Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Radiat Prot Dosimetry ; 180(1-4): 42-45, 2018 Aug 01.
Article in English | MEDLINE | ID: mdl-29518232

ABSTRACT

This study describes the use of a neutron irradiator system based on a plutonium-beryllium neutron source for MnSO4 solution activation for use to determine the MSB system efficiency. Computational simulations using Monte Carlo code were performed to establish the main characteristics of the irradiator system. Among the simulated geometries and volumes, semi-cylindrical shape with 84.5 cm3 of MnSO4 solution yielded the best option to be built. Activity measurements were performed with a high-pure germanium detector to validate the new irradiation system. Results showed an average efficiency and uncertainty of the experimental standard deviation of the mean: 5.742 × 10-4 ± 0.036 × 10-4 (coverage factor k = 1), for MSB system. Efficiency value obtained shows good correlation to other published methods (i.e. a relative difference of 0.07%). This alternative metrological method demonstrated the utility of neutron sources for the irradiation of solutions in metrology laboratories providing a cost-efficient alternative to nuclear reactors or particle accelerators.


Subject(s)
Beryllium/analysis , Manganese Compounds/chemistry , Neutrons , Plutonium/analysis , Radiation Monitoring/instrumentation , Sulfates/chemistry , Calibration , Monte Carlo Method , Radiation Dosage
2.
Radiat Prot Dosimetry ; 180(1-4): 29-32, 2018 Aug 01.
Article in English | MEDLINE | ID: mdl-29136235

ABSTRACT

The Laboratório de Ciências Radiológicas is developing an irradiator for neutron survey meters calibration. Part of this work is related to the characterization of the neutron source that will be used in the irradiator. Therefore, a source of 241Am-Be(α,n) was characterized according to the following attributes: neutron energy distribution, anisotropy and emission rate. In order to make these values into high-level metrological references traceable by the Bureau International des Poids et Mesures, these measurements were taken at the Neutron Laboratory part of the Laboratório Nacional de Metrologia das Radiações Ionizantes. Results obtained for the source spectrum have strong adherence to the reference spectrum established by ISO 8529-1. The new laboratory for neutron calibration will allow calibration in an approximate ambient dose equivalent ranging 20-4500 µSv/h.


Subject(s)
Alpha Particles , Americium/analysis , Americium/standards , Laboratories/standards , Radiation Monitoring/standards , Radiation Protection/standards , Radiation Dosage
3.
Radiat Prot Dosimetry ; 161(1-4): 185-9, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24625545

ABSTRACT

The Brazilian Metrology Laboratory of Ionizing Radiations (LNMRI) standard thermal neutron flux facility was designed to provide uniform neutron fluence for calibration of small neutron detectors and individual dosemeters. This fluence is obtained by neutron moderation from four (241)Am-Be sources, each with 596 GBq, in a facility built with blocks of graphite/paraffin compound and high-purity carbon graphite. This study was carried out in two steps. In the first step, simulations using the MCNPX code on different geometric arrangements of moderator materials and neutron sources were performed. The quality of the resulting neutron fluence in terms of spectrum, cadmium ratio and gamma-neutron ratio was evaluated. In the second step, the system was assembled based on the results obtained on the simulations, and new measurements are being made. These measurements will validate the system, and other intercomparisons will ensure traceability to the International System of Units.


Subject(s)
Radiation Protection/methods , Radiometry/instrumentation , Radiometry/methods , Americium , Beryllium , Brazil , Calibration , Carbon/chemistry , Computer Simulation , Equipment Design , Graphite/chemistry , Monte Carlo Method , Neutrons , Radiation Dosage , Radiation, Ionizing
4.
Ultrasound Obstet Gynecol ; 38(1): 107-15, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21465609

ABSTRACT

OBJECTIVE: To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra- and interobserver reliability and agreement with regard to endometrial measurement. METHODS: Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL(™)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A- and C-planes using subjective assessment. RESULTS: Endometrial volume measurements using the SMV and A-plane were more reliable (intra- and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra- and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra- and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or 'comparable' (50 and 53.3%, respectively), but never more difficult than using the C-plane. CONCLUSIONS: Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane.


Subject(s)
Endometrium/diagnostic imaging , Imaging, Three-Dimensional/methods , Adult , Endometrium/pathology , Female , Humans , Imaging, Three-Dimensional/classification , Observer Variation , Reproducibility of Results , Reproductive Techniques, Assisted , Ultrasonography , Young Adult
5.
Braz. j. med. biol. res ; 42(5): 426-432, May 2009. ilus, tab
Article in English | LILACS | ID: lil-511339

ABSTRACT

Subclinical hypothyroidism (SHT) is a disease for which exact therapeutic approaches have not yet been established. Previous studies have suggested an association between SHT and coronary heart disease. Whether this association is related to SHT-induced changes in serum lipid levels or to endothelial dysfunction is unclear. The aim of this study was to determine endothelial function measured by the flow-mediated vasodilatation of the brachial artery and the carotid artery intima-media thickness (IMT) in a group of women with SHT compared with euthyroid subjects. Triglycerides, total cholesterol, HDL-C, LDL-C, apoprotein A (apo A), apo B, and lipoprotein(a) were also determined. Twenty-one patients with SHT (mean age: 42.4 ± 10.8 years and mean thyroid-stimulating hormone (TSH) levels: 8.2 ± 2.7 µIU/mL) and 21 euthyroid controls matched for body mass index, age and atherosclerotic risk factors (mean age: 44.2 ± 8.5 years and mean TSH levels: 1.4 ± 0.6 µIU/mL) participated in the study. Lipid parameters (except HDL-C and apo A, which were lower) and IMT values were higher in the common carotid and carotid bifurcation of SHT patients with positive serum thyroid peroxidase antibodies (TPO-Ab) (0.62 ± 0.2 and 0.62 ± 0.16 mm for the common carotid and carotid bifurcation, respectively) when compared with the negative TPO-Ab group (0.55 ± 0.24 and 0.58 ± 0.13 mm, for common carotid and carotid bifurcation, respectively). The difference was not statistically significant. We conclude that minimal thyroid dysfunction had no adverse effects on endothelial function in the population studied. Further investigation is warranted to assess whether subclinical hypothyroidism, with and without TPO-Ab-positive serology, has any effect on endothelial function.


Subject(s)
Adult , Female , Humans , Brachial Artery/physiopathology , Carotid Arteries/physiopathology , Hypothyroidism/physiopathology , Tunica Intima/physiopathology , Tunica Media/physiopathology , Vasodilation/physiology , Brachial Artery/pathology , Brachial Artery , Case-Control Studies , Carotid Arteries/pathology , Carotid Arteries , Hypothyroidism/blood , Lipids/blood , Tunica Intima/pathology , Tunica Intima , Tunica Media/pathology , Tunica Media
6.
Braz J Med Biol Res ; 42(5): 426-32, 2009 May.
Article in English | MEDLINE | ID: mdl-19377791

ABSTRACT

Subclinical hypothyroidism (SHT) is a disease for which exact therapeutic approaches have not yet been established. Previous studies have suggested an association between SHT and coronary heart disease. Whether this association is related to SHT-induced changes in serum lipid levels or to endothelial dysfunction is unclear. The aim of this study was to determine endothelial function measured by the flow-mediated vasodilatation of the brachial artery and the carotid artery intima-media thickness (IMT) in a group of women with SHT compared with euthyroid subjects. Triglycerides, total cholesterol, HDL-C, LDL-C, apoprotein A (apo A), apo B, and lipoprotein(a) were also determined. Twenty-one patients with SHT (mean age: 42.4 +/- 10.8 years and mean thyroid-stimulating hormone (TSH) levels: 8.2 +/- 2.7 microIU/mL) and 21 euthyroid controls matched for body mass index, age and atherosclerotic risk factors (mean age: 44.2 +/- 8.5 years and mean TSH levels: 1.4 +/- 0.6 microIU/mL) participated in the study. Lipid parameters (except HDL-C and apo A, which were lower) and IMT values were higher in the common carotid and carotid bifurcation of SHT patients with positive serum thyroid peroxidase antibodies (TPO-Ab) (0.62 +/- 0.2 and 0.62 +/- 0.16 mm for the common carotid and carotid bifurcation, respectively) when compared with the negative TPO-Ab group (0.55 +/- 0.24 and 0.58 +/- 0.13 mm, for common carotid and carotid bifurcation, respectively). The difference was not statistically significant. We conclude that minimal thyroid dysfunction had no adverse effects on endothelial function in the population studied. Further investigation is warranted to assess whether subclinical hypothyroidism, with and without TPO-Ab-positive serology, has any effect on endothelial function.


Subject(s)
Brachial Artery/physiopathology , Carotid Arteries/physiopathology , Hypothyroidism/physiopathology , Tunica Intima/physiopathology , Tunica Media/physiopathology , Vasodilation/physiology , Adult , Brachial Artery/diagnostic imaging , Brachial Artery/pathology , Carotid Arteries/diagnostic imaging , Carotid Arteries/pathology , Case-Control Studies , Female , Humans , Hypothyroidism/blood , Lipids/blood , Tunica Intima/diagnostic imaging , Tunica Intima/pathology , Tunica Media/diagnostic imaging , Tunica Media/pathology , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...