Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Forensic Sci ; 49(6): 1265-77, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15568700

ABSTRACT

Analysis of length polymorphism at short tandem repeat (STR) loci utilizing the polymerase chain reaction (PCR) process has proven to be an ideal assay for human identification purposes. The short length of STR loci coupled with the amplification of target sequence through PCR allows for a robust, sensitive, and specific assay for highly polymorphic markers. A multiplex containing fifteen STR loci plus the gender-determining locus Amelogenin was developed to provide a single amplification/detection of all CODIS (Combined DNA Index System) STR loci (CSF1PO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, and vWA) as well as two internationally-accepted STRs (D2S1338 and D19S433). By incorporating five-dye fragment analysis technology and non-nucleotide linkers, previously optimized AmpFlSTR kit primer sequences have been maintained. This kit has been developed in accordance with the standards of the forensic community as defined by the DNA Advisory Board. Validation studies were performed to include developmental validation, and the results support the use of the AmpFlSTR Identifiler PCR Amplification Kit for human identity and parentage testing.


Subject(s)
DNA Fingerprinting/methods , Polymerase Chain Reaction/methods , Tandem Repeat Sequences , Animals , Bacteria/genetics , Cats , Cattle , Chickens , DNA Primers , Deoxyribonucleotides , Dogs , Genotype , Horses , Humans , Indicators and Reagents , Magnesium Chloride , Mice , Polymorphism, Genetic , Potassium Chloride , Sequence Analysis, DNA , Species Specificity , Swine , Temperature , Yeasts/genetics
2.
Forensic Sci Int ; 133(3): 220-7, 2003 May 05.
Article in English | MEDLINE | ID: mdl-12787655

ABSTRACT

A population study of Chamorros and Filipinos using short tandem repeat (STR) loci amplified with the AmpFlSTR Profiler Plus PCR amplification kit demonstrated an excess of observed homozygosity at the D8S1179 locus. Use of a different set of D8S1179 primers to type the same samples did not demonstrate an excess of homozygosity and showed discordant genotypes at the D8S1179 locus. A single point mutation, G-to-A transition, 16 nucleotides from the 3' end of the reverse primer, was identified to cause allele dropout when using the AmpFlSTR Profiler Plus primer set. An additional D8S1179 reverse primer specific for the variant was constructed resulting in the recovery of the null allele. The primer was included in the newly developed AmpFlSTR Identifiler PCR amplification kit. No deleterious effects or non-specific peaks were observed in validation experiments evaluating primer concentration, Mg2+ concentration, annealing temperature and population samples.


Subject(s)
Alleles , DNA Primers , Point Mutation , Tandem Repeat Sequences , Binding Sites , DNA Fingerprinting/methods , Genetics, Population , Genotype , Homozygote , Humans , Magnesium Chloride , Polymerase Chain Reaction , Reproducibility of Results , Sequence Analysis, DNA
SELECTION OF CITATIONS
SEARCH DETAIL
...