl Opt ; 48(16): 2966-78, 2009 Jun 01.
Article in English | MEDLINE | ID: mdl-19488107

ABSTRACT

The design of a high finesse optical cavity made from two prism retroreflectors is fully described. Optical beam propagation calculations to determine the specification of prism angles and relative dimensions, the size of the astigmatic TEM00 beam as it propagates in the cavity, and the sensitivity of the optic axis to changes in prism alignment and fabrication errors are presented. The effects of material dispersion are also quantified for three different materials: fused silica, calcium fluoride, and barium fluoride. The predictions made are found to be in good agreement with experimental results obtained from prisms we had made from fused silica. Prisms made of CaF2 and BaF2 are predicted to be useful for applications in the UV and mid-IR spectral regions, respectively.

SELECTION OF CITATIONS
SEARCH DETAIL
...