1.
Med Phys ; 37(4): 1904-13, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20443512

ABSTRACT

PURPOSE: Previously, we demonstrated the potential of positron emission tomography detectors consisting of monolithic scintillation crystals read out by arrays of solid-state light sensors. We reported detector spatial resolutions of 1.1-1.3 mm full width at half maximum (FWHM) with no degradation for angles of incidence up to 30 degrees, energy resolutions of approximately 11% FWHM, and timing resolutions of approximately 2 ns FWHM, using monolithic LYSO:Ce3+ crystals coupled to avalanche photodiode (APD) arrays. Here we develop, validate, and demonstrate a simple model of the detector point spread function (PSF) of such monolithic scintillator detectors. METHODS: A PSF model was developed that essentially consists of two convolved components, one accounting for the spatial distribution of the energy deposited by annihilation photons within the crystal, and the other for the influences of statistical signal fluctuations and electronic noise. The model was validated through comparison with spatial resolution measurements on a detector consisting of an LYSO:Ce3+ crystal read out by two APD arrays. RESULTS: The model is shown to describe the measured detector spatial response well at the noise levels found in the experiments. In addition, it is demonstrated how the model can be used to correct the measured spatial response for the influence of the finite diameter of the annihilation photon beam used in the experiments, thus obtaining an estimate of the intrinsic detector PSF. CONCLUSIONS: Despite its simplicity, the proposed model is an accurate tool for analyzing the detector PSF of monolithic scintillator detectors and can be used to estimate the intrinsic detector PSF from the measured one.


Subject(s)
Positron-Emission Tomography/methods , Algorithms , Artifacts , Cerium/chemistry , Computer Simulation , Equipment Design/methods , Humans , Image Processing, Computer-Assisted/methods , Models, Statistical , Monte Carlo Method , Photons , Reproducibility of Results , Scattering, Radiation , Scintillation Counting , Transducers
2.
Phys Med Biol ; 54(7): 1893-908, 2009 Apr 07.
Article in English | MEDLINE | ID: mdl-19265203

ABSTRACT

We developed positron emission tomography (PET) detectors based on monolithic scintillation crystals and position-sensitive light sensors. Intrinsic depth-of-interaction (DOI) correction is achieved by deriving the entry points of annihilation photons on the front surface of the crystal from the light sensor signals. Here we characterize the next generation of these detectors, consisting of a 20 mm thick rectangular or trapezoidal LYSO:Ce crystal read out on the front and the back (double-sided readout, DSR) by Hamamatsu S8550SPL avalanche photodiode (APD) arrays optimized for DSR. The full width at half maximum (FWHM) of the detector point-spread function (PSF) obtained with a rectangular crystal at normal incidence equals approximately 1.05 mm at the detector centre, after correction for the approximately 0.9 mm diameter test beam of annihilation photons. Resolution losses of several tenths of a mm occur near the crystal edges. Furthermore, trapezoidal crystals perform almost equally well as rectangular ones, while improving system sensitivity. Due to the highly accurate DOI correction of all detectors, the spatial resolution remains essentially constant for angles of incidence of up to at least 30 degrees . Energy resolutions of approximately 11% FWHM are measured, with a fraction of events of up to 75% in the full-energy peak. The coincidence timing resolution is estimated to be 2.8 ns FWHM. The good spatial, energy and timing resolutions, together with the excellent DOI correction and high detection efficiency of our detectors, are expected to facilitate high and uniform PET system resolution.


Subject(s)
Positron-Emission Tomography/instrumentation , Sensitivity and Specificity , Time Factors