Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Int J Cardiol ; 370: 222-228, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36243181

ABSTRACT

BACKGROUND: Clinical effects of rate-adaptive pacing (RAP) are unpredictable and highly variable among cardiac resynchronization therapy (CRT) patients with chronotropic incompetence. Physiologic sensors such as Closed Loop Stimulation (CLS), measuring intracardiac impedance changes (surrogate for ventricular contractility), may add clinical benefit and help identify predictors of response to RAP. The objective of the present BIOlCREATE study subanalysis was to identify criteria for selection of CRT patients who are likely to respond positively to CLS-based RAP. METHODS: In the randomized, crossover BIO|CREATE study, CRT patients with severe chronotropic incompetence and NYHA class II/III were randomized to CLS with conventional upper sensor rate programming or to no RAP for 1 month, followed by crossover for another month. At 1-month and 2-month follow-ups, patients underwent treadmill-based cardiopulmonary exercise test. Positive CLS response was defined as a ≥ 5% reduction in ventilatory efficiency slope. Eight of 17 patients (47%) were CLS responders. In this subanalysis, we compared responders and non-responders to explore outcomes, mechanisms, and predictors. RESULTS: All cardiopulmonary variables, health-related quality of life, patient activity status, and NT-proBNP concentration showed favorable trend in CLS responders and unfavorable trend in non-responders, underlining the need to find predictors. Following all analyses, we recommend CLS in heart failure patients with improved left ventricular ejection fraction (LVEF >40%, after a ≥ 10-point increase from a CRT-pre-implant value of ≤40%), corresponding to 'HFimpEF' in the universal classification system. CONCLUSION: HFimpEF patients are likely to benefit from CLS-based RAP, in contrast to 'HFrEF' (heart failure with reduced LVEF [≤40%]).


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Stroke Volume , Ventricular Function, Left , Quality of Life , Heart Failure/diagnosis , Heart Failure/therapy , Arrhythmias, Cardiac/therapy , Chronic Disease , Treatment Outcome
3.
Europace ; 23(11): 1777-1786, 2021 11 08.
Article in English | MEDLINE | ID: mdl-33982093

ABSTRACT

AIMS: Clinical effects of rate-adaptive pacing in heart failure patients with chronotropic incompetence (CI) undergoing cardiac resynchronization therapy (CRT) remain unclear. Closed loop stimulation (CLS) is a new rate-adaptive sensor in CRT devices. We evaluated the effectiveness of CLS in CRT patients with severe CI, focusing primarily on key prognostic variables assessed by cardiopulmonary exercise (CPX) testing. METHODS AND RESULTS: In the randomized, crossover, multicentre BIO|CREATE study, 20 CRT patients with severe CI and NYHA Class II/III (60%/40%) were randomized 1:1 to the sequence DDD-40 mode to DDD-CLS mode, or the sequence DDD-CLS mode to DDD-40 mode (1 month in each mode). Patients underwent symptom-limited treadmill-based CPX test in each mode. An improvement (decrease) of the ventilatory efficiency (VE) slope of ≥5% during CLS was regarded as positive response to CLS. Seventeen patients with full data sets had a mean intra-individual VE slope change of -1.8 ± 3.0 (-4.1%) with CLS (P = 0.23). Eight patients (47%) were CLS responders, with a -6.1 ± 2.7 (-16.4%) slope change (P = 0.029). Compared to non-responders, CLS responders had a higher left ventricular (LV) ejection fraction (46 ± 3 vs. 36 ± 9%; P = 0.0070), smaller end-diastolic LV volume (121 ± 34 vs. 181 ± 41 mL; P = 0.0085), smaller end-systolic LV volume (65 ± 23 vs. 114 ± 39 mL; P = 0.0076), and were predominantly in NYHA Class II (P = 0.0498). CONCLUSION: The data of the present pilot study are compatible with the notion that CLS activation may improve VE slope in CRT patients with severe CI and less advanced heart failure. Further research is needed to determine the long-term clinical outcomes of CLS.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Cardiac Resynchronization Therapy/methods , Cross-Over Studies , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Pilot Projects , Prognosis , Treatment Outcome
4.
Europace ; 23(5): 722-730, 2021 05 21.
Article in English | MEDLINE | ID: mdl-33351076

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the gold standard for atrial fibrillation (AF) ablation. Recently, catheter ablation targeting rotors or focal sources has been developed for treatment of AF. This study sought to compare the safety and effectiveness of Focal Impulse and Rotor Modulation (FIRM)-guided ablation as the sole ablative strategy with PVI in patients with paroxysmal AF. METHODS AND RESULTS: We conducted a multicentre, randomized trial to determine whether FIRM-guided radiofrequency ablation without PVI (FIRM group) was non-inferior to PVI (PVI group) for treatment of paroxysmal AF. The two primary efficacy end points were (i) acute success defined as elimination of AF rotors (FIRM group) or isolation of all pulmonary veins (PVI group) and (ii) long-term success defined as single-procedure freedom from AF/atrial tachycardia (AT) recurrence 12 months after ablation. The study was closed early by the sponsor. At the time of study closure, any pending follow-up visits were waived. A total of 51 patients (mean age 63 ± 10.6 years, 57% male) were enrolled. All PVs were successfully isolated in the PVI group and all rotors were successfully eliminated in the FIRM group. Single-procedure effectiveness was 31.3% (5/16) in the FIRM group and 80% (8/10) in the PVI group at 12 months. Three vascular access complications occurred in the FIRM group. CONCLUSION: These partial study effectiveness results reinforce the importance of PVI in paroxysmal AF patients and indicate that FIRM-guided ablation alone (without PVI) is not an effective strategy for treatment of paroxysmal AF in most patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
5.
Herzschrittmacherther Elektrophysiol ; 30(2): 191-196, 2019 Jun.
Article in German | MEDLINE | ID: mdl-31001686

ABSTRACT

INTRODUCTION: Due to improved treatment of heart failure, patients are older and have more comorbidities at the time of an elective device exchange. This leads to higher rates of complications and represents an opportunity for re-evaluation of the implantable cardioverter defibrillator (ICD) treatment. OBJECTIVE: This article reviews the current literature regarding the indications for continued ICD therapy and device exchange in patients who have never received adequate treatment through the ICD. MATERIAL AND METHODS: Patients with primarily prophylactic indications, who have not received adequate treatment and have shown significant improvement in the left ventricular ejection fraction (LVEF) >35%, have a significantly lower risk of ventricular arrythmia (VA) after device exchange. Although further ventricular events can occur in these patients, the continuation of ICD treatment should be individually discussed in cases of high age and increased comorbidities. In female patients with a non-ischemic cardiac myopathy and an almost normalized LVEF, mostly during cardiac resynchronization therapy (CRT), a discontinuation of ICD treatment or downgrading to CRT with pacemaker (CRT-P) treatment should be discussed. CONCLUSION: At the time of an elective device exchange for primarily prophylactic indications, the possibility to discontinue ICD treatment can be discussed with patients who have not experienced adequate treatment. Additional factors, such as LVEF, age, sex and comorbidities of the patient should be taken into consideration in order to make an individualized decision. As prospective randomized studies are lacking, it is not possible to give generally valid recommendations.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Prospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...