Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Am Heart J ; 249: 76-85, 2022 07.
Article in English | MEDLINE | ID: mdl-35472303

ABSTRACT

BACKGROUND: Screening for atrial fibrillation (AF) is attractive because AF independently raises the risk of ischemic stroke, this risk is largely reversible by long-term oral anticoagulant therapy (OAC), and many patients with AF remain undiagnosed and untreated. Recent trials of one-time brief screening for AF have not produced a significant increase in the proportion of patients diagnosed with AF. Trials of longer-term screening have demonstrated an increase in AF diagnoses, primarily paroxysmal AF. To date, however, no trials have demonstrated that screening for AF results in lower rates of stroke. Clinical practice guidelines conflict in their level of support for screening for AF. METHODS: The GUARD-AF individually randomized trial is designed to test whether screening for AF in individuals age 70 years or greater using a 2-week single-lead electrocardiographic patch monitor can identify patients with undiagnosed AF and lead to treatment with OAC, resulting in a reduced rate of stroke in the screened population. The trial's efficacy end point is hospitalization for stroke (either ischemic or hemorrhagic) and the trial's safety end point is hospitalization for a bleeding event. End points will be ascertained via Medicare claims or electronic health records at 2.5 years after study start. Enrollment is based in primary care practices and the OAC decision for screen-detected cases is left to the patient and their physician. The initial planned target sample size was 52,000, with 26,000 allocated to either screening or to usual care. RESULTS: Trial enrollment was severely hampered by the novel coronavirus disease 2019 (COVID-19) pandemic and stopped at a total enrollment of 11,931 participants. Of 5,965 randomized to the screening arm, 5,713 patients (96%) returned monitors with analyzable results. Incidence of screen-detected and clinically detected AF and associated stroke and bleeding outcomes will be ascertained. CONCLUSIONS: GUARD-AF is the largest AF screening randomized trial using a longer-term patch-based continuous electrocardiographic monitor. The results will contribute important information on the yield of patch-based AF screening, the "burden" of AF detected (percent time in AF, longest episode), and physicians' OAC decisions as a function of AF burden. GUARD-AF's stroke and bleed results will contribute to pooled trial analyses of AF screening, thereby informing future studies and guidelines.


Subject(s)
Atrial Fibrillation , COVID-19 , Stroke , Aged , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Electrocardiography , Hemorrhage/chemically induced , Humans , Medicare , Risk Factors , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , United States
2.
BMC Cardiovasc Disord ; 16: 35, 2016 Feb 17.
Article in English | MEDLINE | ID: mdl-26883019

ABSTRACT

BACKGROUND: Ambulatory electrocardiographic (ECG) monitoring is the standard to screen for high-risk arrhythmias. We evaluated the clinical utility of a novel, leadless electrode, single-patient-use ECG monitor that stores up to 14 days of a continuous recording to measure the burden and timing of potentially high-risk arrhythmias. METHODS: We examined data from 122,815 long term continuous ambulatory monitors (iRhythm ZIO® Service, San Francisco) prescribed from 2011 to 2013 and categorized potentially high-risk arrhythmias into two types: (1) ventricular arrhythmias including non-sustained and sustained ventricular tachycardia and (2) bradyarrhythmias including sinus pauses >3 s, atrial fibrillation pauses >5 s, and high-grade heart block (Mobitz Type II or third-degree heart block). RESULTS: Of 122,815 ZIO® recordings, median wear time was 9.9 (IQR 6.8-13.8) days and median analyzable time was 9.1 (IQR 6.4-13.1) days. There were 22,443 (18.3%) with at least one episode of non-sustained ventricular tachycardia (NSVT), 238 (0.2%) with sustained VT, 1766 (1.4%) with a sinus pause >3 s (SP), 520 (0.4%) with a pause during atrial fibrillation >5 s (AFP), and 1486 (1.2%) with high-grade heart block (HGHB). Median time to first arrhythmia was 74 h (IQR 26-149 h) for NSVT, 22 h (IQR 5-73 h) for sustained VT, 22 h (IQR 7-64 h) for SP, 31 h (IQR 11-82 h) for AFP, and 40 h (SD 10-118 h) for HGHB. CONCLUSIONS: A significant percentage of potentially high-risk arrhythmias are not identified within 48-h of ambulatory ECG monitoring. Longer-term continuous ambulatory ECG monitoring provides incremental detection of these potentially clinically relevant arrhythmic events.


Subject(s)
Atrioventricular Block/epidemiology , Bradycardia/epidemiology , Sinus Arrest, Cardiac/epidemiology , Tachycardia, Ventricular/epidemiology , Aged , Aged, 80 and over , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Atrioventricular Block/diagnosis , Bradycardia/diagnosis , Cohort Studies , Electrocardiography, Ambulatory , Female , Heart Block/diagnosis , Heart Block/epidemiology , Humans , Incidence , Male , Middle Aged , Retrospective Studies , Sinus Arrest, Cardiac/diagnosis , Tachycardia, Ventricular/diagnosis , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...