1.
Article in English | MEDLINE | ID: mdl-38878017

ABSTRACT

BACKGROUND: Comparative efficacy and safety data on radiofrequency ablation (RFA) versus pulsed field ablation (PFA) for common idiopathic left ventricular arrhythmia (LV-VAs) locations are lacking. OBJECTIVES: This study sough to compare RFA with PFA of common idiopathic LV-VAs locations. METHODS: Ten swine were randomized to PFA or RFA of LV interventricular septum, papillary muscle, LV summit via distal coronary sinus, and LV epicardium via subxiphoid approach. Ablations were delivered using an investigational dual-energy (RFA/PFA) contact force (CF) and local impedance-sensing catheter. After 1-week survival, animals were euthanized for lesion assessment. RESULTS: A total of 55 PFA (4 applications/site of 2.0 KV, target CF ≥10 g) and 36 RFA (CF ≥10 g, 25-50 W targeting ≥50 Ω local impedance drop, 60-second duration) were performed. LV interventricular septum: average PFA depth 7.8 mm vs RFA 7.9 mm (P = 0.78) and no adverse events. Papillary muscle: average PFA depth 8.1 mm vs RFA 4.5 mm (P < 0.01). Left ventricular summit: average PFA depth 5.6 mm vs RFA 2.7 mm (P < 0.01). Steam-pop and/or ventricular fibrillation in 4 of 12 RFA vs 0 of 12 PFA (P < 0.01), no ST-segment changes observed. Epicardium: average PFA depth 6.4 mm vs RFA 3.3 mm (P < 0.01). Transient ST-segment elevations/depressions occurred in 4 of 5 swine in the PFA arm vs 0 of 5 in the RFA arm (P < 0.01). Angiography acutely and at 7 days showed normal coronaries in all cases. CONCLUSIONS: In this swine study, compared with RFA, PFA of common idiopathic LV-VAs locations produced deeper lesions with fewer steam pops. However, PFA was associated with higher rates of transient ST-segment elevations and depressions with direct epicardium ablation.

2.
Circ Arrhythm Electrophysiol ; 17(6): e012723, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38690671

ABSTRACT

BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P<0.01 for each. Histology confirmed transmural lesions with both modalities. Experiment II: With PF, lesion depth, width, and volume were larger with higher degrees of CF (depth: r=0.82, P<0.001; width: r=0.26, P=0.052; and volume: r=0.55, P<0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.


Subject(s)
Cardiac Catheters , Catheter Ablation , Equipment Design , Animals , Catheter Ablation/instrumentation , Catheter Ablation/methods , Swine , Heart Atria/physiopathology , Heart Atria/surgery , Models, Animal , Sus scrofa , Heart Ventricles/physiopathology , Heart Ventricles/surgery
3.
JACC Clin Electrophysiol ; 10(2): 222-234, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37978965

ABSTRACT

BACKGROUND: The efficacy of pulsed field ablation (PFA) for redo procedures is unknown. OBJECTIVES: In this study, the authors aimed to evaluate the effectiveness of PFA when performing PFA over chronic RFA (redo environment). METHODS: This was a 3-step in vivo study. In step 1 (creation of redo environment), 6 swine underwent radiofrequency ablation (RFA) with a local impedance measuring catheter and a contact force-enabled catheter in 3 different sites: the right atrium (RA) (intercaval line with intentional gaps), the left atrium (LA) (pulmonary vein isolation [PVI] with intentional gaps and superficial posterior wall ablations), and the left ventricle (LV) (short RFA applications [chronic RFA]). In step 2 (re-ablation), following a survival period of ≈5 weeks, animals were retreated as follows: in the RA, a focal PFA catheter over the prior intercaval line; in the LA, PVI using a pentaspline PFA catheter; and in the LV, animals were randomized to focal PFA or RFA. In each arm, 2 types of lesions were performed: acute or acute over chronic. In step 3 (remapping and euthanization), following an additional 3 to 5 days, all animals were remapped and sacrificed. RESULTS: In the RA, re-ablation with PFA resulted in a complete intercaval block in all animals, expanding and homogenizing the disparate chronic RFA lesions from a width of 4 to 7 mm (chronic RFA) to a width of 16 to 28 mm (PFA over chronic RFA). In the LA, re-ablation with PFA resulted in complete PVI and transmural ablation of the PW. In the LV, the mean depth for acute RFA (post 2-5 days survival) was 7.6 ± 1.3 mm vs 3.9 ± 1.6 mm in the acute over chronic RFA lesions (P < 0.01). In contrast, the mean depth for acute PFA was 7.0 ± 1.6 mm, similar to when ablating with PFA over RFA (7.1 ± 1.3 mm; P = 0.94). CONCLUSIONS: PFA is highly efficient for ablation following prior RFA, which may be beneficial in patients presenting for redo procedures. In the ventricle, PFA resulted in lesions that are deeper than RFA when ablating over chronic superficial RFA lesions.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Humans , Animals , Swine , Heart Atria/surgery , Heart Ventricles/surgery , Catheters , Electric Impedance
4.
Front Physiol ; 12: 808541, 2021.
Article in English | MEDLINE | ID: mdl-35082695

ABSTRACT

Background: The purpose of this study was to assess the effect local impedance (LI) has on an ablation workflow when combined with a contact force (CF) ablation catheter. Methods: Left pulmonary vein isolation was performed in an in vivo canine model (N = 8) using a nominal (30 W) or an elevated (50 W) power strategy with a CF catheter. The catheter was enabled to measure LI prior to and during ablation. LI was visible for only one of the vein isolations. Results: Chronic block was achieved in all animals when assessed 30 ± 5 days post-ablation procedure with a median LI drop during RF ranging from 23.0 to 34.0 Ω. In both power cohorts, the median radiofrequency (RF) duration decreased if LI was visible to the operator (30 W only CF: 17.0 s; 30 W CF + LI: 14.0 s, p = 0.009; 50 W only CF: 6.0 s; 50 W CF + LI: 4.0 s, p = 0.019). An inverse relationship between the LI prior to RF delivery and the RF duration required to achieve an effective lesion was observed. There was no correlation between the magnitude of the applied force and the drop in LI, once at least 5 g was achieved. Conclusions: An elevated power strategy with the context of CF and LI led to the most efficient titration of successful RF energy delivery. The combination of feedback allows for customization of the ablation strategy based on local tissue variation rather than a uniform approach that could potentially lead to overtreatment. Higher LI drops were more readily achievable when an elevated power strategy was utilized, especially in conditions where the catheter was coupled against tissue with low resistivity. Clinical study is warranted to determine if there is an additive safety benefit to visualizing the dynamics of the tissue response to RF energy with LI when an elevated power strategy is used.