Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Comput Methods Biomech Biomed Engin ; 22(12): 1020-1031, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31084272

ABSTRACT

Finite element analysis is a common tool that has been used for the past few decades to predict the mechanical behavior of bone. However, to our knowledge, there are no round-robin finite element analyses of long human bones with more than two participating biomechanics laboratories published yet, where the results of the experimental tests were not known in advance. We prepared a fresh-frozen human femur for a compression test in a universal testing machine measuring the strains at 10 bone locations as well as the deformation of the bone in terms of the displacement of the loading point at a load of 2 kN. The computed tomography data of the bone with a calibration phantom as well as the orientation of the bone in the testing machine with the according boundary conditions were delivered to seven participating laboratories. These were asked to perform a finite element analysis simulating the experimental setup and deliver their results to the coordinator without knowing the experimental results. Resultantly, four laboratories had deviations from the experimentally measured strains of less than 40%, and three laboratories had deviations of their numerically determined values compared to the experimental data of more than 120%. These deviations are thought to be based on different material laws and material data, as well as different material mapping methods. Investigations will be conducted to clarify and assess the reasons for the large deviations in the numerical data. It was shown that the precision of finite element models of the human femur is not yet as developed as desired by the biomechanics community.


Subject(s)
Femur/physiology , Finite Element Analysis , Laboratories , Biomechanical Phenomena , Humans , Models, Biological , Reproducibility of Results , Stress, Mechanical , Tomography, X-Ray Computed/methods
2.
J Neurotrauma ; 34(16): 2389-2395, 2017 08 15.
Article in English | MEDLINE | ID: mdl-28381107

ABSTRACT

Worldwide, more than 22 million children and adolescents are exposed to repetitive head impacts (RHI) in soccer. Evidence indicates cumulative effects on brain structure, but it is not known whether exposure to RHI affects cognitive improvement in adolescents. The aim of the study was to determine whether exposure to RHI while heading the ball in soccer affects improvement in cognitive performance in adolescents over time. The study group consisted of a convenience sample of 16 male soccer players (mean age 15.7 ± 0.7 years). A comparison cohort of 14 male non-contact sports athletes (mean age 14.9 ± 1.1 years) was recruited from competitive athletic clubs and group-matched in age. Using the ProPoint and AntiPoint tasks, sensorimotor and cognitive functions were measured over both immediate (pre- vs. post-training) as well as across multiple time points within a play season. The number and type of head impacts that occurred during the training were counted. The main outcome measure was the change in response time (RT) in the ProPoint and AntiPoint tasks. The immediate (pre- vs. post-training) and longer-term (across a play season) change in RT was analyzed, and the effect of the number and type of head impacts was tested. Thirty athletes with and without exposure to RHI demonstrated a decrease in RT in both tasks immediately after training. Over the play season, both groups showed improvement in sensorimotor function. While the control group also improved in cognitive performance, the soccer players did not, however. Further, the more long headers performed, the slower the improvement in RT over the season. Youth athletes experience an immediate cognitive improvement after training most likely because of physical exercise. Results of this study also suggest an association between exposure to specific RHI (long headers) and lack of improvement in cognitive performance in youth athletes over time.


Subject(s)
Brain Concussion/complications , Cognitive Dysfunction/etiology , Soccer/injuries , Adolescent , Athletes , Cognitive Dysfunction/epidemiology , Cohort Studies , Humans , Longitudinal Studies , Male , Prospective Studies , Reaction Time
3.
Materials (Basel) ; 6(10): 4675-4688, 2013 Oct 22.
Article in English | MEDLINE | ID: mdl-28788354

ABSTRACT

The transfer characteristic of the human middle ear with an applied middle ear implant (floating mass transducer) is examined computationally with a Multi-body System approach and compared with experimental results. For this purpose, the geometry of the middle ear was reconstructed from µ-computer tomography slice data and prepared for a Multi-body System simulation. The transfer function of the floating mass transducer, which is the ratio of the input voltage and the generated force, is derived based on a physical context. The numerical results obtained with the Multi-body System approach are compared with experimental results by Laser Doppler measurements of the stapes footplate velocities of five different specimens. Although slightly differing anatomical structures were used for the calculation and the measurement, a high correspondence with respect to the course of stapes footplate displacement along the frequency was found. Notably, a notch at frequencies just below 1 kHz occurred. Additionally, phase courses of stapes footplate displacements were determined computationally if possible and compared with experimental results. The examinations were undertaken to quantify stapes footplate displacements in the clinical practice of middle ear implants and, also, to develop fitting strategies on a physical basis for hearing impaired patients aided with middle ear implants.

4.
Sarcoma ; 2011: 545104, 2011.
Article in English | MEDLINE | ID: mdl-21559264

ABSTRACT

Reconstruction of the extensor mechanism is essential for good extremity function after endoprosthetic knee replacement following tumor resection. Only a few biological methods have been able to reliably restore a functional extensor mechanism, but they are often associated with significant complication rates. Reattachment of the patellar tendon to the prosthesis using an alloplastic patellar ligament (Trevira cord) can be an appropriate alternative. In vivo and in vitro studies have already shown that complete fibrous ingrowth in polyethylene chords can be seen after a period of six months. However, until now, no biomechanical study has shown the efficacy of an alloplastic cord and its fixation device in providing sufficient stability and endurance in daily life-activity until newly formed scar tissue can take over this function. In a special test bench developed for this study, different loading regimes were applied to simulate loads during everyday life. Failure loads and failure modes were evaluated. The properties of the cord were compared before and after physiological conditioning. It was shown that rubbing was the mode of failure under dynamic loading. Tensile forces up to 2558 N did not result in material failure. Thus, using an artificial cord together with this fixation device, temporary sufficient stable fixation can be expected.

SELECTION OF CITATIONS
SEARCH DETAIL
...